Download Philips 202p7
Transcript
DDC Instructions 202P7 CRT 27 Go to cover page 2. Access Factory Mode 1). Turn off monitor(don't turn off PC) 2). Press and simultaneously on the front control pane, then press , wait until the OSD menu with characters P72 FAMILY V0.10 20050104 (below OSD menu) come on the screen of monitor (see Fig. 23). Factory Mode------------Indicator Step 6: Save DDC data Sometimes, you may need to save DDC data as a text file for using in other IC chip. To save DDC data, follow the steps below: 1. Click (Save) icon (or click "file"-> "save as") from the tool bar And give a file name as shown in Fig. 25. The file type is EDID46 file (*.ddc) which can be open in WordPad. By using WordPad, the texts of DDC data & table (128 bytes, hex code) can be modified. If DDC TEXTS & HEX Table are completely correct, it can be saved as .ddc flie to re-load it into DDC IC for DDC Data application. Fig. 25 2. Click Save. Fig. 23 3). Push "Menu" to exit OSD menu. 4). Click (Write EDID) icon from the tool bar to write DDC data,wait for 10-15 seconds ,DDC data will be finished Writing. Step 7: Exit DDC program Pull down the File menu and select Exit as shown in Fig. 26. 3. Confirm Serial Number in User Mode 1) Press the button to turn off the monitor. Press the button again to turn on the monitor. 2) Press the button to bring up the OSD main menu. 3) Press the button to select Extra Controls, press the button to confirm your selection. 4) Confirm the Serial Number ''TY 001440'' is updated as shown in Fig. 24. Fig. 26 Step 8: Turn off the monitor, exit the factory mode. Fig.24