Step 1 2 Check Item Result Is this malfunction code displayed when the function mode Fd-0 (Inch Area) or Fd-2 (Metric Area) is executed? Is the Manual Feed Guide Plate set to the maximum width position? Action • To Step 4. NO • Move the Guide Plate to the NO maximum width position. • Check the Rack Gear. 3 Is the voltage across PJ7AB-14 on PWB-A and GND DC 2.35V or less? YES NO 4 Is the Manual Feed Guide Plate in the minimum width position? • Change PWB-A. • Change the mounting position of VR1. • Change VR1. • Move the Guide Plate to the NO minimum width position. • Check the Rack Gear. 5 Is the voltage across PJ7AB-14 on PWB-A and GND DC 2.35V or more? YES • Change PWB-A. • Change the mounting position NO of VR1. • Change VR1. T-122