Download Tecumseh VSAG517ZXTHM Performance Data Sheet

Transcript
VSAG517ZXTHM
TPC___preliminary
October 14, 2011
TECUMSEH HERMETIC
CONDENSING UNIT
Model
BOM
Air Cooled
Application
Refrigerant
VSAG517ZXTHM
32L4242-2E
4 ¼ HP
Low Temp
R404A
47.75
46.97
31.58
29.00
26.00
4.50
SUCTION 7/8"
LIQUID 1/2"
Dim. Enclosure(inch)*
VSAG517ZXTHM
L
W
29.40 47.75
*) Enclosure Mounting Holes, 26.25 x 58.5
Line connections
H
Suction
Liquid
31.58
7/8 Sweat
1/2 Sweat
Pumpdown
Air flow
Oil Ch.
Gross weight
90% @ 90oF
33.44
SCFM
Oz.
Lbs.
4200
24
550
Factory charge 20 psig dry air, MUST BE EVACUATED
Evaporator
T, °F
-40
-35
-30
-25
-20
-15
-10
-5
0
5
10
PSIG
5.5
8.0
10.7
14.0
17.1
19.3
24.5
28.8
33.5
36.5
43.7
BTUH
7800
9100
10500
12000
13500
15200
16900
18700
20600
22600
24600
85°F
Watts Head
3710
217
3760
221
3830
225
3920
229
4030
234
4160
239
4300
244
4450
250
4610
256
4780
262
4940
269
Cond T
94
95
97
98
99
101
102
104
106
107
109
BTUH
7300
8500
9700
11100
12500
14000
15600
17300
19000
20900
22800
Ambient Temperatures
95°F
100°F
Watts Head Cond T BTUH Watts Head
4060
252
105
7200
4240
271
4100
256
106
8300
4280
274
4170
259
107
9400
4340
278
4260
263
108
10700 4430
282
4360
268
109
12100 4530
286
4480
272
110
13500 4640
290
4620
277
111
15100 4770
295
4760
283
113
16700 4910
300
4910
288
114
18400 5060
305
5070
294
116
20200 5210
311
5220
301
117
22100 5360
318
Cond T
110
111
112
113
114
115
116
117
119
120
122
BTUH
6400
7300
8400
9500
10800
12100
13600
15100
16800
18500
20300
110°F
Watts Head
4610
312
4640
315
4690
318
4770
321
4860
325
4970
329
5090
333
5220
337
5360
342
5500
348
5650
353
Cond T
120
121
122
122
123
124
125
126
127
128
130
Performance @ 60 Hz, Return gas 40oF, SubCooling 5oF
PRELIMINARY PERFORMANCE DATA
L:\~ Andreea temp\ZZ Low Temp Scroll Datasheets\WORD_datasheets\Outdoor units\VSAG517ZXTHM_preliminary.doc
14/10/2011
VSAG517ZXTHM
TPC___preliminary
October 14, 2011
Parts/Specifications
STANDARD
Unit BOM
Unit MODEL
32L4242-2E
VSAG517ZXTHM
Refrigeration RANGE
Design Pressure Low
Design Pressure High
Volts - HZ - Ph
Voltage Range
Min. Circuit Ampacity
Max. Fuse Size
-40°F to 10°F
181
450
200-230V 3~ 60HZ
180 - 253
19.77
30
Compressor MODEL
Compressor BOM
Compressor LRA
Compressor RLA
VSAG514ZXT
VS118RT-006-A4
96
12.61
OverLoad
Relay
Run Capacitor
Run Capacitor Rating
Start Capacitor
Start Capacitor Rating
Contactor
INTERNAL
91014B
Unit Drawing
Wiring no Fan controls
DGU1950-L302
WD23-2XT2L
OPTIONAL
Fan Motor
Fan Motor Qty
Fan Motor RLA
Fan Blade
Fan Guard
Shroud
810S186B40
2
1.9
51528-3
70832
70611-1
High Pressure switch
Low Pressure Control
Dual Pressure Conrol
84095-2L
84026-2
Condenser
Head Master Valve
Check Valve
Process Valve
Liquid Valve
Suction Valve
50785-4
70107-1
56627
Receiver
Receiver Qty
Accumulator
Liquid Filter
Sight Glass
Suction Filter
51084
1
TK00044000
52000-164D
70084-2
70822-5S
CrankCase Heater
14947870
Adjustable Fan Ctrl (A)
LAFC-001
Defrost Timer (Tn)
LTCG-T2
Receiver Heater (R)
LHR-223
Solenoid Valve (S)
KSVC-285
Disconnect (D)
KDSG-601
BOM INDEX DESCRIPTION
32xYYYY- 2ERA(F)TnDS
E Enclosure
R Receiver Heater
A Adjustable fan control
F Fixed fan Control
T1 Defrost timer option
T2 Defrost timer & Defrost Heaters Contactor
D Disconnect
S Solenoid liquid Valve (supplied loose)
31529-2
NOTES
IMPORTANT:
COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD
PROTECTOR. ALLOW TIME FOR RESET.
USE COPPER CONDUCTORS ONLY.
(EMPLOYER DES CONDUCTEUERS DE CUIVER
SEULEMENT.)
4
3
X
N
1
2
DEFROST CONTROL
RANCO
8145-xx
PRECISION 6145-xx
FAN 1
DEFROST
HEATERS
CONTACTOR COIL
FIELD WIRING NOTES
1.
ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL
APPLICABLE LOCAL AND NATIONAL CODES.
2. CONNECT INCOMING POWER LEADS FROM POWER SUPPLY
TO L1, L2, AND L3 IN COMPRESSOR CONTACTOR OR TO L1, L2 AND L3 IN
DISCONNECT SWITCH (IF PROVIDED). USE COOPER CONDUCTORS
ONLY. (EMPLOYER DES CONDUCTEURS DE CUIVER SEULEMENT.)
PROVIDE EQUIPMENT GROUNDING CONDUCTOR.
USE 75°C (MIN.) WIRING
3. DEFROST HEATERS LOADS SHOULD NOT BE HIGHER THEN THE
MAXIMUM HEATERS LOAD INDICATED ON THE UNIT LABEL.
DEFROST HEATERS TO BE CONTROLLED WITH A CONTACTOR AS SHOWN
ON THE DIAGRAM.
COMPRESSOR CONTACTOR
NC AUXILIARY SWITCH
FAN 2
GENERAL NOTES:
SOLENOID
LIQUID INJECTION
A. CONTACTOR COIL CIRCUIT IS FACTORY CONNECTED TO 230 V SOURCE IN
PANEL AS SHOWN
B. COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR.
ALLOW TIME FOR RESET.
COMPRESSOR CONTACTOR
NO AUXILIARY SWITCH
FC
COMPRESSOR
CONTACTOR COIL
see note A
HP
LP
FAN CONTROL
DT
LP
LOW PRESSURE CONTROL
TERMINAL
BOARD
P1
RECEIVER
HEATER
L2
L1
L3
T1
T3
F1
F2
HP
THERMOSTAT
HIGH PRESSURE SWITCH
POWER SUPPLY
208-230 / 60 / 3
L3
T3
L2
T2
L1
T1
DT
DISCHARGE LINE THERMOSTAT
FACTORY COMPONENTS
GRD
CRANK CASE
HEATER
COMPRESSOR
CONTACTOR
L1
L2
L3
T1
T2
T3
DEFROST
HEATERS
CONTACTOR
L1
L2
L3
T1
T2
T3
OPTIONAL FACTORY COMPONENTS
OPTIONAL FIELD COMPONENTS
BLACK
C
S
R
RED
YELLOW
CONDENSING UNIT WIRING, 230V 60Hz 3 Ph,
Liquid Injection Solenoid,
Fan control,
T1 & T2 defrost options
REL
REVISION
MAR. 11, 2011
COMPRESSOR
TERMINAL
WD23-2XT2L
L:\~ Andreea temp\ZZ Low Temp Scroll Datasheets\WORD_datasheets\Outdoor units\VSAG517ZXTHM_preliminary.doc
14/10/2011