Download User's Manual
Transcript
SINE SAVER User’s Manual SINE SAVER Trouble Shooting Guide Symptom Cause Remedy LCD backlight does not Input power wiring not Check input power wiring, refer to SINE SAVER illuminate. connected properly. Electrical Installation Diagram. Input voltage not within Measure the input voltage at SINE SAVER input specification. terminals. Check with specifications. No 24VDC supply Check output of SMPS No line current. Enable signal is not active. Check that the EN terminal is connected to +5V Check that the ENABLED message is displayed. V LIMIT message appears continuously. Input voltage has exceeded maximum rating. See SINE SAVER General Specifications for input voltage ratings. OPT SC message appears Hardware level protection in power stack activated. Check power components OC Line current was greater than SINE SAVER’s maximum current. Check system current ratings. OV message appears. Input voltage has exceeded maximum ratings. See general specification and check the input is within ratings. Ventilation problem. Ensure operating ambient temperature is within specification. OT message. Check input supply for voltage transients. Fix the external source. Check fans are rotating freely and there is no build up of dust or debris in blades. Visually examine the heatsink fins for build up of dust and debris. System is constantly overloaded. Check SINE SAVER continuous ambient temperature rating. IM00097B current and Page 25