Download 1. Control Panel Firmware Replacement
Transcript
SATEL VERSA 19 Configuration – button opens the "Configuration" window. Connection – button opens the drop-down menu, where you can select the method of establishing communication between the program and the alarm control panel. Fig. 4. Menu displayed after pressing the 2.2.2 button. Changing the program access code 1. Open the FILE menu, select ACCESS SETUP and then CHANGE ACCESS CODE (see: Fig. 5). Fig. 5. Functions related to the access to DLOADX program. 2. Enter your present access code to the program and click on the "OK" button. 3. Enter the new access code to the program and click on the "OK" button. 4. Re-enter the new program access code and click on the "OK" button. The program allows you to obtain access, based on additional access codes, which can be defined and for which the authority level can be defined (FILE ACCESS SETUP PROGRAM USERS – see: Fig. 5). 2.2.3 Parameters related to programming by means of the DLOADX program In case of remote programming, it is necessary to configure some communication parameters and options in the control panel. In case of local programming without verification of identifiers, the parameters described below may be configured after communication with the control panel is established.