Download Tecumseh AVA9522ZXTHN Performance Data Sheet
Transcript
AVA9522ZXTHN TPC___REV 1 March 21, 2012 TECUMSEH HERMETIC CONDENSING UNIT Model BOM Air Cooled Application Refrigerant AVA9522ZXTHN 32L3152-2E 2 ¾ HP Commercial Temp R404A 36.25 35.38 25.50 23.50 26.08 4.24 Dim. Enclosure(inch)* L W H Model Line connections Suction Liquid AVA9522ZXTHN 31.50 40.50 26.75 *) Enclosure Mounting Holes, 38.5 x 25.5 Factory charge 20 psig dry air, MUST BE EVACUATED Evaporator o F -10 -5 0 5 10 15 20 25 30 35 40 45 50 55 Psig 23.2 27.5 32.1 37.0 42.4 48.2 54.5 61.2 68.4 76.1 84.4 93.2 103.0 113.0 7/8 o BTUH 10500 12100 13800 15600 17500 19500 21700 24000 26400 29000 31800 34700 37800 41100 80 F Watts Head Cond T 2460 211 90 2630 217 92 2800 223 94 2980 230 95 3150 237 97 3330 245 99 3510 253 100 3700 263 102 3900 273 104 4110 284 106 4330 296 109 4570 309 111 4820 323 114 5090 339 117 o BTUH 9300 10700 12100 13700 15300 17100 18900 20900 23100 25300 27700 30300 33000 35900 Pumpdown o 90% @ 90 F 20.45 1/2 Air flow SCFM Oil Ch. Oz. Gross weight Lbs. 1800 54 340 Ambient Temeratures o o 95 F 100 F Watts Head Cond T BTUH Watts Head Cond T 2450 256 104 8600 2440 273 109 2650 262 106 9900 2650 279 110 2850 269 107 11300 2860 285 112 3050 275 109 12800 3070 292 113 3250 283 110 14400 3280 299 114 3460 291 112 16100 3490 307 116 3660 299 113 17900 3700 316 117 3880 308 115 19800 3930 325 119 4100 319 117 21800 4150 335 121 4330 329 119 24000 4390 345 123 4570 341 121 26300 4640 357 125 4830 354 123 28800 4910 370 127 5100 368 126 31400 5180 384 129 5390 384 129 34200 5480 399 132 o o o o 110 F BTUH Watts Head Cond T 7000 2400 308 118 8300 2630 314 119 9600 2860 321 121 11000 3080 327 122 12500 3310 334 123 14100 3540 342 125 15800 3770 350 126 17600 4010 359 128 19500 4250 368 129 21600 4510 378 131 23800 4770 390 133 26100 5050 402 135 28500 5340 415 137 31100 5650 430 140 o Performance @ 60 Hz ; Return Gas Temperature 20 F max superheat above 20 F evap, 40 F max below 20 F evap ; --- SubCooling 5 F PRELIMINARY PERFORMANCE DATA L:\~ Andreea temp\ZZ Follett Datasheets\TecDataSheet Info\WORD_datasheets\AVA9522ZXTHN_REV1.doc 21/03/2012 AVA9522ZXTHN TPC___REV 1 March 21, 2012 Parts/Specifications STANDARD Unit BOM Unit MODEL 32L3152-2E AVA9522ZXTHN Refrigeration RANGE Design Pressure Low Design Pressure High Volts - HZ - Ph Voltage Range Min. Circuit Ampacity Max. Fuse Size -10°F to 45°F 181 450 200-230V 3~ 60HZ 180 - 254 21.24 35 Compressor MODEL Compressor BOM Compressor LRA Compressor RLA AV203RT-012-A2 AVA9522ZXT 74 10.30 OverLoad Relay Run Capacitor Run Capacitor Rating Start Capacitor Start Capacitor Rating Contactor 91014B Unit Drawing Wiring Diagram DGU1920-L102 WD23-2FM OPTIONAL Fan Motor Fan Motor Qty Fan Motor RLA Fan Blade Fan Guard Shroud 810F050C20 2 0.7 51568 70831 70648-2 High Pressure switch Low Pressure Control Dual Pressure Conrol 84095-2L 84026-2 Condenser Head Master Valve Check Valve Process Valve Liquid Valve Suction Valve 50858-1 70083-1 56626 31583-1 56500-K08 56500-K14 Receiver Receiver Qty Accumulator Liquid Filter Sight Glass Suction Filter 51099-2L 1 CrankCase Heater 90699 Fix.Fan Switch #1 (F opt.) Fix.Fan Switch #2 (F opt.) Adjus. Fan Ctrl. (A opt.) Defrost Clock (Tn option) Defrost Heaters Contactor Rec. Heater (R option) Solenoid Valve (loose) Disconnect (D option) 84132-01 Wiring with F option Wiring with A option WD23-2AT2 Phase Monitor, ICM402 900-10026 BOM INDEX DESCRIPTION 32xYYYY- 2ERA(F)TnDS E Enclosure R Receiver Heater A Adjustable fan control F Fixed fan Control T1 Defrost timer option T2 Defrost timer & Defrost Heaters Contactor D Disconnect S Solenoid liquid Valve (supplied loose) 52000-084D 70084-2 70822-5S NOTES IMPORTANT: COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR. ALLOW TIME FOR RESET. USE COPPER CONDUCTORS ONLY. (EMPLOYER DES CONDUCTEUERS DE CUIVER SEULEMENT.) FIELD WIRING NOTES 1. ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL APPLICABLE LOCAL AND NATIONAL CODES. 2. CONNECT INCOMING POWER LEADS FROM POWER SUPPLY TO L1, L2, AND L3 IN COMPRESSOR CONTACTOR OR TO L1, L2 AND L3 IN DISCONNECT SWITCH (IF PROVIDED). USE COOPER CONDUCTORS ONLY. (EMPLOYER DES CONDUCTEURS DE CUIVER SEULEMENT.) PROVIDE EQUIPMENT GROUNDING CONDUCTOR. USE 75°C (MIN.) WIRING FAN 1 FAN 2 GENERAL NOTES: A. CONTACTOR COIL CIRCUIT IS FACTORY CONNECTED TO 230 V SOURCE IN TO "Y-OUT" AT PHASE MONITOR COMPRESSOR CONTACTOR COIL see note A HP LP A B D.T. C TERMINAL BOARD P1 PANEL AS SHOWN B. COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR. ALLOW TIME FOR RESET. TO "230 VAC" AT PHASE MONITOR L1 FFC TO "C" AT PHASE MONITOR L2 AFC L3 T1 T3 F1 F2 LP POWER SUPPLY 230-60-3 LOW PRESSURE CONTROL HP L3 T3 L2 T2 L1 TO "P1" AT TERMINAL BOARD T1 ADJUSTABLE FAN CONTROL HIGH PRESSURE SWITCH TO "L2" AT TERMINAL C BOARD A D.T. B TO "L1" AT TERMINAL BOARD DISCHARGE THERMOSTAT GRD FACTORY COMPONENTS CRANK CASE HEATER L1 L2 L3 T1 T2 T3 Y C 115 230 VAC VAC OPTIONAL FACTORY COMPONENTS ICM402 3 PHASE MONITOR COMPRESSOR TERMINAL L1 L2 L3 BLACK R CONDENSING UNIT WIRING, 230V 60Hz 3 Ph, fixed fan control, PHASE MONITOR OPTION RED YELLOW REVISION L:\~ Andreea temp\ZZ Follett Datasheets\TecDataSheet Info\WORD_datasheets\AVA9522ZXTHN_REV1.doc AUG. 18, 2009 C S YOUT WD23-2FM 21/03/2012