Download Datalogic QLM700 Instruction manual
Transcript
TYPICAL LAYOUTS 6.2.2 6 Pass-Through on ID-NET™ An alternative Pass-Through layout allows the more efficient ID-NET™ network to be used. This layout is really an ID-NET Master/Slave Multidata layout which also allows each reader (Master and Slaves) to accept input on the Auxiliary interface, for example to connect a device such as a hand-held reader for manual code reading capability. Each Matrix 210™ transmits its own messages plus any messages received by its Auxiliary interface onto the ID-NET™ interface. The Master passes all messages to the Host. When One Shot or Phase Mode operating mode is used, the reader can be activated by an External Trigger (photoelectric sensor) when the object enters its reading zone. 1 4 Master Slave#2 3 Slave#n 3 3 2 Power 2 Host Main Serial Interface (RS232 or RS485) Auxiliary Serial Interface (RS232) External Trigger (for One Shot or Phase Mode) ID-NET™ Figure 92 – Pass-Through On ID-NET™ Layout The reading device connected to the Host can be connected to a Fieldbus network using a Host Interface module through a CBX500 connection box. NOTE 83