Download Tecumseh AVA9522ZXTHN Performance Data Sheet

Transcript
AVA9522ZXTHN
TPC___REV 1
March 21, 2012
TECUMSEH HERMETIC
CONDENSING UNIT
Model
BOM
Air Cooled
Application
Refrigerant
AVA9522ZXTHN
32L3152-2E
2 ¾ HP
Commercial Temp
R404A
36.25
35.38
25.50
23.50
26.08
4.24
Dim. Enclosure(inch)*
L
W
H
Model
Line connections
Suction
Liquid
AVA9522ZXTHN
31.50 40.50 26.75
*) Enclosure Mounting Holes, 38.5 x 25.5
Factory charge 20 psig dry air, MUST BE EVACUATED
Evaporator
o
F
-10
-5
0
5
10
15
20
25
30
35
40
45
50
55
Psig
23.2
27.5
32.1
37.0
42.4
48.2
54.5
61.2
68.4
76.1
84.4
93.2
103.0
113.0
7/8
o
BTUH
10500
12100
13800
15600
17500
19500
21700
24000
26400
29000
31800
34700
37800
41100
80 F
Watts Head Cond T
2460
211
90
2630
217
92
2800
223
94
2980
230
95
3150
237
97
3330
245
99
3510
253
100
3700
263
102
3900
273
104
4110
284
106
4330
296
109
4570
309
111
4820
323
114
5090
339
117
o
BTUH
9300
10700
12100
13700
15300
17100
18900
20900
23100
25300
27700
30300
33000
35900
Pumpdown
o
90% @ 90 F
20.45
1/2
Air flow
SCFM
Oil Ch.
Oz.
Gross weight
Lbs.
1800
54
340
Ambient Temeratures
o
o
95 F
100 F
Watts Head Cond T BTUH Watts Head Cond T
2450
256
104
8600 2440
273
109
2650
262
106
9900 2650
279
110
2850
269
107 11300 2860
285
112
3050
275
109 12800 3070
292
113
3250
283
110 14400 3280
299
114
3460
291
112 16100 3490
307
116
3660
299
113 17900 3700
316
117
3880
308
115 19800 3930
325
119
4100
319
117 21800 4150
335
121
4330
329
119 24000 4390
345
123
4570
341
121 26300 4640
357
125
4830
354
123 28800 4910
370
127
5100
368
126 31400 5180
384
129
5390
384
129 34200 5480
399
132
o
o
o
o
110 F
BTUH Watts Head Cond T
7000 2400
308
118
8300 2630
314
119
9600 2860
321
121
11000 3080
327
122
12500 3310
334
123
14100 3540
342
125
15800 3770
350
126
17600 4010
359
128
19500 4250
368
129
21600 4510
378
131
23800 4770
390
133
26100 5050
402
135
28500 5340
415
137
31100 5650
430
140
o
Performance @ 60 Hz ; Return Gas Temperature 20 F max superheat above 20 F evap, 40 F max below 20 F evap ; --- SubCooling 5 F
PRELIMINARY PERFORMANCE DATA
L:\~ Andreea temp\ZZ Follett Datasheets\TecDataSheet Info\WORD_datasheets\AVA9522ZXTHN_REV1.doc
21/03/2012
AVA9522ZXTHN
TPC___REV 1
March 21, 2012
Parts/Specifications
STANDARD
Unit BOM
Unit MODEL
32L3152-2E
AVA9522ZXTHN
Refrigeration RANGE
Design Pressure Low
Design Pressure High
Volts - HZ - Ph
Voltage Range
Min. Circuit Ampacity
Max. Fuse Size
-10°F to 45°F
181
450
200-230V 3~ 60HZ
180 - 254
21.24
35
Compressor MODEL
Compressor BOM
Compressor LRA
Compressor RLA
AV203RT-012-A2
AVA9522ZXT
74
10.30
OverLoad
Relay
Run Capacitor
Run Capacitor Rating
Start Capacitor
Start Capacitor Rating
Contactor
91014B
Unit Drawing
Wiring Diagram
DGU1920-L102
WD23-2FM
OPTIONAL
Fan Motor
Fan Motor Qty
Fan Motor RLA
Fan Blade
Fan Guard
Shroud
810F050C20
2
0.7
51568
70831
70648-2
High Pressure switch
Low Pressure Control
Dual Pressure Conrol
84095-2L
84026-2
Condenser
Head Master Valve
Check Valve
Process Valve
Liquid Valve
Suction Valve
50858-1
70083-1
56626
31583-1
56500-K08
56500-K14
Receiver
Receiver Qty
Accumulator
Liquid Filter
Sight Glass
Suction Filter
51099-2L
1
CrankCase Heater
90699
Fix.Fan Switch #1 (F opt.)
Fix.Fan Switch #2 (F opt.)
Adjus. Fan Ctrl. (A opt.)
Defrost Clock (Tn option)
Defrost Heaters Contactor
Rec. Heater (R option)
Solenoid Valve (loose)
Disconnect (D option)
84132-01
Wiring with F option
Wiring with A option
WD23-2AT2
Phase Monitor, ICM402
900-10026
BOM INDEX DESCRIPTION
32xYYYY- 2ERA(F)TnDS
E Enclosure
R Receiver Heater
A Adjustable fan control
F Fixed fan Control
T1 Defrost timer option
T2 Defrost timer & Defrost Heaters Contactor
D Disconnect
S Solenoid liquid Valve (supplied loose)
52000-084D
70084-2
70822-5S
NOTES
IMPORTANT:
COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD
PROTECTOR. ALLOW TIME FOR RESET.
USE COPPER CONDUCTORS ONLY.
(EMPLOYER DES CONDUCTEUERS DE CUIVER
SEULEMENT.)
FIELD WIRING NOTES
1.
ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL
APPLICABLE LOCAL AND NATIONAL CODES.
2. CONNECT INCOMING POWER LEADS FROM POWER SUPPLY
TO L1, L2, AND L3 IN COMPRESSOR CONTACTOR OR TO L1, L2 AND L3 IN
DISCONNECT SWITCH (IF PROVIDED). USE COOPER CONDUCTORS
ONLY. (EMPLOYER DES CONDUCTEURS DE CUIVER SEULEMENT.)
PROVIDE EQUIPMENT GROUNDING CONDUCTOR.
USE 75°C (MIN.) WIRING
FAN 1
FAN 2
GENERAL NOTES:
A. CONTACTOR COIL CIRCUIT IS FACTORY CONNECTED TO 230 V SOURCE IN
TO "Y-OUT"
AT PHASE
MONITOR
COMPRESSOR
CONTACTOR COIL
see note A
HP
LP
A
B
D.T.
C
TERMINAL
BOARD
P1
PANEL AS SHOWN
B. COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR.
ALLOW TIME FOR RESET.
TO "230 VAC"
AT PHASE
MONITOR
L1
FFC
TO "C"
AT PHASE
MONITOR
L2
AFC
L3
T1
T3
F1
F2
LP
POWER SUPPLY
230-60-3
LOW PRESSURE CONTROL
HP
L3
T3
L2
T2
L1
TO "P1"
AT TERMINAL
BOARD
T1
ADJUSTABLE FAN CONTROL
HIGH PRESSURE SWITCH
TO "L2"
AT TERMINAL
C BOARD
A
D.T.
B
TO "L1"
AT TERMINAL
BOARD
DISCHARGE THERMOSTAT
GRD
FACTORY COMPONENTS
CRANK CASE
HEATER
L1
L2
L3
T1
T2
T3
Y
C
115 230
VAC VAC
OPTIONAL FACTORY COMPONENTS
ICM402
3 PHASE
MONITOR
COMPRESSOR
TERMINAL
L1 L2 L3
BLACK
R
CONDENSING UNIT WIRING, 230V 60Hz 3 Ph,
fixed fan control,
PHASE MONITOR OPTION
RED
YELLOW
REVISION
L:\~ Andreea temp\ZZ Follett Datasheets\TecDataSheet Info\WORD_datasheets\AVA9522ZXTHN_REV1.doc
AUG. 18, 2009
C
S
YOUT
WD23-2FM
21/03/2012