Download USER MANUAL

Transcript
current value set with the knob until the gassing voltage of the battery is reached
(14.4V for 12V battery, 28.8V for 24V battery). Then charging current is
automatically limited to the value necessary to sustain this voltage. So there is no
risk of overloading the battery.
4. TECHNICAL SPECIFICATIONS
Table 1
Item
Parameter
1
2
1. Power supply (single-phase)
2. Frequency
3. Welding current:
P30%
P60%
P100%
4. Current Range - Welding
5. Current Range - Charging
6. Input current:
P30%
P60%
P100%
7. Output Power:
P30%
P60%
P100%
8. Power factor (150A)
9. Open Circuit Voltage
10. Power cable cross-section
11. Case Enclosure Class
12. Insulation class
Length
13. Dimensions:
Width
Height
14. Weight
15. Compliance with Standard
3
Unit
3
V
Hz
A
A
A
A
kVA
V
mm2
mm
mm
mm
kg
Value
4
220-230
50/60
150
110
100
5-150
1-30
32
22
20
7.0
4.8
4.4
0.7
90
3x2.5
IP22
F
240
190
210
6.5
EN 60974-1