Download Tecumseh AWA9517ZXTHN Performance Data Sheet
Transcript
AWA9517ZXTHN TPC___REV 1 March 21, 2012 TECUMSEH HERMETIC CONDENSING UNIT Model BOM Air Cooled Application Refrigerant AWA9517ZXTHN 32L2142-2E 2 HP Commercial Temp R404A 36.25 35.38 26.08 25.50 23.50 4.24 1.11 SUCTION 5/8" SWEAT LIQUID 3/8" SWEAT Dim. Enclosure(inch)* L W H Model Line connections Suction Liquid AWA9517ZXTHN 31.50 40.50 26.75 *) Enclosure Mounting Holes, 38.5 x 25.5 Factory charge 20 psig dry air, MUST BE EVACUATED Evaporator o F -10 -5 0 5 10 15 20 25 30 35 40 45 50 55 Psig 23.2 27.5 32.1 37.0 42.4 48.2 54.5 61.2 68.4 76.1 84.4 93.2 103.0 113.0 5/8 o BTUH 8300 9600 11000 12600 14200 16000 17900 19900 22000 24300 26700 29200 31800 34500 80 F Watts Head Cond T 1900 198 86 2010 201 87 2120 204 88 2230 209 89 2350 213 90 2470 218 91 2590 224 93 2720 231 94 2860 238 96 2990 246 98 3130 255 100 3280 264 102 3430 274 104 3580 284 106 o BTUH 6900 8000 9100 10400 11900 13400 15100 16900 18800 20800 23000 25300 27700 30200 3/8 Pumpdown o 90% @ 90 F Air flow SCFM Oil Ch. Oz. Gross weight Lbs. 20.45 1800 38.6 320 Ambient Temeratures o o 95 F 100 F Watts Head Cond T BTUH Watts Head Cond T 1930 244 101 6400 1930 260 106 2050 247 102 7400 2060 263 106 2180 250 102 8500 2190 267 107 2310 254 103 9700 2330 271 108 2440 259 104 11100 2470 276 109 2580 264 106 12500 2610 281 110 2720 270 107 14100 2760 287 111 2860 277 108 15800 2910 294 113 3010 284 110 17700 3060 301 114 3160 292 111 19600 3220 309 116 3320 301 113 21700 3380 317 117 3480 310 115 23900 3540 327 119 3640 320 116 26300 3710 336 121 3810 330 118 28700 3880 347 122 o o o o BTUH 5400 6200 7100 8200 9400 10700 12200 13700 15400 17200 19200 21200 23400 25700 110 F Watts Head Cond T 1930 297 115 2070 300 116 2220 303 117 2370 307 118 2520 312 119 2680 318 120 2840 324 121 3000 330 122 3170 337 123 3340 345 125 3510 354 126 3690 363 128 3870 372 129 4050 382 131 o Performance @ 60 Hz ; Return Gas Temperature 20 F max superheat above 20 F evap, 40 F max below 20 F evap ; --- SubCooling 5 F PRELIMINARY PERFORMANCE DATA L:\~ Andreea temp\ZZ Follett Datasheets\TecDataSheet Info\WORD_datasheets\AWA9517ZXTHN_REV1.doc 21/03/2012 AWA9517ZXTHN TPC___REV 1 March 21, 2012 Parts/Specifications STANDARD Unit BOM Unit MODEL 32L2142-2E AWA9517ZXTHN Refrigeration RANGE Design Pressure Low Design Pressure High Volts - HZ - Ph Voltage Range Min. Circuit Ampacity Max. Fuse Size -10°F to 45°F 181 450 200-230V 3~ 60HZ 180 - 254 14.03 25 Compressor MODEL Compressor BOM Compressor LRA Compressor RLA AW617RT-120-A2 AWA9514ZXT 63.4 7.30 OverLoad Relay Run Capacitor Run Capacitor Rating Start Capacitor Start Capacitor Rating Contactor 91014B Unit Drawing Wiring Diagram DGU1918-L104 WD23-2FM OPTIONAL Fan Motor Fan Motor Qty Fan Motor RLA Fan Blade Fan Guard Shroud 810F050C20 2 0.7 51568 70831 70648-2 High Pressure switch Low Pressure Control Dual Pressure Conrol 84095-2L 84026-2 Condenser Head Master Valve Check Valve Process Valve Liquid Valve Suction Valve 50858-1 70083-1 56626 31583-1 56500-K06 56500-K10 Receiver Receiver Qty Accumulator Liquid Filter Sight Glass Suction Filter 51099-2L 1 70081-3 70084 70822-6S CrankCase Heater 91022-1 Fix.Fan Switch #1 (F opt.) Fix.Fan Switch #2 (F opt.) Adjus. Fan Ctrl. (A opt.) Defrost Clock (Tn option) Defrost Heaters Contactor Rec. Heater (R option) Solenoid Valve (loose) Disconnect (D option) 84132-01 Wiring with F option Wiring with A option WD23-2AT2 Phase monitor, ICM402 900-10026 BOM INDEX DESCRIPTION 32xYYYY- 2ERA(F)TnDS E Enclosure R Receiver Heater A Adjustable fan control F Fixed fan Control T1 Defrost timer option T2 Defrost timer & Defrost Heaters Contactor D Disconnect S Solenoid liquid Valve (supplied loose) NOTES IMPORTANT: COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR. ALLOW TIME FOR RESET. USE COPPER CONDUCTORS ONLY. (EMPLOYER DES CONDUCTEUERS DE CUIVER SEULEMENT.) FIELD WIRING NOTES 1. ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL APPLICABLE LOCAL AND NATIONAL CODES. 2. CONNECT INCOMING POWER LEADS FROM POWER SUPPLY TO L1, L2, AND L3 IN COMPRESSOR CONTACTOR OR TO L1, L2 AND L3 IN DISCONNECT SWITCH (IF PROVIDED). USE COOPER CONDUCTORS ONLY. (EMPLOYER DES CONDUCTEURS DE CUIVER SEULEMENT.) PROVIDE EQUIPMENT GROUNDING CONDUCTOR. USE 75°C (MIN.) WIRING FAN 1 FAN 2 GENERAL NOTES: A. CONTACTOR COIL CIRCUIT IS FACTORY CONNECTED TO 230 V SOURCE IN TO "Y-OUT" AT PHASE MONITOR COMPRESSOR CONTACTOR COIL see note A HP LP A B D.T. C TERMINAL BOARD P1 PANEL AS SHOWN B. COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR. ALLOW TIME FOR RESET. TO "230 VAC" AT PHASE MONITOR L1 FFC TO "C" AT PHASE MONITOR L2 AFC L3 T1 T3 F1 F2 LP POWER SUPPLY 230-60-3 LOW PRESSURE CONTROL HP L3 T3 L2 T2 L1 T1 TO "P1" AT TERMINAL BOARD ADJUSTABLE FAN CONTROL HIGH PRESSURE SWITCH TO "L2" AT TERMINAL C BOARD A D.T. B TO "L1" AT TERMINAL BOARD DISCHARGE THERMOSTAT GRD FACTORY COMPONENTS CRANK CASE HEATER L1 L2 L3 T1 T2 T3 Y C 115 230 VAC VAC OPTIONAL FACTORY COMPONENTS ICM402 3 PHASE MONITOR COMPRESSOR TERMINAL L1 L2 L3 BLACK R CONDENSING UNIT WIRING, 230V 60Hz 3 Ph, fixed fan control, PHASE MONITOR OPTION RED YELLOW REVISION L:\~ Andreea temp\ZZ Follett Datasheets\TecDataSheet Info\WORD_datasheets\AWA9517ZXTHN_REV1.doc AUG. 18, 2009 C S YOUT WD23-2FM 21/03/2012