Download Dell Force10 Configuration manual
Transcript
– For a port channel interface, enter the keyword port-channel then a number from 1 to 128. – For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. – For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. – For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. To view the configuration, use the show running-config ntp command in EXEC privilege mode (refer to the example in Configuring NTP Authentication). Configuring NTP Authentication NTP authentication and the corresponding trusted key provide a reliable means of exchanging NTP packets with trusted time sources. NTP authentication begins when the first NTP packet is created following the configuration of keys. NTP authentication in the Dell Networking OS uses the message digest 5 (MD5) algorithm and the key is embedded in the synchronization packet that is sent to an NTP time source. To configure NTP authentication, use the following commands. 1. Enable NTP authentication. CONFIGURATION mode ntp authenticate 2. Set an authentication key. CONFIGURATION mode ntp authentication-key number md5 key Configure the following parameters: 3. • number: the range is from 1 to 4294967295. This number must be the same as the number in the ntp trusted-key command. • key: enter a text string. This text string is encrypted. Define a trusted key. CONFIGURATION mode ntp trusted-key number Configure a number from 1 to 4294967295. The number must be the same as the number used in the ntp authentication-key command. 4. Configure an NTP server. CONFIGURATION mode ntp server ip-address [key keyid] [prefer] [version number] Configure the IP address of a server and the following optional parameters: • key keyid: configure a text string as the key exchanged between the NTP server and the client. • prefer: enter the keyword prefer to set this NTP server as the preferred server. • version number: enter a number as the NTP version. The range is from 1 to 3. System Time and Date 885
Related documents
Dell Force10 S4810P Configuration manual
Dell Force10 Z9000 Configuration manual
Dell Networking S6000 Configuration manual
Dell Networking Z9500 Configuration manual
Dell S5000 Specifications
Dell Force10 Z9000 Addendum
Dell PowerEdge M IO Aggregator Configuration manual
Dell Force10 S4810P Command Line Reference Guide
Dell Networking S5000 Installation Manual
Dell PowerEdge Configuration Guide for the M I/O Aggregator 9.9(0.0)
RFM/data/sn8200_snic_uart_serial_interface_user_manual?
NETGEAR 8800 Chassis Switch CLI Manual
Dell Networking S6000 Command Line Reference Guide
Dell PowerEdge NM176 User`s guide
Dell PowerEdge M IO Aggregator User's Manual
BrocadeVCSFabric-TestCases_V1-0_2013-02
Dell Force10 Command Line Reference Guide
Dell PowerEdge M IO Aggregator Owner`s manual
Dell PowerEdge M IO Aggregator Owner`s manual