Download Bosch GREENSTAR PLUS Technical data
Transcript
COMMISSIONING 6.2.11 VENTING THE HYBRID MANAGER 6.2.12 SETTING THE BYPASS VALVE NOTICE: Damage through pump running dry! ▶ Regularly check the water level and top up heating system with water, if required. Once the bypass valve is set it is recommended to lock the valve setting in place. Set the bypass valve subject to the selected pump curve: We recommend the installation of a manual air vent valve near the heating water return of the hybrid manager to enable the hybrid manager to be vented. Airlocks in the pump can result in noise, vent the circulating pump to remove any air lock. • Speed stage I bypass setting = 0.05 bar • Speed stage II bypass setting = 0.18 bar • Speed stage III bypass setting = 0.45 bar ▶ Select the determined bypass setting at the adjusting part of the bypass valve. ▶ Open manual air vent valve. ▶ Close the manual air vent valve as soon as there is sign of water present. This prevents air being drawn into the system again. ▶ Select Hybrid manager circulating pump speed stage III. ▶ Select the “Function test” menu at the FW200 programming unit, in order to operate the Hybrid manager circulating pump ( Operating instructions of the FW200 programming unit). ▶ Let the Hybrid manager circulating pump run for a short time, subject to system layout and size. ▶ Stop the Hybrid manager circulating pump via the “Function test” menu. ▶ Open manual air vent valve. Reinstate the specified system pressure if a large amount of air escapes from the system. 6 720 646 970-118.1ITL Fig. 50 Setting the bypass valve 6.2.13 SETTING PARAMETERS FOR OPTIMISING ENERGY USE AND COSTS OF THE HYBRID SYSTEM These parameters can be set either via the FW200 programming unit or via the hybrid control module. These values are transferred and overwritten respectively. The following explains the setting using the FW200 programming unit. For information on setting at the hybrid control module, see chapter 6.2.23. ▶ Close the manual air vent valve. ▶ Repeat steps 3 to 8 until the system has been completely vented. ▶ After venting the system, adjust the pump ( section 6.2.9). The hybrid system offers a choice of different operating modes: Operating mode Environmental factors Costs Environment and costs Changeover threshold Description With CO2-optimised mode, the system control decides when operating the air to water heat pump or the condensing boiler results in the greatest CO2 reduction. With the cost-optimised operation, the system control decides on the basis of current energy prices. Rising gas prices result in longer operation of the air to water heat pump, whilst rising electricity prices result in longer operation of the condensing boiler. Mixed operation taking environmental factors and costs into account. Environmental and financial aspects are taken into consideration. With weather-compensated operation, the condensing boiler starts from a set outside temperature. Table 12 Overview of operating modes 38 6 720 803 687 (2012/11)