Download VISTA-40

Transcript
VISTA-40 SINGLE PARTITION PROGRAMMING FORM
✱54 -✱57
✱58
ALARM REPORT CODE & ID DIGITS FOR ZONES
1-16. Skip these fields. Use #93 Menu Mode,
Zone Programming to assign report codes.
SUPV. & RESTORE CODES for zones 1-16
|
Alarm Rst.
|
Trouble
|
Trble Rst.
|
Bypass
|
Bypass Rst.
✱59 -✱62
✱63
Open
|
|
Low Battery
|
|
Low Bat Res
|
|
AC Loss
|
|
AC Restore
|
|
Test
|
|
Power
|
|
Cancel
|
|
Prog. Tamp.
|
|
ALARM REPORT CODE & ID DIGITS FOR ZONES
17-32. Skip these fields. Use #93 Menu Mode,
Zone Programming to assign report codes.
SUPV. & RESTORE CODES for zones 17-32
|
Alarm Rst.
|
Trouble
|
Trble Rst.
|
Bypass
|
Bypass Rst.
✱64
SYSTEM NON ALARM CODES
✱8 1
✱8 2
First Digit Second Digit
Close
|
|
✱8 3
Second digit of each
code applies only to
4+2 or expanded (fields
✱52 & ✱53) formats.
FIRST TEST REPORT TIME
|
|
|
[Day 00; hour 12; min 00] Days 01-07 Hours 00-23 Min 00-59;
00 in all boxes=instant (Day 01= Monday)
✱8 4
SWINGER SUPPRESSION
[03]
|
01-15 alarms ; Must be "00" (disabled) for UL.
✱8 5
ENABLE DIALER REPORTS
FOR PANICS & DURESS
95
96
99
Duress
1=enable; 0=disable
- ✱67 ALARM REPORT CODE & ID DIGITS FOR ZONES
33-48. Skip these fields. Use #93 Menu Mode,
Zone Programming to assign report codes.
✱ 86
4208 MODULE ZONE ASSIGNMENT
1=allows 8 zone numbers (10-17) on one module, but prevents any
other polling loop expansion; 0=Otherwise
✱8 7
ENTRY WARNING
[1]
1=continuous; 0=3 beeps
✱68
SUPV. & RESTORE CODES for zones 33-48
|
✱8 8
BURG. ALARM COMM. DELAY
✱8 9
RESTORE REPORT TIMING
✱9 0
2nd SUBS. ACCT #
Alarm Rst.
1=16 seconds; 0=no delay
|
Trouble
|
Trble Rst.
|
Bypass
|
Bypass Rst.
0=instant; 1=at bell timeout; 2=at disarm
Enter 00-09; B-F (11-15)
|
✱ 74-✱ 77
ALARM REPORT CODE & ID DIGITS FOR ZONES
49-99. Skip these fields. Use #93 Menu Mode,
Zone Programming to assign report codes.
Trouble
|
Trouble
|
Trble Rst.
|
Trble Rst.
|
Bypass
|
Bypass
|
Bypass Rst.
|
Bypass Rst.
1=immediate; 0=when disarmed; Must be "1" for UL
1 ✱ 2 9 RF TX LOW BATTERY REPORT ENABLE
1✱3 0
RF RCVR CHECK-IN INTERVAL
1 ✱ 3 1 RF TRANSMITTER CHECK-IN INTERVAL[12]
02-15 times 2 hours; 00 disables transmitter supervision
Max. "6" (12 hr) for UL
1 ✱ 3 2 RF RECEIVER TYPE
1=4281 ; 2=5881; 0=NONE
1 ✱ 3 3 TOUCH-TONE W/ROTARY BACKUP ENABLE
1=enable; 0=disable
4
5
6
7
8
[06]
|
02-15 times 2 hours; 00 disables supervision
Max. "6" (12 hr) for UL
ZONE TYPE RESTORE ENABLES 1=enable; [0=disable]
✱ 7 9 FOR ZONE TYPES 1-8
✱80 ZONE TYPES 9/10
3
✱94)
1✱01 - 1✱09 ASSIGN RESPONSE TYPE FOR ZONES
Skip these fields. Use #93 Menu Mode, Zone
Programming to assign response types
1=enable; 0=disable Must be "1" for UL
|
2
|
1 ✱ 2 8 RF TX LOW BATTERY SOUND
SUPV. & RESTORE CODES
✱ 73 (for zones 49-64)
✱ 78 (for zones 87-99)
|
Alarm Rst.
|
Alarm Rst.
1
|
2nd Page Programming Fields
(press
✱ 69 -✱ 72,
|
[15 15 15 15]
9
10
Page 5
|