CPC
March 1999
New test pulse functions have been implemented. This is in V3, as well in the modified V2. The
external testpulse, running on the JTAG cable, is now also available on the Read Out Controller
(IC7). And there is a connection, running from the ROC (Read Out Controller) to the Control-Mach
(IC3). This makes it possible to generate test pulses to the TDCs and majority inputs from the ROC.
From the external testpulse, the ROC can generate a trigger to the TDCs with a fixed delay in respect
of the TDC’s input pulses. The feature is added for testing purposes.
This test pulse must be enabled in the Control-Mach (see Table 5, control register). Though the
definition of the control register has changed, it is compatible with older routines, choosing between
the previously existing test pulse sources.
Modified V2 cards can easily be recognized by the copy of the serial number on the back side of the
RJ45 connector and the yellow connect LED, which used to be red. The serial numbers of V2 range
from x011 until x04c and the serial numbers for V3 start at x051.
page 5