Download 1. Control Panel Firmware Replacement

Transcript
20
Programming Manual
SATEL
Identifiers
The identifiers can be programmed:
– in the DLOADX program, "Identifiers and tel. no" window. The command for opening
this window is available in the COMMUNICATION menu. You can also open it by using
the Ctrl+R key combination.
– in the keypad, 0. SRVMOD CONFIG submenu.
VERSA identifier – identifier of the alarm control panel which makes it possible to
identify the control panel and match the data file to it, provided that the data file has
been saved on the computer. It consists of 8 hexadecimal characters (digits or letters
from A to F). The same identifier must not be programmed for different control panels
operated from the same computer (the DLOADX program will be incapable of
distinguishing between them).
DLOADX identifier – identifier of the computer with DLOADX program. If communication
is effected, including verification of identifiers, the control panel will only establish
connection with the program which uses the valid identifier. It consists of 8
hexadecimal characters (digits or letters from A to F).
Note: In case of establishing communication with the alarm system whose identifiers
have factory defaults (00000000), the DLOADX program will suggest random
generated identifiers.
Telephone communication parameters
The telephone numbers are programmed in:
– DLOADX program, "Identifiers and tel. no" window;
– keypad, 0. SRVMOD CONFIG submenu (only computer telephone number).
The number of rings is programmed in:
– DLOADX program, "Global parameters" window;
– keypad, 7. ANSWERING submenu.
Options related to remote programming via the modem (e.g. ANSWERING – MODEM and
DOUBLE CALL) are described in Section GLOBAL OPTIONS.
VERSA panel telephone number – telephone number of the control panel. Available
for programming only in DLOADX program.
PC telephone number – telephone number of the computer from which the control
panel is to be programmed. It should be programmed if the telephone connection is
to be made by the control panel (the panel initiates the connection or calls back).
Rings before answer – number of rings after which the control panel will go off hook.
Parameters of communication via Ethernet (TCP/IP) network
The IP address of computer with DLOADX program (SERVER), TCP port for
communication through Ethernet network, encryption key (DLOADX KEY) and the
DLOADX->ETHM-1 CONNECTION option are programmed for the ETHM-1 module (see:
section ETHM-1 ETHERNET MODULE – p. 47):
– in the "Versa – Structure" window, "Hardware" tab, after the ETHM-1 module has
been selected in the list;
– in the keypad, by means of the SETTINGS function (SERVICE MODE 2. HARDWARE
1. KPDS. & EXPS. 2. SETTINGS), after the ETHM-1 module has been selected from
the list that will be displayed (the programming is effected by the "step by step"
method).