Download Tecumseh VSAG517ZXTHM Performance Data Sheet
Transcript
VSAG517ZXTHM TPC___preliminary October 14, 2011 TECUMSEH HERMETIC CONDENSING UNIT Model BOM Air Cooled Application Refrigerant VSAG517ZXTHM 32L4242-2E 4 ¼ HP Low Temp R404A 47.75 46.97 31.58 29.00 26.00 4.50 SUCTION 7/8" LIQUID 1/2" Dim. Enclosure(inch)* VSAG517ZXTHM L W 29.40 47.75 *) Enclosure Mounting Holes, 26.25 x 58.5 Line connections H Suction Liquid 31.58 7/8 Sweat 1/2 Sweat Pumpdown Air flow Oil Ch. Gross weight 90% @ 90oF 33.44 SCFM Oz. Lbs. 4200 24 550 Factory charge 20 psig dry air, MUST BE EVACUATED Evaporator T, °F -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 PSIG 5.5 8.0 10.7 14.0 17.1 19.3 24.5 28.8 33.5 36.5 43.7 BTUH 7800 9100 10500 12000 13500 15200 16900 18700 20600 22600 24600 85°F Watts Head 3710 217 3760 221 3830 225 3920 229 4030 234 4160 239 4300 244 4450 250 4610 256 4780 262 4940 269 Cond T 94 95 97 98 99 101 102 104 106 107 109 BTUH 7300 8500 9700 11100 12500 14000 15600 17300 19000 20900 22800 Ambient Temperatures 95°F 100°F Watts Head Cond T BTUH Watts Head 4060 252 105 7200 4240 271 4100 256 106 8300 4280 274 4170 259 107 9400 4340 278 4260 263 108 10700 4430 282 4360 268 109 12100 4530 286 4480 272 110 13500 4640 290 4620 277 111 15100 4770 295 4760 283 113 16700 4910 300 4910 288 114 18400 5060 305 5070 294 116 20200 5210 311 5220 301 117 22100 5360 318 Cond T 110 111 112 113 114 115 116 117 119 120 122 BTUH 6400 7300 8400 9500 10800 12100 13600 15100 16800 18500 20300 110°F Watts Head 4610 312 4640 315 4690 318 4770 321 4860 325 4970 329 5090 333 5220 337 5360 342 5500 348 5650 353 Cond T 120 121 122 122 123 124 125 126 127 128 130 Performance @ 60 Hz, Return gas 40oF, SubCooling 5oF PRELIMINARY PERFORMANCE DATA L:\~ Andreea temp\ZZ Low Temp Scroll Datasheets\WORD_datasheets\Outdoor units\VSAG517ZXTHM_preliminary.doc 14/10/2011 VSAG517ZXTHM TPC___preliminary October 14, 2011 Parts/Specifications STANDARD Unit BOM Unit MODEL 32L4242-2E VSAG517ZXTHM Refrigeration RANGE Design Pressure Low Design Pressure High Volts - HZ - Ph Voltage Range Min. Circuit Ampacity Max. Fuse Size -40°F to 10°F 181 450 200-230V 3~ 60HZ 180 - 253 19.77 30 Compressor MODEL Compressor BOM Compressor LRA Compressor RLA VSAG514ZXT VS118RT-006-A4 96 12.61 OverLoad Relay Run Capacitor Run Capacitor Rating Start Capacitor Start Capacitor Rating Contactor INTERNAL 91014B Unit Drawing Wiring no Fan controls DGU1950-L302 WD23-2XT2L OPTIONAL Fan Motor Fan Motor Qty Fan Motor RLA Fan Blade Fan Guard Shroud 810S186B40 2 1.9 51528-3 70832 70611-1 High Pressure switch Low Pressure Control Dual Pressure Conrol 84095-2L 84026-2 Condenser Head Master Valve Check Valve Process Valve Liquid Valve Suction Valve 50785-4 70107-1 56627 Receiver Receiver Qty Accumulator Liquid Filter Sight Glass Suction Filter 51084 1 TK00044000 52000-164D 70084-2 70822-5S CrankCase Heater 14947870 Adjustable Fan Ctrl (A) LAFC-001 Defrost Timer (Tn) LTCG-T2 Receiver Heater (R) LHR-223 Solenoid Valve (S) KSVC-285 Disconnect (D) KDSG-601 BOM INDEX DESCRIPTION 32xYYYY- 2ERA(F)TnDS E Enclosure R Receiver Heater A Adjustable fan control F Fixed fan Control T1 Defrost timer option T2 Defrost timer & Defrost Heaters Contactor D Disconnect S Solenoid liquid Valve (supplied loose) 31529-2 NOTES IMPORTANT: COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR. ALLOW TIME FOR RESET. USE COPPER CONDUCTORS ONLY. (EMPLOYER DES CONDUCTEUERS DE CUIVER SEULEMENT.) 4 3 X N 1 2 DEFROST CONTROL RANCO 8145-xx PRECISION 6145-xx FAN 1 DEFROST HEATERS CONTACTOR COIL FIELD WIRING NOTES 1. ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL APPLICABLE LOCAL AND NATIONAL CODES. 2. CONNECT INCOMING POWER LEADS FROM POWER SUPPLY TO L1, L2, AND L3 IN COMPRESSOR CONTACTOR OR TO L1, L2 AND L3 IN DISCONNECT SWITCH (IF PROVIDED). USE COOPER CONDUCTORS ONLY. (EMPLOYER DES CONDUCTEURS DE CUIVER SEULEMENT.) PROVIDE EQUIPMENT GROUNDING CONDUCTOR. USE 75°C (MIN.) WIRING 3. DEFROST HEATERS LOADS SHOULD NOT BE HIGHER THEN THE MAXIMUM HEATERS LOAD INDICATED ON THE UNIT LABEL. DEFROST HEATERS TO BE CONTROLLED WITH A CONTACTOR AS SHOWN ON THE DIAGRAM. COMPRESSOR CONTACTOR NC AUXILIARY SWITCH FAN 2 GENERAL NOTES: SOLENOID LIQUID INJECTION A. CONTACTOR COIL CIRCUIT IS FACTORY CONNECTED TO 230 V SOURCE IN PANEL AS SHOWN B. COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR. ALLOW TIME FOR RESET. COMPRESSOR CONTACTOR NO AUXILIARY SWITCH FC COMPRESSOR CONTACTOR COIL see note A HP LP FAN CONTROL DT LP LOW PRESSURE CONTROL TERMINAL BOARD P1 RECEIVER HEATER L2 L1 L3 T1 T3 F1 F2 HP THERMOSTAT HIGH PRESSURE SWITCH POWER SUPPLY 208-230 / 60 / 3 L3 T3 L2 T2 L1 T1 DT DISCHARGE LINE THERMOSTAT FACTORY COMPONENTS GRD CRANK CASE HEATER COMPRESSOR CONTACTOR L1 L2 L3 T1 T2 T3 DEFROST HEATERS CONTACTOR L1 L2 L3 T1 T2 T3 OPTIONAL FACTORY COMPONENTS OPTIONAL FIELD COMPONENTS BLACK C S R RED YELLOW CONDENSING UNIT WIRING, 230V 60Hz 3 Ph, Liquid Injection Solenoid, Fan control, T1 & T2 defrost options REL REVISION MAR. 11, 2011 COMPRESSOR TERMINAL WD23-2XT2L L:\~ Andreea temp\ZZ Low Temp Scroll Datasheets\WORD_datasheets\Outdoor units\VSAG517ZXTHM_preliminary.doc 14/10/2011