Download Tecumseh VSAG513ZXTHM Performance Data Sheet
Transcript
VSAG513ZXTHM TPC___preliminary October 14, 2011 TECUMSEH HERMETIC CONDENSING UNIT Model BOM Air Cooled Application Refrigerant VSAG513ZXTHM 32L3242-2E 3 ¼ HP Low Temp R404A 47.75 46.97 31.58 29.00 26.00 4.50 LIQUID 1/2" SUCTION 7/8" Dim. Enclosure(inch)* VSAG513ZXTHM L W 29.40 47.75 *) Enclosure Mounting Holes, 26.25 x 58.5 Line connections H Suction Liquid 31.58 7/8 Sweat 1/2 Sweat Pumpdown Air flow Oil Ch. Gross weight 90% @ 90oF 33.44 SCFM Oz. Lbs. 4200 55 550 Factory charge 20 psig dry air, MUST BE EVACUATED Ambient Temperatures Evaporator T, °F -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 PSIG 5.5 8.0 10.7 14.0 17.1 19.3 24.5 28.8 33.5 36.5 43.7 BTUH 6200 7100 8200 9300 10600 11900 13400 14900 16600 18400 20300 85°F Watts Head 2850 213 2900 213 2940 213 2980 214 3030 214 3080 215 3130 217 3200 219 3260 222 3340 225 3420 228 o Cond T 92 92 92 92 92 92 93 93 94 95 96 BTUH 5800 6700 7600 8600 9700 11000 12300 13700 15200 16800 18600 95°F Watts Head 3100 235 3150 240 3200 244 3240 248 3290 251 3340 254 3390 258 3450 261 3520 265 3580 269 3660 274 Cond T 100 101 102 103 104 105 106 107 108 109 111 BTUH 5600 6400 7300 8200 9300 10500 11700 13100 14500 16100 17700 100°F Watts Head 3240 251 3290 256 3340 260 3390 264 3440 268 3490 271 3540 275 3600 278 3660 282 3730 286 3810 290 Cond T 104 106 107 108 109 110 111 112 113 114 115 BTUH 5000 5800 6600 7500 8400 9500 10600 11800 13100 14500 16000 110°F Watts Head 3560 286 3620 292 3680 298 3740 302 3790 306 3850 310 3910 314 3970 317 4030 321 4100 324 4180 328 Cond T 114 115 117 118 119 120 121 122 122 123 124 o Performance @ 60 Hz, Return gas 40 F, SubCooling 5 F PRELIMINARY PERFORMANCE DATA L:\~ Andreea temp\ZZ Low Temp Scroll Datasheets\WORD_datasheets\Outdoor units\VSAG513ZXTHM_preliminary.doc 14/10/2011 VSAG513ZXTHM TPC___preliminary October 14, 2011 Parts/Specifications STANDARD Unit BOM Unit MODEL 32L3242-2E VSAG513ZXTHM Refrigeration RANGE Design Pressure Low Design Pressure High Volts - HZ - Ph Voltage Range Min. Circuit Ampacity Max. Fuse Size -40°F to 10°F 181 450 200-230V 3~ 60HZ 180 - 253 16.03 25 Compressor Compressor Compressor Compressor VSAG511ZXT VS122RT-008-A4 80 9.62 MODEL BOM LRA RLA OverLoad Relay Run Capacitor Run Capacitor Rating Start Capacitor Start Capacitor Rating Contactor INTERNAL Unit Drawing Wiring no Fan controls DGU1950-L303 WD23-2XT2L 91014B OPTIONAL Fan Motor Fan Motor Qty Fan Motor RLA Fan Blade Fan Guard Shroud 810S186B40 2 1.9 51528-3 70832 70611-1 High Pressure switch Low Pressure Control Dual Pressure Conrol 84095-2L 84026-2 Condenser Head Master Valve Check Valve Process Valve Liquid Valve Suction Valve 50785-4 70083 56626 Receiver Receiver Qty Accumulator Liquid Filter Sight Glass Suction Filter 51084 1 TK00042000 52000-164D 70084-2 70822-5S CrankCase Heater 14947869 Adjustable Fan Ctrl (A) LAFC-001 Defrost Timer (Tn) LTCG-T2 Receiver Heater (R) LHR-223 Solenoid Valve (S) KSVC-285 Disconnect (D) KDSG-301 BOM INDEX DESCRIPTION 32xYYYY- 2ERA(F)TnDS E Enclosure R Receiver Heater A Adjustable fan control F Fixed fan Control T1 Defrost timer option T2 Defrost timer & Defrost Heaters Contactor D Disconnect S Solenoid liquid Valve (supplied loose) 31529-2 NOTES IMPORTANT: COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR. ALLOW TIME FOR RESET. USE COPPER CONDUCTORS ONLY. (EMPLOYER DES CONDUCTEUERS DE CUIVER SEULEMENT.) 4 3 X N 1 2 DEFROST CONTROL RANCO 8145-xx PRECISION 6145-xx FAN 1 DEFROST HEATERS CONTACTOR COIL FIELD WIRING NOTES 1. ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL APPLICABLE LOCAL AND NATIONAL CODES. 2. CONNECT INCOMING POWER LEADS FROM POWER SUPPLY TO L1, L2, AND L3 IN COMPRESSOR CONTACTOR OR TO L1, L2 AND L3 IN DISCONNECT SWITCH (IF PROVIDED). USE COOPER CONDUCTORS ONLY. (EMPLOYER DES CONDUCTEURS DE CUIVER SEULEMENT.) PROVIDE EQUIPMENT GROUNDING CONDUCTOR. USE 75°C (MIN.) WIRING 3. DEFROST HEATERS LOADS SHOULD NOT BE HIGHER THEN THE MAXIMUM HEATERS LOAD INDICATED ON THE UNIT LABEL. DEFROST HEATERS TO BE CONTROLLED WITH A CONTACTOR AS SHOWN ON THE DIAGRAM. COMPRESSOR CONTACTOR NC AUXILIARY SWITCH FAN 2 GENERAL NOTES: SOLENOID LIQUID INJECTION A. CONTACTOR COIL CIRCUIT IS FACTORY CONNECTED TO 230 V SOURCE IN PANEL AS SHOWN B. COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR. ALLOW TIME FOR RESET. COMPRESSOR CONTACTOR NO AUXILIARY SWITCH FC COMPRESSOR CONTACTOR COIL see note A HP LP FAN CONTROL DT LP LOW PRESSURE CONTROL TERMINAL BOARD P1 RECEIVER HEATER L2 L1 L3 T1 T3 F1 F2 HP THERMOSTAT HIGH PRESSURE SWITCH POWER SUPPLY 208-230 / 60 / 3 L3 T3 L2 T2 L1 T1 DT DISCHARGE LINE THERMOSTAT FACTORY COMPONENTS GRD CRANK CASE HEATER COMPRESSOR CONTACTOR L1 L2 L3 T1 T2 T3 DEFROST HEATERS CONTACTOR L1 L2 L3 T1 T2 T3 OPTIONAL FACTORY COMPONENTS OPTIONAL FIELD COMPONENTS BLACK C S R RED YELLOW CONDENSING UNIT WIRING, 230V 60Hz 3 Ph, Liquid Injection Solenoid, Fan control, T1 & T2 defrost options REL REVISION MAR. 11, 2011 COMPRESSOR TERMINAL WD23-2XT2L L:\~ Andreea temp\ZZ Low Temp Scroll Datasheets\WORD_datasheets\Outdoor units\VSAG513ZXTHM_preliminary.doc 14/10/2011