Download Installation / Troubleshooting Manual

Transcript
V. Pre-Startup:
Prime the fuel system. If you have an electric priming or boost pump, circulate fuel for 10 minutes while checking for leaks. If not, use
the engines manual pump. Before starting, open the lift pumps’ outlet fitting slightly. Before start-up, verify that all fuel system
fittings are tight.
VI. System Start-Up:
Start and run your engines. Look for leaks and other installation problems. If system is not operating properly refer to the
Troubleshooting Instructions and correct any deficiencies.
VII. Calibration:
When system is running properly, refer to the calibration instructions and calibrate your system. If installed properly, initial calibration
takes less than 1 hour. After consuming some fuel, final calibration should only take a few minutes.
USCG approved fuel hose with either fabric or wire reinforcing braid meet the following standards:
Hose Marking
USCG Type A-1
USCG Type A-2
USCG Type B-1
USCG Type B-2
Permeation Rating
100g/m²/24hrs.
300g/m²/24hrs.
100g/m²/24hrs.
300g/m²/24hrs.
2½ Minute Fire Test
Required
Required
Not Required
Not Required
Table I
12/8/2004
FloScan Instrument Company, Inc.
3016 NE Blakeley Street, Seattle, WA 98105
7000-339-00
Tel: (206) 524-6625
Fax: (206) 523-4961
email: [email protected] http://www.floscan.com