iVu Plus Industrial Ethernet
1 Device Setup
1.1 Set IP Address
When shipped, the device is assigned a default IP address - 192.168.0.1, a default Subnet Mask - 255.255.255.0, and a
default gateway - 0.0.0.0. To change these defaults, click on Main Menu > System > Communications > Ethernet
I/O.
1.2 Set Industrial Ethernet Protocol (EIP/Modbus/TCP/PCCC)
The Industrial Ethernet communication channel is disabled by default. In order to enable this channel, click on Main Menu
> System > Communications > Industrial Ethernet > Connection. Select the channel of interest (EIP, Modbus/TCP
or PCCC). Only one type of connection can be established at any given time.
Information about an established connection can be obtained from Main Menu > System > Communications >
Industrial Ethernet > Status screen. Click on the connection of interest to view details.
This device provides extensive logging for the communication that occurs over the Industrial Ethernet connection. Logs can
either be viewed from Main Menu > System > Communications > Industrial Ethernet > View Logs, or Main Menu
> Logs > Communication Logs > Industrial Ethernet.
1.3 Set Trigger Mode
The sensor can be triggered using either the hardware trigger or through over the Industrial EtherNet. In order to only
accept triggers generated through the Industrial EtherNet communication channel, click on the Main Menu > Imager >
Trigger, and select Industrial EtherNet Only from the drop-down menu.