Download EpiSensor - KMI Support WIKI
Transcript
DOCUMENT 301929, REVISION B signal return should be connected to the negative input of the analog frontend’s differential or instrumentation amplifier and not to circuit common. The common connection should return to the power supply through only one path. When using a separate mains power supply for the EpiSensor, be very careful that it does not provide a separate ground return through the AC mains ground to the data acquisition computer. Use a star ground configuration for your system with the EpiSensor power supply, data acquisition system and PC all grounded at the same point. In our experience, most noise problems with any installation are normally a result of power grounding or cable shielding! EpiSensor ES-U2 Specifications 42 Type Triaxial force balance accelerometer Dynamic range >145 dB (RMS Noise to RMS Full Scale Clip 0.1 – 20 Hz) Bandwidth DC to 200 Hz Calibration coil Standard Full-scale range User-selectable at ± 0.25g, ± 0.5g, ± 1g, ± 2g or ± 4g Output User-selectable at: ± 2.5V and ± 10V single-ended; ± 5V, ± 20V differential Zero adjust Access hole for simple, efficient adjustment, factory locked option available Linearity < 1000µg /g2 Hysteresis < 0.1% of full scale Cross-axis sensitivity < 1% (including misalignment) Zero point thermal drift < 500µg / 0C Power consumption Quiescent current < 12 mA from ± 12V Mounting Dual bolt for horizontal or vertical mounting Connection Mil Spec Connector Operating temperature -200 to +700 C (00 to 1600 F) EPISENSOR ES-U2 USER GUIDE