M_max upper scal
p1528 [C]
(1524[0])
M_max up/mot scal
-2000.0 ... 2000.0 [%]
p1524 [D] (100.0)
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 01/2011
Lower torque limit
3
<1>
<2>
4
!
!
<2>
[6640.1]
M_max lower scal
p1529 [C]
(1525[0])
M_max lower scal
-2000.0 ... 2000.0 [%]
p1525 [D] (100.0)
Danger: Negative values at <1>
positive values at <2>
1
Vector control
Upper/lower torque limit
M_max low w/o offs [Nm]
r1527
M_max lower
p1523 [C]
(1521[0])
M_max lower
-20000000.00 ... 1000000.00 [Nm]
p1521 [D] (0.00)
M
n
[6640.1]
2
represent a minimum torque for the other torque direction and can cause the motor to accelerate uncontrollably.
3
4
5
6
FP_6630_97_51.vsd
13.12.2010
V4.4
7
Function diagram
G120 CU230P-2
8
- 6630 -
Function diagrams
6630 – Upper/lower torque limit
M_max upper
-1000000.00 ... 20000000.00 [Nm]
p1520 [D] (0.00)
2
M_max up w/o offs [Nm]
r1526
M_max upper
p1522 [C]
(1520[0])
Vector control
Fig. 2-81
2-590
Upper torque limit