Download TouchWare for Windows User's Guide
Transcript
54 TouchWare for Windows User's Guide Additional ThruGlass Specific Commands These commands can be used for diagnostics and configuration of ThruGlass controllers. Table 3: ThruGlass Specific Controller Commands Command Name ASCII Code Description Mode Noise Extended Mode Set Creep Set Sensitivity MN MX SC [pressed released] SS [max/min adjacent unused speed fast level release] SF [freq] SP [resln delay] ST [0..3] SCX [xtbl|X0 X1 X2 X3 X4 X5 X6 X7] SCY [ytbl|Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7] FRA FBA FZA NOA Stream noise data packets Send firmware algorithm data on press Set/show base update rates Set/show touch algorithm parameters Set Frequency Set Phase Set Type Set Correction X Set Correction Y Format Raw ASCII Format Base ASCII Format Depth ASCII Noise ASCII Set/show frequency Set/show phase Set/show controller & screen orientation Set/show X depth correction parameters Set/show Y depth correction parameters Show 16 sensor channel values Show 16 base values Show 16 press depth values Show noise data ThruGlass Command Line Commands Sending ESCAPE,ESCAPE,ESCAPE will place the ThruGlass controller into ‘terminal’ mode. The following commands are then active. Note that some parameter values can render the controller inoperative. FR will return the controller to factory default settings. Note that these commands are for diagnostic use only and are not recommended for normal operation. • Enter either full command or abbreviation followed by <ENTER>. • Angle brackets indicate required parameter. • Square brackets indicate optional parameter(s). • Vertical bar indicates a choice must be made from list.