VSAG522ZXTXM TPC___preliminary October 14, 2011 TECUMSEH HERMETIC CONDENSING UNIT Model BOM Air Cooled Application Refrigerant VSAG522ZXTXM 32T5442-2 5 ½ HP Low Temp R404A 45.01 28.50 26.78 17.50 1.50 SUCTION 7/8" LIQUID 1/2" 39.94 41.78 Dimensions (inch)* VSAG522ZXTXM L 28.50 *) Mounting Holes, 17.50 x 39.94 Line connections W H Suction Liquid 44.97 26.78 7/8 Sweat 1/2 Sweat Pumpdown Air flow Oil Ch. Gross weight 90% @ 90oF 37.69 SCFM Oz. Lbs. 4200 24 400 Factory charge 20 psig dry air, MUST BE EVACUATED Evaporator T, °F -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 PSIG 5.5 8.0 10.7 14.0 17.1 19.3 24.5 28.8 33.5 36.5 43.7 BTUH 8800 11000 13200 15400 17700 20200 22700 25400 28200 31200 34400 80°F Watts Head 3980 194 4050 197 4130 201 4230 206 4340 210 4460 215 4590 220 4730 225 4870 230 5020 236 5170 242 Cond T 87 88 89 91 92 94 95 97 98 100 102 BTUH 8400 10200 12100 14000 16000 18200 20400 22800 25400 28200 31100 Ambient Temperatures 90°F 100°F Watts Head Cond T BTUH Watts Head 4380 225 97 8600 4790 260 4460 229 98 10100 4870 263 4550 232 99 11700 4970 267 4650 236 100 13300 5080 271 4760 241 101 15100 5200 275 4890 245 103 16900 5330 279 5020 250 104 18900 5460 284 5160 255 105 21100 5610 289 5310 260 107 23500 5760 294 5460 266 109 26000 5910 300 5620 272 110 28800 6070 306 Cond T 107 108 109 110 111 112 113 114 116 117 119 BTUH 8300 9500 10800 12200 13600 15300 17000 19000 21100 23500 26100 110°F Watts Head 5190 299 5280 302 5380 305 5500 308 5630 312 5760 317 5900 321 6050 326 6210 331 6370 337 6530 343 Cond T 117 118 118 119 120 121 122 124 125 126 127 Performance @ 60 Hz, Return gas 40oF, SubCooling 5oF PRELIMINARY PERFORMANCE DATA L:\~ Andreea temp\ZZ Low Temp Scroll Datasheets\WORD_datasheets\Indoor units\VSAG522ZXTXM_preliminary.doc 14/10/2011 VSAG522ZXTXM TPC___preliminary October 14, 2011 Parts/Specifications Unit BOM Unit MODEL 32T5442-2 VSAG522ZXTXM Refrigeration RANGE Design Pressure Low Design Pressure High Volts - HZ - Ph Voltage Range Min. Circuit Ampacity Max. Fuse Size -40°F to 10°F 181 450 200-230V 3~ 60HZ 180 - 253 24.31 40 Compressor Compressor Compressor Compressor VSAG518ZXT VS119RT-006-A4 153 16.41 MODEL BOM LRA RLA OverLoad Relay Run Capacitor Run Capacitor Rating Start Capacitor Start Capacitor Rating Contactor INTERNAL Unit Drawing Wiring Diagram DGU1950-14 WD23-2FL 91014B Fan Motor Fan Motor Qty Fan Motor RLA Fan Blade Fan Guard Shroud 810S186B40 2 1.9 51528-3 70832 70611-1 High Pressure switch Low Pressure Control Dual Pressure Conrol 84095-2 84026-2 Condenser Head Master Valve Check Valve Process Valve Liquid Valve Suction Valve 50777-6 31529-2 Receiver Receiver Qty Accumulator Liquid Filter Sight Glass Suction Filter 51084 1 TK00044000 52000-164D 70084-2 70822-5S CrankCase Heater NOTES IMPORTANT: COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR. ALLOW TIME FOR RESET. USE COPPER CONDUCTORS ONLY. (EMPLOYER DES CONDUCTEUERS DE CUIVER SEULEMENT.) FIELD WIRING NOTES 1. ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL APPLICABLE LOCAL AND NATIONAL CODES. 2. CONNECT INCOMING POWER LEADS FROM POWER SUPPLY TO L1, L2, AND L3 IN COMPRESSOR CONTACTOR OR TO L1, L2 AND L3 IN DISCONNECT SW ITCH (IF PROVIDED). USE COOPER CONDUCTORS ONLY. (EMPLOYER DES CONDUCTEURS DE CUIVER SEULEMENT.) PROVIDE EQUIPMENT GROUNDING CONDUCTOR. USE 75°C (MIN.) WIRING 3. IF REQUIRED INSTALL SYSTEM REMOTE CONTROL BETW EEN P1 AND P2 IN TERMINAL BLOCK AND REMOVE THE JUMPER FAN 1 FAN 2 GENERAL NOTES: SOLENOID LIQUID INJECTION A. CONTACTOR COIL CIRCUIT IS FACTORY CONNECTED TO 230 V SOURCE IN PANEL AS SHOWN B. COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR. ALLOW TIME FOR RESET. COMPRESSOR CONTACTOR NO AUXILIARY SW ITCH FFC1 (FFC2) COMPRESSOR CONTACTOR COIL see note A HP DT FFC1 FFC2 LP LOW PRESSURE CONTROL TERMINAL BOARD P1 RECEIVER HEATER FAN CONTROL 1 (2) LP P3 P2 HP THERMOSTAT HIGH PRESSURE SWITCH POWER SUPPLY 208-230 / 60 / 3 L3 T3 L2 T2 L1 T1 DT DISCHARGE LINE THERMOSTAT FACTORY COMPONENTS GRD CRANK CASE HEATER COMPRESSOR CONTACTOR L1 L2 L3 T1 T2 T3 OPTIONAL FACTORY COMPONENTS OPTIONAL FIELD COMPONENTS COMPRESSOR TERMINAL BLACK S R RED YELLOW REL REVISION L:\~ Andreea temp\ZZ Low Temp Scroll Datasheets\WORD_datasheets\Indoor units\VSAG522ZXTXM_preliminary.doc DEC 21, 2010 C CONDENSING UNIT WIRING, 230V 60Hz 3 Ph, Liquid Injection Solenoid, Fan control, WD23-2FL 14/10/2011