Download Tecumseh VSAG529ZXTHM Performance Data Sheet

Transcript
VSAG529ZXTHM
TPC___preliminary
October 14, 2011
TECUMSEH HERMETIC
CONDENSING UNIT
Model
BOM
Air Cooled
Application
Refrigerant
VSAG529ZXTHM
32L7242-2E
7 ¼ HP
Low Temp
R404A
47.75
46.97
31.58
29.00
26.00
4.50
SUCTION 7/8"
LIQUID 1/2"
Dim. Enclosure(inch)*
VSAG529ZXTHM
L
W
29.40 47.75
*) Enclosure Mounting Holes, 26.25 x 58.5
Line connections
H
Suction
Liquid
31.58
7/8 Sweat
1/2 Sweat
Pumpdown
o
90% @ 90 F
37.69
Air flow
Oil Ch.
Gross weight
SCFM
Oz.
Lbs.
4200
24
600
Factory charge 20 psig dry air, MUST BE EVACUATED
Evaporator
T, °F
-40
-35
-30
-25
-20
-15
-10
-5
0
5
10
PSIG
5.5
8.0
10.7
14.0
17.1
19.3
24.5
28.8
33.5
36.5
43.7
BTUH
13400
15300
17400
19800
22400
25100
28000
31100
34200
37400
40700
85°F
Watts Head
4760
218
4890
222
5040
226
5200
231
5370
236
5550
241
5750
247
5960
253
6190
259
6440
265
6710
272
o
Cond T
94
96
97
99
100
102
103
105
107
108
110
BTUH
12700
14400
16200
18400
20700
23200
25900
28600
31500
34500
37600
Ambient Temperatures
95°F
100°F
Watts Head Cond T BTUH Watts Head
5270
251
104
12400 5570
269
5390
255
105
13900 5690
273
5530
259
107
15700 5810
277
5670
263
108
17700 5950
281
5830
268
109
19900 6110
286
6010
273
110
22300 6280
291
6200
279
112
24900 6470
296
6410
285
113
27600 6680
302
6640
291
115
30400 6910
308
6900
297
117
33200 7160
315
36100 7430
322
7170
304
118
Cond T
109
110
111
112
114
115
116
118
119
121
122
BTUH
10900
12200
13800
15600
17700
19900
22200
24700
27300
30000
32700
110°F
Watts Head
6240
307
6330
310
6440
313
6570
317
6710
321
6870
326
7050
331
7250
337
7470
343
7720
350
7990
357
Cond T
119
120
120
121
122
124
125
126
127
129
130
o
Performance @ 60 Hz, Return gas 40 F, SubCooling 5 F
PRELIMINARY PERFORMANCE DATA
L:\~ Andreea temp\ZZ Low Temp Scroll Datasheets\WORD_datasheets\Outdoor units\VSAG529ZXTHM_preliminary.doc
14/10/2011
VSAG529ZXTHM
TPC___preliminary
October 14, 2011
Parts/Specifications
STANDARD
Unit BOM
Unit MODEL
32L7242-2E
VSAG529ZXTHM
Refrigeration RANGE
Design Pressure Low
Design Pressure High
Volts - HZ - Ph
Voltage Range
Min. Circuit Ampacity
Max. Fuse Size
-40°F to 10°F
181
450
200-230V 3~ 60HZ
180 - 253
26.37
45
Compressor MODEL
Compressor BOM
Compressor LRA
Compressor RLA
VSAG523ZXT
VS120RT-006-A4
156.1
17.88
OverLoad
Relay
Run Capacitor
Run Capacitor Rating
Start Capacitor
Start Capacitor Rating
Contactor
INTERNAL
Unit Drawing
Wiring no Fan controls
DGU1950-L302
WD23-2XT2L
91014B
OPTIONAL
Fan Motor
Fan Motor Qty
Fan Motor RLA
Fan Blade
Fan Guard
Shroud
810S186B40
2
1.9
51528-3
70832
70611-1
High Pressure switch
Low Pressure Control
Dual Pressure Conrol
84095-2L
84026-2
Condenser
Head Master Valve
Check Valve
Process Valve
Liquid Valve
Suction Valve
50777-6
70107-1
56627
Receiver
Receiver Qty
Accumulator
Liquid Filter
Sight Glass
Suction Filter
51084
1
TK00044000
52000-164D
70084-2
70822-5S
CrankCase Heater
14947870
Adjustable Fan Ctrl (A)
LAFC-001
Defrost Timer (Tn)
LTCG-T2
Receiver Heater (R)
LHR-223
Solenoid Valve (S)
KSVC-285
Disconnect (D)
KDSG-601
BOM INDEX DESCRIPTION
31529-2
32xYYYY- 2ERA(F)TnDS
E Enclosure
R Receiver Heater
A Adjustable fan control
F Fixed fan Control
T1 Defrost timer option
T2 Defrost timer & Defrost Heaters Contactor
D Disconnect
S Solenoid liquid Valve (supplied loose)
NOTES
IMPORTANT:
COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD
PROTECTOR. ALLOW TIME FOR RESET.
USE COPPER CONDUCTORS ONLY.
(EMPLOYER DES CONDUCTEUERS DE CUIVER
SEULEMENT.)
4
3
X
N
1
2
DEFROST CONTROL
RANCO
8145-xx
PRECISION 6145-xx
FAN 1
DEFROST
HEATERS
CONTACTOR COIL
FIELD WIRING NOTES
1.
ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL
APPLICABLE LOCAL AND NATIONAL CODES.
2. CONNECT INCOMING POWER LEADS FROM POWER SUPPLY
TO L1, L2, AND L3 IN COMPRESSOR CONTACTOR OR TO L1, L2 AND L3 IN
DISCONNECT SWITCH (IF PROVIDED). USE COOPER CONDUCTORS
ONLY. (EMPLOYER DES CONDUCTEURS DE CUIVER SEULEMENT.)
PROVIDE EQUIPMENT GROUNDING CONDUCTOR.
USE 75°C (MIN.) WIRING
3. DEFROST HEATERS LOADS SHOULD NOT BE HIGHER THEN THE
MAXIMUM HEATERS LOAD INDICATED ON THE UNIT LABEL.
DEFROST HEATERS TO BE CONTROLLED WITH A CONTACTOR AS SHOWN
ON THE DIAGRAM.
COMPRESSOR CONTACTOR
NC AUXILIARY SWITCH
FAN 2
GENERAL NOTES:
SOLENOID
LIQUID INJECTION
A. CONTACTOR COIL CIRCUIT IS FACTORY CONNECTED TO 230 V SOURCE IN
PANEL AS SHOWN
B. COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR.
ALLOW TIME FOR RESET.
COMPRESSOR CONTACTOR
NO AUXILIARY SWITCH
FC
COMPRESSOR
CONTACTOR COIL
see note A
HP
LP
FAN CONTROL
DT
LP
LOW PRESSURE CONTROL
TERMINAL
BOARD
P1
RECEIVER
HEATER
L2
L1
L3
T1
T3
F1
F2
HP
THERMOSTAT
HIGH PRESSURE SWITCH
POWER SUPPLY
208-230 / 60 / 3
L3
T3
L2
T2
L1
T1
DT
DISCHARGE LINE THERMOSTAT
FACTORY COMPONENTS
GRD
CRANK CASE
HEATER
COMPRESSOR
CONTACTOR
L1
L2
L3
T1
T2
T3
DEFROST
HEATERS
CONTACTOR
L1
L2
L3
T1
T2
T3
OPTIONAL FACTORY COMPONENTS
OPTIONAL FIELD COMPONENTS
BLACK
C
S
R
RED
YELLOW
CONDENSING UNIT WIRING, 230V 60Hz 3 Ph,
Liquid Injection Solenoid,
Fan control,
T1 & T2 defrost options
REL
REVISION
MAR. 11, 2011
COMPRESSOR
TERMINAL
L:\~ Andreea temp\ZZ Low Temp Scroll Datasheets\WORD_datasheets\Outdoor units\VSAG529ZXTHM_preliminary.doc
WD23-2XT2L
14/10/2011