Download MSS Controller/Microstepping Motor Drive User Manual
Transcript
W I R I N G I N P U T S If the sensor output goes low (current flows) at the limit, select the option “Closed.” If the output is open, (or high voltage), choose “Open” (no current flows). Other sensors have sourcing outputs. That means that current can flow out of the sensor output, but not into it. In that case, wire the sensor as shown in Figure 17. MSS – 2200 Ω CW/CCW COM 5-24 Vdc Power + BLU Sourcing BLK Hall Effect CW/CCW LIMIT BRN Figure 17 - PNP “SOURCING” HALL EFFECT CONNECTION If the sensor output goes high (current flows) at the limit, choose the program option “Closed.” If the output is low (open) at the limit, select “Open.” Caution! The current through the MSS limit switch inputs must not exceed 20 mA. Do not use voltages higher than 24 Vdc. 14