Download Tecumseh VSAG511ZXTXM Performance Data Sheet
Transcript
VSAG511ZXTXM TPC___preliminary October 14, 2011 TECUMSEH HERMETIC CONDENSING UNIT Model BOM Air Cooled Application Refrigerant VSAG511ZXTXM 32T2642-2 2 ¾ HP Low Temp R404A 25.00 19.44 16.00 1.25 LIQUID 1/2" SUCTION 7/8" 31.50 Dimensions (inch)* VSAG511ZXTXM L 25.00 *) Mounting Holes, 16.00 x 31.50 Line connections Pumpdown W H Suction Liquid 33.50 19.44 7/8 Sweat 1/2 Sweat o 90% @ 90 F 20.44 Air flow Oil Ch. Gross weight SCFM Oz. Lbs. 1525 55 200 Factory charge 20 psig dry air, MUST BE EVACUATED Ambient Temperatures Evaporator T, °F -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 PSIG 5.5 8.0 10.7 14.0 17.1 19.3 24.5 28.8 33.5 36.5 43.7 BTUH 5000 5900 6800 7800 8900 10000 11100 12400 13600 15000 16400 80°F Watts Head 1990 197 2070 201 2140 205 2210 208 2290 213 2360 217 2430 221 2510 226 2600 232 2680 238 2780 245 o Cond T 88 89 90 92 93 94 96 97 99 101 103 BTUH 4700 5400 6200 7100 8000 9000 10100 11200 12400 13600 14900 90°F Watts Head 2140 230 2220 233 2290 237 2370 241 2440 245 2520 249 2600 254 2680 259 2770 264 2860 271 2960 277 Cond T 98 99 100 101 103 104 105 107 108 110 112 BTUH 4600 5300 6000 6700 7600 8500 9400 10500 11500 12700 13900 100°F Watts Head 2300 264 2380 267 2460 271 2540 274 2620 278 2700 282 2780 287 2860 292 2950 298 3050 304 3160 311 Cond T 108 109 110 111 112 113 114 115 117 118 120 BTUH 4200 4800 5400 6100 6800 7600 8500 9500 10500 11600 12700 110°F Watts Head 2490 301 2570 304 2650 308 2730 311 2810 315 2890 319 2970 323 3060 328 3160 334 3260 340 3360 347 Cond T 118 118 119 120 121 122 123 124 125 127 128 o Performance @ 60 Hz, Return gas 40 F, SubCooling 5 F PRELIMINARY PERFORMANCE DATA L:\~ Andreea temp\ZZ Low Temp Scroll Datasheets\WORD_datasheets\Indoor units\VSAG511ZXTXM_preliminary.doc 14/10/2011 VSAG511ZXTXM TPC___preliminary October 14, 2011 Parts/Specifications Unit BOM Unit MODEL 32T2642-2 VSAG511ZXTXM Refrigeration RANGE Design Pressure Low Design Pressure High Volts - HZ - Ph Voltage Range Min. Circuit Ampacity Max. Fuse Size -40°F to 10°F 181 450 200-230V 3~ 60HZ 180 - 253 13.90 25 Compressor Compressor Compressor Compressor VSAG494ZXT VS121RT-008-A4 80 10.00 MODEL BOM LRA RLA OverLoad Relay Run Capacitor Run Capacitor Rating Start Capacitor Start Capacitor Rating Contactor INTERNAL 91014B Unit Drawing Wiring Diagram DGU1950-12 WD23-2FL Fan Motor Fan Motor Qty Fan Motor RLA Fan Blade Fan Guard Shroud 810F050C20 2 0.7 51568-1 70831 70648-2 High Pressure switch Low Pressure Control Dual Pressure Conrol 84095-2 84026-2 Condenser Head Master Valve Check Valve Process Valve Liquid Valve Suction Valve 50858 Receiver Receiver Qty Accumulator Liquid Filter Sight Glass Suction Filter 51099-2L 1 TK00042000 52000-084D 70084-2 70822-5S 31529-2 CrankCase Heater NOTES IMPORTANT: COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR. ALLOW TIME FOR RESET. USE COPPER CONDUCTORS ONLY. (EMPLOYER DES CONDUCTEUERS DE CUIVER SEULEMENT.) FIELD WIRING NOTES 1. ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL APPLICABLE LOCAL AND NATIONAL CODES. 2. CONNECT INCOMING POWER LEADS FROM POWER SUPPLY TO L1, L2, AND L3 IN COMPRESSOR CONTACTOR OR TO L1, L2 AND L3 IN DISCONNECT SW ITCH (IF PROVIDED). USE COOPER CONDUCTORS ONLY. (EMPLOYER DES CONDUCTEURS DE CUIVER SEULEMENT.) PROVIDE EQUIPMENT GROUNDING CONDUCTOR. USE 75°C (MIN.) WIRING 3. IF REQUIRED INSTALL SYSTEM REMOTE CONTROL BETW EEN P1 AND P2 IN TERMINAL BLOCK AND REMOVE THE JUMPER FAN 1 FAN 2 GENERAL NOTES: SOLENOID LIQUID INJECTION A. CONTACTOR COIL CIRCUIT IS FACTORY CONNECTED TO 230 V SOURCE IN PANEL AS SHOWN B. COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR. ALLOW TIME FOR RESET. COMPRESSOR CONTACTOR NO AUXILIARY SW ITCH FFC1 (FFC2) COMPRESSOR CONTACTOR COIL see note A HP DT FFC1 FFC2 LP LOW PRESSURE CONTROL TERMINAL BOARD P1 RECEIVER HEATER FAN CONTROL 1 (2) LP P3 P2 HP THERMOSTAT HIGH PRESSURE SWITCH POWER SUPPLY 208-230 / 60 / 3 L3 T3 L2 T2 L1 T1 DT DISCHARGE LINE THERMOSTAT FACTORY COMPONENTS GRD CRANK CASE HEATER COMPRESSOR CONTACTOR L1 L2 L3 T1 T2 T3 OPTIONAL FACTORY COMPONENTS OPTIONAL FIELD COMPONENTS COMPRESSOR TERMINAL BLACK R RED YELLOW REL REVISION L:\~ Andreea temp\ZZ Low Temp Scroll Datasheets\WORD_datasheets\Indoor units\VSAG511ZXTXM_preliminary.doc DEC 21, 2010 C S CONDENSING UNIT WIRING, 230V 60Hz 3 Ph, Liquid Injection Solenoid, Fan control, WD23-2FL 14/10/2011