Download VISTA-40
Transcript
VISTA-40 SINGLE PARTITION PROGRAMMING FORM ✱54 -✱57 ✱58 ALARM REPORT CODE & ID DIGITS FOR ZONES 1-16. Skip these fields. Use #93 Menu Mode, Zone Programming to assign report codes. SUPV. & RESTORE CODES for zones 1-16 | Alarm Rst. | Trouble | Trble Rst. | Bypass | Bypass Rst. ✱59 -✱62 ✱63 Open | | Low Battery | | Low Bat Res | | AC Loss | | AC Restore | | Test | | Power | | Cancel | | Prog. Tamp. | | ALARM REPORT CODE & ID DIGITS FOR ZONES 17-32. Skip these fields. Use #93 Menu Mode, Zone Programming to assign report codes. SUPV. & RESTORE CODES for zones 17-32 | Alarm Rst. | Trouble | Trble Rst. | Bypass | Bypass Rst. ✱64 SYSTEM NON ALARM CODES ✱8 1 ✱8 2 First Digit Second Digit Close | | ✱8 3 Second digit of each code applies only to 4+2 or expanded (fields ✱52 & ✱53) formats. FIRST TEST REPORT TIME | | | [Day 00; hour 12; min 00] Days 01-07 Hours 00-23 Min 00-59; 00 in all boxes=instant (Day 01= Monday) ✱8 4 SWINGER SUPPRESSION [03] | 01-15 alarms ; Must be "00" (disabled) for UL. ✱8 5 ENABLE DIALER REPORTS FOR PANICS & DURESS 95 96 99 Duress 1=enable; 0=disable - ✱67 ALARM REPORT CODE & ID DIGITS FOR ZONES 33-48. Skip these fields. Use #93 Menu Mode, Zone Programming to assign report codes. ✱ 86 4208 MODULE ZONE ASSIGNMENT 1=allows 8 zone numbers (10-17) on one module, but prevents any other polling loop expansion; 0=Otherwise ✱8 7 ENTRY WARNING [1] 1=continuous; 0=3 beeps ✱68 SUPV. & RESTORE CODES for zones 33-48 | ✱8 8 BURG. ALARM COMM. DELAY ✱8 9 RESTORE REPORT TIMING ✱9 0 2nd SUBS. ACCT # Alarm Rst. 1=16 seconds; 0=no delay | Trouble | Trble Rst. | Bypass | Bypass Rst. 0=instant; 1=at bell timeout; 2=at disarm Enter 00-09; B-F (11-15) | ✱ 74-✱ 77 ALARM REPORT CODE & ID DIGITS FOR ZONES 49-99. Skip these fields. Use #93 Menu Mode, Zone Programming to assign report codes. Trouble | Trouble | Trble Rst. | Trble Rst. | Bypass | Bypass | Bypass Rst. | Bypass Rst. 1=immediate; 0=when disarmed; Must be "1" for UL 1 ✱ 2 9 RF TX LOW BATTERY REPORT ENABLE 1✱3 0 RF RCVR CHECK-IN INTERVAL 1 ✱ 3 1 RF TRANSMITTER CHECK-IN INTERVAL[12] 02-15 times 2 hours; 00 disables transmitter supervision Max. "6" (12 hr) for UL 1 ✱ 3 2 RF RECEIVER TYPE 1=4281 ; 2=5881; 0=NONE 1 ✱ 3 3 TOUCH-TONE W/ROTARY BACKUP ENABLE 1=enable; 0=disable 4 5 6 7 8 [06] | 02-15 times 2 hours; 00 disables supervision Max. "6" (12 hr) for UL ZONE TYPE RESTORE ENABLES 1=enable; [0=disable] ✱ 7 9 FOR ZONE TYPES 1-8 ✱80 ZONE TYPES 9/10 3 ✱94) 1✱01 - 1✱09 ASSIGN RESPONSE TYPE FOR ZONES Skip these fields. Use #93 Menu Mode, Zone Programming to assign response types 1=enable; 0=disable Must be "1" for UL | 2 | 1 ✱ 2 8 RF TX LOW BATTERY SOUND SUPV. & RESTORE CODES ✱ 73 (for zones 49-64) ✱ 78 (for zones 87-99) | Alarm Rst. | Alarm Rst. 1 | 2nd Page Programming Fields (press ✱ 69 -✱ 72, | [15 15 15 15] 9 10 Page 5 |