Command Reference Frequency Modulation Subsystem ([:SOURce]) :FM[1]|2[:DEViation]:TRACk Supported PSG-A Series [:SOURce]:FM[1]|2[:DEViation]:TRACk ON|OFF|1|0 [:SOURce]:FM[1]|2[:DEViation]:TRACk? This command enables or disables the deviation coupling between the paths (FM[1] and Fm2). ON (1) This choice will link the deviation value of FM[1] with FM2; FM2 will assume the FM[1] deviation value. For example, if FM[1] deviation is set to 500 Hz and FM2 is set to 2 kHz, enabling the deviation tracking will cause the FM2 deviation value to change to 500 Hz. This applies regardless of the path (FM[1] or FM2) selected in this command OFF (0) This choice disables the coupling and both paths will have independent deviation values. *RST 0 Choices ON Key Entry FM Dev Couple Off On Remarks This command uses exact match tracking, not offset tracking. Chapter 4 OFF 1 0 253