Download Tecumseh AWA9517ZXTHN Performance Data Sheet

Transcript
AWA9517ZXTHN
TPC___REV 1
March 21, 2012
TECUMSEH HERMETIC
CONDENSING UNIT
Model
BOM
Air Cooled
Application
Refrigerant
AWA9517ZXTHN
32L2142-2E
2 HP
Commercial Temp
R404A
36.25
35.38
26.08
25.50
23.50
4.24
1.11
SUCTION
5/8" SWEAT
LIQUID
3/8" SWEAT
Dim. Enclosure(inch)*
L
W
H
Model
Line connections
Suction
Liquid
AWA9517ZXTHN
31.50 40.50 26.75
*) Enclosure Mounting Holes, 38.5 x 25.5
Factory charge 20 psig dry air, MUST BE EVACUATED
Evaporator
o
F
-10
-5
0
5
10
15
20
25
30
35
40
45
50
55
Psig
23.2
27.5
32.1
37.0
42.4
48.2
54.5
61.2
68.4
76.1
84.4
93.2
103.0
113.0
5/8
o
BTUH
8300
9600
11000
12600
14200
16000
17900
19900
22000
24300
26700
29200
31800
34500
80 F
Watts Head Cond T
1900
198
86
2010
201
87
2120
204
88
2230
209
89
2350
213
90
2470
218
91
2590
224
93
2720
231
94
2860
238
96
2990
246
98
3130
255
100
3280
264
102
3430
274
104
3580
284
106
o
BTUH
6900
8000
9100
10400
11900
13400
15100
16900
18800
20800
23000
25300
27700
30200
3/8
Pumpdown
o
90% @ 90 F
Air flow
SCFM
Oil Ch.
Oz.
Gross weight
Lbs.
20.45
1800
38.6
320
Ambient Temeratures
o
o
95 F
100 F
Watts Head Cond T BTUH Watts Head Cond T
1930
244
101
6400 1930
260
106
2050
247
102
7400 2060
263
106
2180
250
102
8500 2190
267
107
2310
254
103
9700 2330
271
108
2440
259
104 11100 2470
276
109
2580
264
106 12500 2610
281
110
2720
270
107 14100 2760
287
111
2860
277
108 15800 2910
294
113
3010
284
110 17700 3060
301
114
3160
292
111 19600 3220
309
116
3320
301
113 21700 3380
317
117
3480
310
115 23900 3540
327
119
3640
320
116 26300 3710
336
121
3810
330
118 28700 3880
347
122
o
o
o
o
BTUH
5400
6200
7100
8200
9400
10700
12200
13700
15400
17200
19200
21200
23400
25700
110 F
Watts Head Cond T
1930
297
115
2070
300
116
2220
303
117
2370
307
118
2520
312
119
2680
318
120
2840
324
121
3000
330
122
3170
337
123
3340
345
125
3510
354
126
3690
363
128
3870
372
129
4050
382
131
o
Performance @ 60 Hz ; Return Gas Temperature 20 F max superheat above 20 F evap, 40 F max below 20 F evap ; --- SubCooling 5 F
PRELIMINARY PERFORMANCE DATA
L:\~ Andreea temp\ZZ Follett Datasheets\TecDataSheet Info\WORD_datasheets\AWA9517ZXTHN_REV1.doc
21/03/2012
AWA9517ZXTHN
TPC___REV 1
March 21, 2012
Parts/Specifications
STANDARD
Unit BOM
Unit MODEL
32L2142-2E
AWA9517ZXTHN
Refrigeration RANGE
Design Pressure Low
Design Pressure High
Volts - HZ - Ph
Voltage Range
Min. Circuit Ampacity
Max. Fuse Size
-10°F to 45°F
181
450
200-230V 3~ 60HZ
180 - 254
14.03
25
Compressor MODEL
Compressor BOM
Compressor LRA
Compressor RLA
AW617RT-120-A2
AWA9514ZXT
63.4
7.30
OverLoad
Relay
Run Capacitor
Run Capacitor Rating
Start Capacitor
Start Capacitor Rating
Contactor
91014B
Unit Drawing
Wiring Diagram
DGU1918-L104
WD23-2FM
OPTIONAL
Fan Motor
Fan Motor Qty
Fan Motor RLA
Fan Blade
Fan Guard
Shroud
810F050C20
2
0.7
51568
70831
70648-2
High Pressure switch
Low Pressure Control
Dual Pressure Conrol
84095-2L
84026-2
Condenser
Head Master Valve
Check Valve
Process Valve
Liquid Valve
Suction Valve
50858-1
70083-1
56626
31583-1
56500-K06
56500-K10
Receiver
Receiver Qty
Accumulator
Liquid Filter
Sight Glass
Suction Filter
51099-2L
1
70081-3
70084
70822-6S
CrankCase Heater
91022-1
Fix.Fan Switch #1 (F opt.)
Fix.Fan Switch #2 (F opt.)
Adjus. Fan Ctrl. (A opt.)
Defrost Clock (Tn option)
Defrost Heaters Contactor
Rec. Heater (R option)
Solenoid Valve (loose)
Disconnect (D option)
84132-01
Wiring with F option
Wiring with A option
WD23-2AT2
Phase monitor, ICM402
900-10026
BOM INDEX DESCRIPTION
32xYYYY- 2ERA(F)TnDS
E Enclosure
R Receiver Heater
A Adjustable fan control
F Fixed fan Control
T1 Defrost timer option
T2 Defrost timer & Defrost Heaters Contactor
D Disconnect
S Solenoid liquid Valve (supplied loose)
NOTES
IMPORTANT:
COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD
PROTECTOR. ALLOW TIME FOR RESET.
USE COPPER CONDUCTORS ONLY.
(EMPLOYER DES CONDUCTEUERS DE CUIVER
SEULEMENT.)
FIELD WIRING NOTES
1.
ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL
APPLICABLE LOCAL AND NATIONAL CODES.
2. CONNECT INCOMING POWER LEADS FROM POWER SUPPLY
TO L1, L2, AND L3 IN COMPRESSOR CONTACTOR OR TO L1, L2 AND L3 IN
DISCONNECT SWITCH (IF PROVIDED). USE COOPER CONDUCTORS
ONLY. (EMPLOYER DES CONDUCTEURS DE CUIVER SEULEMENT.)
PROVIDE EQUIPMENT GROUNDING CONDUCTOR.
USE 75°C (MIN.) WIRING
FAN 1
FAN 2
GENERAL NOTES:
A. CONTACTOR COIL CIRCUIT IS FACTORY CONNECTED TO 230 V SOURCE IN
TO "Y-OUT"
AT PHASE
MONITOR
COMPRESSOR
CONTACTOR COIL
see note A
HP
LP
A
B
D.T.
C
TERMINAL
BOARD
P1
PANEL AS SHOWN
B. COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR.
ALLOW TIME FOR RESET.
TO "230 VAC"
AT PHASE
MONITOR
L1
FFC
TO "C"
AT PHASE
MONITOR
L2
AFC
L3
T1
T3
F1
F2
LP
POWER SUPPLY
230-60-3
LOW PRESSURE CONTROL
HP
L3
T3
L2
T2
L1
T1
TO "P1"
AT TERMINAL
BOARD
ADJUSTABLE FAN CONTROL
HIGH PRESSURE SWITCH
TO "L2"
AT TERMINAL
C BOARD
A
D.T.
B
TO "L1"
AT TERMINAL
BOARD
DISCHARGE THERMOSTAT
GRD
FACTORY COMPONENTS
CRANK CASE
HEATER
L1
L2
L3
T1
T2
T3
Y
C
115 230
VAC VAC
OPTIONAL FACTORY COMPONENTS
ICM402
3 PHASE
MONITOR
COMPRESSOR
TERMINAL
L1 L2 L3
BLACK
R
CONDENSING UNIT WIRING, 230V 60Hz 3 Ph,
fixed fan control,
PHASE MONITOR OPTION
RED
YELLOW
REVISION
L:\~ Andreea temp\ZZ Follett Datasheets\TecDataSheet Info\WORD_datasheets\AWA9517ZXTHN_REV1.doc
AUG. 18, 2009
C
S
YOUT
WD23-2FM
21/03/2012