AJA7490ZXDHN TPC___preliminary October 19, 2011 TECUMSEH HERMETIC CONDENSING UNIT Model BOM Air Cooled Application Refrigerant AJA7490ZXDHN 32L1801-2E 1 HP Medium Temp R404A 36.25 35.38 25.50 26.08 23.50 4.36 SUCTION 5/8" LIQUID 3/8" Dim. Enclosure(inch)* L W H Model AJA7490ZXDHN 31.50 40.50 Line connections Suction Liquid 26.75 5/8 Pumpdown o 90% @ 90 F 20.16 3/8 Air flow SCFM Oil Ch. Oz. Gross weight Lbs. 1800 22 300 *) Enclosure Mounting Holes, 38.5 x 25.5 Factory charge 20 psig dry air, MUST BE EVACUATED Ambient Temeratures Evaporator o F -10 -5 0 5 10 15 20 25 30 35 Psig 23.2 27.5 32.1 37.0 42.4 48.2 54.5 61.2 68.4 76.1 o BTUH 4900 5800 6800 7800 8900 10000 11100 12200 13300 14400 80 F Watts Head Cond T 1290 203 89 1360 205 90 1430 208 91 1490 212 92 1550 215 94 1610 220 95 1670 224 97 1740 229 98 1810 235 100 1890 241 102 o o BTUH 3800 4600 5600 6500 7500 8600 9700 10800 11900 13000 95 F Watts Head Cond T 1250 251 104 1340 253 105 1430 256 106 1510 260 107 1590 264 108 1660 269 109 1740 274 111 1810 280 112 1890 286 114 1980 293 116 o o BTUH 3400 4200 5100 6000 7000 8100 9100 10200 11400 12500 o 100 F Watts Head Cond T 1230 269 109 1330 271 110 1420 274 110 1510 278 111 1590 282 113 1670 287 114 1750 292 115 1840 298 117 1920 304 119 2010 311 120 o o BTUH 2500 3200 4100 5000 6000 7000 8100 9200 10300 11400 110 F Watts Head Cond T 1160 308 119 1280 309 119 1390 312 120 1490 315 121 1590 319 122 1690 323 123 1780 328 124 1870 334 126 1970 341 127 2070 348 129 o Performance @ 60 Hz ; Return Gas Temperature 20 F max superheat above 20 F evap, 40 F max below 20 F evap ; --- SubCooling 5 F PRELIMINARY PERFORMANCE DATA L:\~ Andreea temp\ZZ Follett Datasheets\TecDataSheet Info\WORD_datasheets\AJA7490ZXDHN_preliminary.doc 19/10/2011 AJA7490ZXDHN TPC___preliminary October 19, 2011 Parts/Specifications STANDARD Unit BOM Unit MODEL 32L1801-2E AJA7490ZXDHN Refrigeration RANGE Design Pressure Low Design Pressure High Volts - HZ - Ph Voltage Range Min. Circuit Ampacity Max. Fuse Size -10°F to 35°F 181 450 208-230V ~ 60HZ 187 - 254 10.70 15 Compressor MODEL Compressor BOM Compressor LRA Compressor RLA AJA7490ZXD AJ779ET-361-A4 40.6 6.90 OverLoad Relay Run Capacitor Run Capacitor Rating Start Capacitor Start Capacitor Rating Contactor 8300MRAC37 14948497 85PR370F21 45 MFD, 370 V 85PS330C24 88-108 MFD, 330 V 91014B Unit Drawing Wiring Diagram DGU1758-L101 WD21-2XT2 OPTIONAL Fan Motor Fan Motor Qty Fan Motor RLA Fan Blade Fan Guard Shroud 810F050C20 2 0.7 51568-1 70831 70648-2 High Pressure switch Low Pressure Control Dual Pressure Conrol 84095-2L 84026-2 Rec. Heater (R option) Solenoid Valve (loose) Disconnect (D option) Condenser Head Master Valve Check Valve Process Valve Liquid Valve Suction Valve 50855-1 70083-1 56626 Wiring with F option Wiring with A option Receiver Receiver Qty Accumulator Liquid Filter Sight Glass Suction Filter 51099-2L 1 CrankCase Heater 92123-1 Fix.Fan Switch #1 (F opt.) 84132-01 Fix.Fan Switch #2 (F opt.) Adjus. Fan Ctrl. (A opt.) Defrost Clock (Tn option) Defrost Heaters Contactor BOM INDEX DESCRIPTION 56500-K06 56500-K10 32xYYYY- 2ERA(F)TnDS E Enclosure R Receiver Heater A Adjustable fan control F Fixed fan Control T1 Defrost timer option T2 Defrost timer & Defrost Heaters Contactor D Disconnect S Solenoid liquid Valve (supplied loose) 70081-3 70084 70822-6S NOTES IMPORTANT: FIELD INSTALLED SOLENOID & THERMOSTAT COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR. ALLOW TIME FOR RESET. USE COPPER CONDUCTORS ONLY. (EMPLOYER DES CONDUCTEUERS DE CUIVER SEULEMENT.) ROOM THERMOSTAT Solenoid Valve 4 3 X DEFROST CONTROL RANCO 8145-xx PRECISION 6145-xx N 1 2 FAN 1 DEFROST HEATERS CONTACTOR COIL WD21-2AT2 FIELD WIRING NOTES 1. ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL APPLICABLE LOCAL AND NATIONAL CODES. 2. CONNECT INCOMING POWER LEADS FROM POWER SUPPLY TO L1 AND L3 IN COMPRESSOR CONTACTOR (L1 AND L2 IF TWO POLE CONTACTOR) OR TO L1 AND L3 IN DISCONNECT SWITCH (IF PROVIDED). USE COOPER CONDUCTORS ONLY. (EMPLOYER DES CONDUCTEURS DE CUIVER SEULEMENT.) PROVIDE EQUIPMENT GROUNDING CONDUCTOR. USE 75°C (MIN.) WIRING 3. PLACE JUMPER ACCROSS P1 AND L1 IN TERMINAL BOARD IF NO OTHER CONTROLLING DEVICE IS INSTALLED. 4. DEFROST HEATERS LOADS SHOULD NOT BE HIGHER THEN THE MAXIMUM HEATERS LOAD INDICATED ON THE UNIT LABEL. FAN 2 GENERAL NOTES: COMPRESSOR CONTACTOR NC AUXILIARY SWITCH COMPRESSOR CONTACTOR COIL see note A HP A. CONTACTOR COIL CIRCUIT IS FACTORY CONNECTED TO 230 V SOURCE IN LP PANEL AS SHOWN B. WITH ANY T.P.Co. APPROVED START RELAY USED, CONNECT LEADS TO SAME NUMBERED TERMINALS REGARDLESS OF LOCATION C. COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR. ALLOW TIME FOR RESET. AFC AFC TERMINAL BOARD RECEIVER HEATER P1 L1 L2 L3 T1 T3 F1 F2 LP ADJUSTABLE FAN CONTROL LOW PRESSURE CONTROL HEATER THERMOSTAT POWER SUPPLY 230-60-1 L3 T3 L2 T2 L1 T1 HP HIGH PRESSURE SWITCH FACTORY COMPONENTS POTENTIAL RELAY see note B GRD OPTIONAL FACTORY COMPONENTS COMPRESSOR CONTACTOR L1 L2 L3 L1 L2 L3 T1 T2 T3 T1 T2 T3 4 5 6 1 CONDENSING UNIT WIRING, 230V 60Hz 1 Ph, Adjustable fan control, T1 & T2 defrost options BLACK C S OPTIONAL FIELD COMPONENTS 2 DEFROST HEATERS CONTACTOR COMPRESSOR TERMINAL R START CAPACITOR WITH BLEEDER RESISTOR RED YELLOW BLACK RED YELLOW RUN CAPACITOR B REVISION L:\~ Andreea temp\ZZ Follett Datasheets\TecDataSheet Info\WORD_datasheets\AJA7490ZXDHN_preliminary.doc NOV 06, 2009 CRANK CASE HEATER WD21-2AT2 19/10/2011