Download Tecumseh VSAG513ZXTHM Performance Data Sheet

Transcript
VSAG513ZXTHM
TPC___preliminary
October 14, 2011
TECUMSEH HERMETIC
CONDENSING UNIT
Model
BOM
Air Cooled
Application
Refrigerant
VSAG513ZXTHM
32L3242-2E
3 ¼ HP
Low Temp
R404A
47.75
46.97
31.58
29.00
26.00
4.50
LIQUID 1/2"
SUCTION 7/8"
Dim. Enclosure(inch)*
VSAG513ZXTHM
L
W
29.40
47.75
*) Enclosure Mounting Holes, 26.25 x 58.5
Line connections
H
Suction
Liquid
31.58
7/8 Sweat
1/2 Sweat
Pumpdown
Air flow
Oil Ch.
Gross weight
90% @ 90oF
33.44
SCFM
Oz.
Lbs.
4200
55
550
Factory charge 20 psig dry air, MUST BE EVACUATED
Ambient Temperatures
Evaporator
T, °F
-40
-35
-30
-25
-20
-15
-10
-5
0
5
10
PSIG
5.5
8.0
10.7
14.0
17.1
19.3
24.5
28.8
33.5
36.5
43.7
BTUH
6200
7100
8200
9300
10600
11900
13400
14900
16600
18400
20300
85°F
Watts
Head
2850
213
2900
213
2940
213
2980
214
3030
214
3080
215
3130
217
3200
219
3260
222
3340
225
3420
228
o
Cond T
92
92
92
92
92
92
93
93
94
95
96
BTUH
5800
6700
7600
8600
9700
11000
12300
13700
15200
16800
18600
95°F
Watts
Head
3100
235
3150
240
3200
244
3240
248
3290
251
3340
254
3390
258
3450
261
3520
265
3580
269
3660
274
Cond T
100
101
102
103
104
105
106
107
108
109
111
BTUH
5600
6400
7300
8200
9300
10500
11700
13100
14500
16100
17700
100°F
Watts
Head
3240
251
3290
256
3340
260
3390
264
3440
268
3490
271
3540
275
3600
278
3660
282
3730
286
3810
290
Cond T
104
106
107
108
109
110
111
112
113
114
115
BTUH
5000
5800
6600
7500
8400
9500
10600
11800
13100
14500
16000
110°F
Watts
Head
3560
286
3620
292
3680
298
3740
302
3790
306
3850
310
3910
314
3970
317
4030
321
4100
324
4180
328
Cond T
114
115
117
118
119
120
121
122
122
123
124
o
Performance @ 60 Hz, Return gas 40 F, SubCooling 5 F
PRELIMINARY PERFORMANCE DATA
L:\~ Andreea temp\ZZ Low Temp Scroll Datasheets\WORD_datasheets\Outdoor units\VSAG513ZXTHM_preliminary.doc
14/10/2011
VSAG513ZXTHM
TPC___preliminary
October 14, 2011
Parts/Specifications
STANDARD
Unit BOM
Unit MODEL
32L3242-2E
VSAG513ZXTHM
Refrigeration RANGE
Design Pressure Low
Design Pressure High
Volts - HZ - Ph
Voltage Range
Min. Circuit Ampacity
Max. Fuse Size
-40°F to 10°F
181
450
200-230V 3~ 60HZ
180 - 253
16.03
25
Compressor
Compressor
Compressor
Compressor
VSAG511ZXT
VS122RT-008-A4
80
9.62
MODEL
BOM
LRA
RLA
OverLoad
Relay
Run Capacitor
Run Capacitor Rating
Start Capacitor
Start Capacitor Rating
Contactor
INTERNAL
Unit Drawing
Wiring no Fan controls
DGU1950-L303
WD23-2XT2L
91014B
OPTIONAL
Fan Motor
Fan Motor Qty
Fan Motor RLA
Fan Blade
Fan Guard
Shroud
810S186B40
2
1.9
51528-3
70832
70611-1
High Pressure switch
Low Pressure Control
Dual Pressure Conrol
84095-2L
84026-2
Condenser
Head Master Valve
Check Valve
Process Valve
Liquid Valve
Suction Valve
50785-4
70083
56626
Receiver
Receiver Qty
Accumulator
Liquid Filter
Sight Glass
Suction Filter
51084
1
TK00042000
52000-164D
70084-2
70822-5S
CrankCase Heater
14947869
Adjustable Fan Ctrl (A)
LAFC-001
Defrost Timer (Tn)
LTCG-T2
Receiver Heater (R)
LHR-223
Solenoid Valve (S)
KSVC-285
Disconnect (D)
KDSG-301
BOM INDEX DESCRIPTION
32xYYYY- 2ERA(F)TnDS
E Enclosure
R Receiver Heater
A Adjustable fan control
F Fixed fan Control
T1 Defrost timer option
T2 Defrost timer & Defrost Heaters Contactor
D Disconnect
S Solenoid liquid Valve (supplied loose)
31529-2
NOTES
IMPORTANT:
COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD
PROTECTOR. ALLOW TIME FOR RESET.
USE COPPER CONDUCTORS ONLY.
(EMPLOYER DES CONDUCTEUERS DE CUIVER
SEULEMENT.)
4
3
X
N
1
2
DEFROST CONTROL
RANCO
8145-xx
PRECISION 6145-xx
FAN 1
DEFROST
HEATERS
CONTACTOR COIL
FIELD WIRING NOTES
1.
ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL
APPLICABLE LOCAL AND NATIONAL CODES.
2. CONNECT INCOMING POWER LEADS FROM POWER SUPPLY
TO L1, L2, AND L3 IN COMPRESSOR CONTACTOR OR TO L1, L2 AND L3 IN
DISCONNECT SWITCH (IF PROVIDED). USE COOPER CONDUCTORS
ONLY. (EMPLOYER DES CONDUCTEURS DE CUIVER SEULEMENT.)
PROVIDE EQUIPMENT GROUNDING CONDUCTOR.
USE 75°C (MIN.) WIRING
3. DEFROST HEATERS LOADS SHOULD NOT BE HIGHER THEN THE
MAXIMUM HEATERS LOAD INDICATED ON THE UNIT LABEL.
DEFROST HEATERS TO BE CONTROLLED WITH A CONTACTOR AS SHOWN
ON THE DIAGRAM.
COMPRESSOR CONTACTOR
NC AUXILIARY SWITCH
FAN 2
GENERAL NOTES:
SOLENOID
LIQUID INJECTION
A. CONTACTOR COIL CIRCUIT IS FACTORY CONNECTED TO 230 V SOURCE IN
PANEL AS SHOWN
B. COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR.
ALLOW TIME FOR RESET.
COMPRESSOR CONTACTOR
NO AUXILIARY SWITCH
FC
COMPRESSOR
CONTACTOR COIL
see note A
HP
LP
FAN CONTROL
DT
LP
LOW PRESSURE CONTROL
TERMINAL
BOARD
P1
RECEIVER
HEATER
L2
L1
L3
T1
T3
F1
F2
HP
THERMOSTAT
HIGH PRESSURE SWITCH
POWER SUPPLY
208-230 / 60 / 3
L3
T3
L2
T2
L1
T1
DT
DISCHARGE LINE THERMOSTAT
FACTORY COMPONENTS
GRD
CRANK CASE
HEATER
COMPRESSOR
CONTACTOR
L1
L2
L3
T1
T2
T3
DEFROST
HEATERS
CONTACTOR
L1
L2
L3
T1
T2
T3
OPTIONAL FACTORY COMPONENTS
OPTIONAL FIELD COMPONENTS
BLACK
C
S
R
RED
YELLOW
CONDENSING UNIT WIRING, 230V 60Hz 3 Ph,
Liquid Injection Solenoid,
Fan control,
T1 & T2 defrost options
REL
REVISION
MAR. 11, 2011
COMPRESSOR
TERMINAL
WD23-2XT2L
L:\~ Andreea temp\ZZ Low Temp Scroll Datasheets\WORD_datasheets\Outdoor units\VSAG513ZXTHM_preliminary.doc
14/10/2011