C12.6.5 C12.6.6 Expansion Tank (a) An expansion tank of suitably capacity for each water circulating system with ballcock, valve, overflow, drain and all necessary accessories shall be provided to meet the local regulations and the operational requirement. (b) The tank shall be fabricated from mild steel plates of 3mm thickness welded onto a mild steel frame. To stiffen the tank, mild steel flat bars are to be intermittently welded on the inside of the tank. (c) All steel work, mild steel angle stand including the surfaces of the tank shall be painted with one coat of best quality primer and two coats of best quality paint. Colour of the tank shall be directed by the Architect or his Representative. Pipework and Valve All pipework shall be R250 copper pipe to BS EN 1057:1996. Jointing method for pipe size 65 mm and above shall be of the flanged brazing or bronze welded type. All pipes shall be properly pitched and supported with strong hangers, brackets and saddles. The support system shall be designed to take into account the size of the pipelines, their content and materials of construction, the vibration isolation components, the amount and direction of movement, the location of the pipeline in relation to the building fabric and other services and the need for access. Adequate provision shall be provided for free expansion and contraction of the pipeline. Gate valves shall be flanged cast iron body with bronze trim, cast iron wedge, bronze rising stem. Globe valves shall be flanged cast iron body, renewable bronze disc and seat, outside screw and bronze rising stem. Disconnecting flanges shall be installed at valves and at suitable locations for cleaning and removal of piping. Where pipes pass through walls or slabs, pipe sleeves shall be provided. Pipes and valves shall be painted in colours with directional arrow indication. C12.6.7 Hydraulic Test (a) Water system and circuits shall be hydraulically tested. (b) Test pressure for water circuits and components shall be 2 times working pressure, or 1.5 working pressure plus 3.5 bar whichever is lower. Section C12 Page 15 of 31 EE_GS 2012 Edition
Related documents
USER MANUAL - Websams Central Document Repository
Design and Applied Technology (Secondary 4 – 6)
Catalog - The Cary Company
Lighting Global Quality Assurance Protocols 3.0 - Global Off
Unión Fenosa
ACGS - HKFEMC
HARDWARE USER`S MANUAL
PACKAGING FILTRATION
USER MANUAL Financial Monitoring and Planning
Dell Venue 8 Pro User`s Manual (3G)
SUNNY ISLAND 8.0H / 6.0H - Installation Manual
Electrical Operational Procedure