VSAG522ZXTHM
TPC___preliminary
October 14, 2011
TECUMSEH HERMETIC
CONDENSING UNIT
Model
BOM
Air Cooled
Application
Refrigerant
VSAG522ZXTHM
32L5442-2E
5 ½ HP
Low Temp
R404A
47.75
46.97
31.58
29.00
26.00
4.50
SUCTION 7/8"
LIQUID 1/2"
Dim. Enclosure(inch)*
VSAG522ZXTHM
L
W
29.40 47.75
*) Enclosure Mounting Holes, 26.25 x 58.5
Line connections
Pumpdown
H
Suction
Liquid
31.58
7/8 Sweat
1/2 Sweat
o
90% @ 90 F
37.69
Air flow
Oil Ch.
Gross weight
SCFM
Oz.
Lbs.
4200
24
600
Factory charge 20 psig dry air, MUST BE EVACUATED
Ambient Temperatures
Evaporator
T, °F
-40
-35
-30
-25
-20
-15
-10
-5
0
5
10
PSIG
5.5
8.0
10.7
14.0
17.1
19.3
24.5
28.8
33.5
36.5
43.7
BTUH
8400
10400
12400
14500
16700
19000
21400
23900
26600
29500
32600
85°F
Watts
Head
4180
209
4250
212
4340
216
4440
220
4550
225
4670
229
4800
234
4940
239
5090
245
5240
250
5390
257
Cond T
92
93
94
95
97
98
99
101
103
104
106
BTUH
8500
10100
11900
13600
15500
17500
19700
21900
24400
27000
29900
95°F
Watts Head
4580
242
4660
246
4760
249
4860
253
4980
257
5110
262
5240
266
5380
271
5530
277
5690
283
5840
289
Cond T
102
103
104
105
106
107
109
110
111
113
114
BTUH
8600
10100
11700
13300
15100
16900
18900
21100
23500
26000
28800
100°F
Watts
Head
4790
260
4870
263
4970
267
5080
271
5200
275
5330
279
5460
284
5610
289
5760
294
5910
300
6070
306
Cond T
107
108
109
110
111
112
113
114
116
117
119
BTUH
8300
9500
10800
12200
13600
15300
17000
19000
21100
23500
26100
110°F
Watts
Head
5190
299
5280
302
5380
305
5500
308
5630
312
5760
317
5900
321
6050
326
6210
331
6370
337
6530
343
Cond T
117
118
118
119
120
121
122
124
125
126
127
Performance @ 60 Hz, Return gas 40oF, SubCooling 5oF
PRELIMINARY PERFORMANCE DATA
L:\~ Andreea temp\ZZ Low Temp Scroll Datasheets\WORD_datasheets\Outdoor units\VSAG522ZXTHM_preliminary.doc
14/10/2011
VSAG522ZXTHM
TPC___preliminary
October 14, 2011
Parts/Specifications
STANDARD
Unit BOM
Unit MODEL
32L5442-2E
VSAG522ZXTHM
Refrigeration RANGE
Design Pressure Low
Design Pressure High
Volts - HZ - Ph
Voltage Range
Min. Circuit Ampacity
Max. Fuse Size
-40°F to 10°F
181
450
200-230V 3~ 60HZ
180 - 253
24.52
40
Compressor MODEL
Compressor BOM
Compressor LRA
Compressor RLA
VSAG518ZXT
VS119RT-006-A4
153
16.41
OverLoad
Relay
Run Capacitor
Run Capacitor Rating
Start Capacitor
Start Capacitor Rating
Contactor
INTERNAL
Unit Drawing
Wiring no Fan controls
DGU1950-L302
WD23-2XT2L
91014B
OPTIONAL
Fan Motor
Fan Motor Qty
Fan Motor RLA
Fan Blade
Fan Guard
Shroud
810S186B40
2
1.9
51528-3
70832
70611-1
Adjustable Fan Ctrl (A)
LAFC-001
Defrost Timer (Tn)
LTCG-T2
Receiver Heater (R)
LHR-223
High Pressure switch
Low Pressure Control
Dual Pressure Conrol
84095-2L
84026-2
Solenoid Valve (S)
KSVC-285
Disconnect (D)
KDSG-601
Condenser
Head Master Valve
Check Valve
Process Valve
Liquid Valve
Suction Valve
50777-6
70107-1
56627
Receiver
Receiver Qty
Accumulator
Liquid Filter
Sight Glass
Suction Filter
51084
1
TK00044000
52000-164D
70084-2
70822-5S
CrankCase Heater
14947870
BOM INDEX DESCRIPTION
32xYYYY- 2ERA(F)TnDS
E Enclosure
R Receiver Heater
A Adjustable fan control
F Fixed fan Control
T1 Defrost timer option
T2 Defrost timer & Defrost Heaters Contactor
D Disconnect
S Solenoid liquid Valve (supplied loose)
31529-2
NOTES
IMPORTANT:
COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD
PROTECTOR. ALLOW TIME FOR RESET.
USE COPPER CONDUCTORS ONLY.
(EMPLOYER DES CONDUCTEUERS DE CUIVER
SEULEMENT.)
4
3
X
N
1
2
DEFROST CONTROL
RANCO
8145-xx
PRECISION 6145-xx
FAN 1
DEFROST
HEATERS
CONTACTOR COIL
FIELD WIRING NOTES
1.
ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL
APPLICABLE LOCAL AND NATIONAL CODES.
2. CONNECT INCOMING POWER LEADS FROM POWER SUPPLY
TO L1, L2, AND L3 IN COMPRESSOR CONTACTOR OR TO L1, L2 AND L3 IN
DISCONNECT SWITCH (IF PROVIDED). USE COOPER CONDUCTORS
ONLY. (EMPLOYER DES CONDUCTEURS DE CUIVER SEULEMENT.)
PROVIDE EQUIPMENT GROUNDING CONDUCTOR.
USE 75°C (MIN.) WIRING
3. DEFROST HEATERS LOADS SHOULD NOT BE HIGHER THEN THE
MAXIMUM HEATERS LOAD INDICATED ON THE UNIT LABEL.
DEFROST HEATERS TO BE CONTROLLED WITH A CONTACTOR AS SHOWN
ON THE DIAGRAM.
COMPRESSOR CONTACTOR
NC AUXILIARY SWITCH
FAN 2
GENERAL NOTES:
SOLENOID
LIQUID INJECTION
A. CONTACTOR COIL CIRCUIT IS FACTORY CONNECTED TO 230 V SOURCE IN
PANEL AS SHOWN
B. COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR.
ALLOW TIME FOR RESET.
COMPRESSOR CONTACTOR
NO AUXILIARY SWITCH
FC
COMPRESSOR
CONTACTOR COIL
see note A
HP
LP
FAN CONTROL
DT
LP
LOW PRESSURE CONTROL
TERMINAL
BOARD
P1
RECEIVER
HEATER
L2
L1
L3
T1
T3
F1
F2
HP
THERMOSTAT
HIGH PRESSURE SWITCH
POWER SUPPLY
208-230 / 60 / 3
L3
T3
L2
T2
L1
T1
DT
DISCHARGE LINE THERMOSTAT
FACTORY COMPONENTS
GRD
CRANK CASE
HEATER
COMPRESSOR
CONTACTOR
L1
L2
L3
T1
T2
T3
DEFROST
HEATERS
CONTACTOR
L1
L2
L3
T1
T2
T3
OPTIONAL FACTORY COMPONENTS
OPTIONAL FIELD COMPONENTS
BLACK
C
S
R
RED
YELLOW
CONDENSING UNIT WIRING, 230V 60Hz 3 Ph,
Liquid Injection Solenoid,
Fan control,
T1 & T2 defrost options
REL
REVISION
MAR. 11, 2011
COMPRESSOR
TERMINAL
WD23-2XT2L
L:\~ Andreea temp\ZZ Low Temp Scroll Datasheets\WORD_datasheets\Outdoor units\VSAG522ZXTHM_preliminary.doc
14/10/2011