PLC Memory and optimization
Joint Use of IEC
and LL984
When using IEC and LL984 jointly, you should harmonize the sizes of both zones
with each other.
By setting the total IEC memory size and Global Data you can automatically
determine the size of the IEC program memory, and also the available space for
LL984-data (user program).
The size of the available memory for LL984 user programs is calculated using the
following formula:
LL984 zone = available LL984 nodes - total IEC memory
When performing this calculation, it must however be ensured that the size of the
LL984 zone is node-oriented and the remaining instructions are kilobyte-oriented.
To set the total IEC memory, select from Project → PLC Configuration → PLC
selection in the IEC Operating System list box, the Enable entry. The IEC zone is
now enabled and you can enter the required memory size in the Total IEC Memory
text box. The memory size is given in kilobytes.
The fixed total IEC memory size is again made up of several zones. You will find the
explanation of how to harmonize these zones vertically in the chapter Harmonizing
the Zones for Global Data and IEC Program Memory (Compact), p. 193.