Download Tecumseh VSAG529ZXTHM Performance Data Sheet
Transcript
VSAG529ZXTHM TPC___preliminary October 14, 2011 TECUMSEH HERMETIC CONDENSING UNIT Model BOM Air Cooled Application Refrigerant VSAG529ZXTHM 32L7242-2E 7 ¼ HP Low Temp R404A 47.75 46.97 31.58 29.00 26.00 4.50 SUCTION 7/8" LIQUID 1/2" Dim. Enclosure(inch)* VSAG529ZXTHM L W 29.40 47.75 *) Enclosure Mounting Holes, 26.25 x 58.5 Line connections H Suction Liquid 31.58 7/8 Sweat 1/2 Sweat Pumpdown o 90% @ 90 F 37.69 Air flow Oil Ch. Gross weight SCFM Oz. Lbs. 4200 24 600 Factory charge 20 psig dry air, MUST BE EVACUATED Evaporator T, °F -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 PSIG 5.5 8.0 10.7 14.0 17.1 19.3 24.5 28.8 33.5 36.5 43.7 BTUH 13400 15300 17400 19800 22400 25100 28000 31100 34200 37400 40700 85°F Watts Head 4760 218 4890 222 5040 226 5200 231 5370 236 5550 241 5750 247 5960 253 6190 259 6440 265 6710 272 o Cond T 94 96 97 99 100 102 103 105 107 108 110 BTUH 12700 14400 16200 18400 20700 23200 25900 28600 31500 34500 37600 Ambient Temperatures 95°F 100°F Watts Head Cond T BTUH Watts Head 5270 251 104 12400 5570 269 5390 255 105 13900 5690 273 5530 259 107 15700 5810 277 5670 263 108 17700 5950 281 5830 268 109 19900 6110 286 6010 273 110 22300 6280 291 6200 279 112 24900 6470 296 6410 285 113 27600 6680 302 6640 291 115 30400 6910 308 6900 297 117 33200 7160 315 36100 7430 322 7170 304 118 Cond T 109 110 111 112 114 115 116 118 119 121 122 BTUH 10900 12200 13800 15600 17700 19900 22200 24700 27300 30000 32700 110°F Watts Head 6240 307 6330 310 6440 313 6570 317 6710 321 6870 326 7050 331 7250 337 7470 343 7720 350 7990 357 Cond T 119 120 120 121 122 124 125 126 127 129 130 o Performance @ 60 Hz, Return gas 40 F, SubCooling 5 F PRELIMINARY PERFORMANCE DATA L:\~ Andreea temp\ZZ Low Temp Scroll Datasheets\WORD_datasheets\Outdoor units\VSAG529ZXTHM_preliminary.doc 14/10/2011 VSAG529ZXTHM TPC___preliminary October 14, 2011 Parts/Specifications STANDARD Unit BOM Unit MODEL 32L7242-2E VSAG529ZXTHM Refrigeration RANGE Design Pressure Low Design Pressure High Volts - HZ - Ph Voltage Range Min. Circuit Ampacity Max. Fuse Size -40°F to 10°F 181 450 200-230V 3~ 60HZ 180 - 253 26.37 45 Compressor MODEL Compressor BOM Compressor LRA Compressor RLA VSAG523ZXT VS120RT-006-A4 156.1 17.88 OverLoad Relay Run Capacitor Run Capacitor Rating Start Capacitor Start Capacitor Rating Contactor INTERNAL Unit Drawing Wiring no Fan controls DGU1950-L302 WD23-2XT2L 91014B OPTIONAL Fan Motor Fan Motor Qty Fan Motor RLA Fan Blade Fan Guard Shroud 810S186B40 2 1.9 51528-3 70832 70611-1 High Pressure switch Low Pressure Control Dual Pressure Conrol 84095-2L 84026-2 Condenser Head Master Valve Check Valve Process Valve Liquid Valve Suction Valve 50777-6 70107-1 56627 Receiver Receiver Qty Accumulator Liquid Filter Sight Glass Suction Filter 51084 1 TK00044000 52000-164D 70084-2 70822-5S CrankCase Heater 14947870 Adjustable Fan Ctrl (A) LAFC-001 Defrost Timer (Tn) LTCG-T2 Receiver Heater (R) LHR-223 Solenoid Valve (S) KSVC-285 Disconnect (D) KDSG-601 BOM INDEX DESCRIPTION 31529-2 32xYYYY- 2ERA(F)TnDS E Enclosure R Receiver Heater A Adjustable fan control F Fixed fan Control T1 Defrost timer option T2 Defrost timer & Defrost Heaters Contactor D Disconnect S Solenoid liquid Valve (supplied loose) NOTES IMPORTANT: COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR. ALLOW TIME FOR RESET. USE COPPER CONDUCTORS ONLY. (EMPLOYER DES CONDUCTEUERS DE CUIVER SEULEMENT.) 4 3 X N 1 2 DEFROST CONTROL RANCO 8145-xx PRECISION 6145-xx FAN 1 DEFROST HEATERS CONTACTOR COIL FIELD WIRING NOTES 1. ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL APPLICABLE LOCAL AND NATIONAL CODES. 2. CONNECT INCOMING POWER LEADS FROM POWER SUPPLY TO L1, L2, AND L3 IN COMPRESSOR CONTACTOR OR TO L1, L2 AND L3 IN DISCONNECT SWITCH (IF PROVIDED). USE COOPER CONDUCTORS ONLY. (EMPLOYER DES CONDUCTEURS DE CUIVER SEULEMENT.) PROVIDE EQUIPMENT GROUNDING CONDUCTOR. USE 75°C (MIN.) WIRING 3. DEFROST HEATERS LOADS SHOULD NOT BE HIGHER THEN THE MAXIMUM HEATERS LOAD INDICATED ON THE UNIT LABEL. DEFROST HEATERS TO BE CONTROLLED WITH A CONTACTOR AS SHOWN ON THE DIAGRAM. COMPRESSOR CONTACTOR NC AUXILIARY SWITCH FAN 2 GENERAL NOTES: SOLENOID LIQUID INJECTION A. CONTACTOR COIL CIRCUIT IS FACTORY CONNECTED TO 230 V SOURCE IN PANEL AS SHOWN B. COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR. ALLOW TIME FOR RESET. COMPRESSOR CONTACTOR NO AUXILIARY SWITCH FC COMPRESSOR CONTACTOR COIL see note A HP LP FAN CONTROL DT LP LOW PRESSURE CONTROL TERMINAL BOARD P1 RECEIVER HEATER L2 L1 L3 T1 T3 F1 F2 HP THERMOSTAT HIGH PRESSURE SWITCH POWER SUPPLY 208-230 / 60 / 3 L3 T3 L2 T2 L1 T1 DT DISCHARGE LINE THERMOSTAT FACTORY COMPONENTS GRD CRANK CASE HEATER COMPRESSOR CONTACTOR L1 L2 L3 T1 T2 T3 DEFROST HEATERS CONTACTOR L1 L2 L3 T1 T2 T3 OPTIONAL FACTORY COMPONENTS OPTIONAL FIELD COMPONENTS BLACK C S R RED YELLOW CONDENSING UNIT WIRING, 230V 60Hz 3 Ph, Liquid Injection Solenoid, Fan control, T1 & T2 defrost options REL REVISION MAR. 11, 2011 COMPRESSOR TERMINAL L:\~ Andreea temp\ZZ Low Temp Scroll Datasheets\WORD_datasheets\Outdoor units\VSAG529ZXTHM_preliminary.doc WD23-2XT2L 14/10/2011