iVu Plus BCR User's Manual 9.5 Modbus/TCP The Modbus/TCP protocol provides device control using register and coil banks defined by the slave device. This section defines the iVu Plus Modbus/TCP register and coil banks. From the point of view of the slave device (PLC), there is one output coil registers and two Input Coil registers. The bits in the Output Coil Registers cause actions to occur. The corresponding ACK bits in the Input Coil register get set when the action is complete. The Status Coil register provides status of certain system states. By specification, Modbus/TCP uses TCP port 502. Note that the output coils correspond to the Output and ACK Flags, and the input coils correspond to the Input Flags. Modbus Function Codes Supported: 01: Read Coil Status 02: Read Input Status 03: Read Holding Registers 04: Read Input Registers 05: Force Single Coil 06: Preset Single Register 07: Read Exception Status 15: Write Multiple Coils 16: Preset Multiple Registers 124 www.bannerengineering.com - tel: 763-544-3164 Rev. B