HI 2151 Series Weight Controller
Profibus Interface Option
4.7
SET POINT STATUS/DESCRIPTION BYTES
4.7.1
NOTE:
SET POINT STATUS
Relay 8
Relay 7
Relay 6
Relay 5
Relay 4
Relay 3
Relay 2
Relay 1
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Relays 1 and 2 are swapped on bits 6 and 7 for set point status.
4.7.2
1.
SET POINT DESCRIPTION
The set point value is the target weight or level. The set points can be set to track
peak, gross, net, rate-of-change (ROC) or total. Here is a description of the set point
mode selection:
Peak
Gross
Net
ROC
Total
0
1
2
3
4
Example:
The proper set point description bytes for the desired Relay types are as follows :
Relays
Relay 1 = Gross
Relay 2 = Net
Relay 3 = ROC
(Rate-of-Change)
LSB/MSB
0102
0300
Relay 4 = Peak
Relay 5 = Total
Relay 6 = Gross
Relay 7 = Gross
Relay 8 = Gross
18
0401
0101
.