Download Incowin User Manual

Transcript
Repair, Troubleshooting
switching the electronics unit back on until the appropriate LED on
the front of the electronics unit just lights up.
Use the Allen key (accessory) and turn the adjusting screw assigned to the limit switch ( Fig. 10-2) as follows:
Limit switch on the clamping side => clockwise
Limit switch at the measuring shaft end => anticlockwise
503H
Then the maximum measuring length must be redetermined (menu
Settings => Measuring system => Measuring length => Determine).
The measuring head then moves the distance between the two axial limit switches and calculates the maximum mechanical measuring length which the software then saves automatically.
6. Replace the protective plastic cap.
Fig. 10-1V-INCOMETER - protective plastic cap on the end
1
2
3
4
Fig. 10-2: Limit switch axial, arrangement of the adjusting screws
172
1 - adjusting screw for axial limit switch
at the end of the measuring shaft
3 - housing rear panel
2 - adjusting screw for axial limit switch
on the clamping side
4 - connection for probe cable
V-INCOMETER with INCOWIN
ID 10034503