Download DriveWare User Manual
Transcript
26 To modify drive specifications, click on the desired item. Select new values from the drop-down lists or type the new value to the field. You can see the input fields for drive load specifications in Table 7. Table 7. Drive load specifications Specification Options Name Any text or number string. This will also show up in reports and, depending on the Tools/Options settings, on screen. Inverter amount Number of similar drives with range 1 – 100 for one branch in the System configuration tree Type Air cooled, Cold plate IP class Not specified IP20 – This selection means that the user is specifically limiting the choices to the IP20 protection class. Switching frequency 4, 8, 16 kHz. Higher switching frequency will reduce the audible noise and give better motor performance, but will adversely cause losses in the drive and the max current providing capability. Braking chopper Ignored – This selection means that even though the internal chopper is used, the losses of it are anyway ignored when a drive selection is performed. Internal – This selection means that the losses of internal chopper are added to drive losses and the limitations of the internal chopper are considered when selecting a drive. Braking resistor Not considered – The braking resistor is not selected this time. Selected – The braking resistor is selected on the basis of the motion duty braking power requirements. Sizing