Download Bosch GREENSTAR PLUS Technical data
Transcript
APPENDIX 13.6 ALTERNATIVE PIPE WORK LENGTHS AND T Additional pipe length [m] 20 10 6 0 20 10 6 0 Maximum flow rate [l/min] 15.3 16.3 16.8 17.6 15.3 16.3 16.8 17.6 Heating output [kW] 21.86 23.29 24.00 25.14 23.96 25.03 25.80 27.03 T [K] 20 20 20 20 21.5 21.5 21.5 21.5 Residual pressure [mbar] 200 200 200 200 200 200 200 200 Table 50 : Alternative T between the heating system flow and return based on additional pipe length Heating output [kW] 28 30 28 30 28 30 28 30 Additional pipe length [m] Maximum flow rate [l/min] 20 15.3 10 16.3 6 16.8 0 17.6 T [K] 25.62 27.45 24.05 25.77 23.33 25.00 22.27 23.86 Table 51 : Alternative T between the heating system flow and return based on heating output The maximum length of refrigerant pipework must be maximum 30m each way and therefore must be taken into account when extending CH system pipework. 6 720 803 687 (2012/11) 89