Download EEGS - HKFEMC
Transcript
lighting switches per single-gang plate. Lighting switches installed adjacent to a door shall be located on the handle side of the door, and shall be as near to the door as practicable. B4.3.3 Time Switch Time switch shall be housed in a factory or purpose made metal enclosure provided with a removal cover of durable clear plastic material. B4.3.4 Application in Bathroom No switch shall be installed inside a toilet or a room containing a fixed bath or shower. All control switches shall be located immediately outside the room. This restriction does not apply to insulating cord switches, remotely operated switches using mechanical actuators with linkage incorporating insulating components, switched supplied from Separated Extra Low Voltage (SELV) and shaver units. B4.4 INSTALLATION OF SOCKET OUTLETS B4.4.1 General Socket outlet intended for supplying a fixed or stationary appliance shall be located as near as possible to the appliance. Socket outlet shall be mounted at a height of 1350 mm above finished floor level in kitchens, sculleries, ironing rooms and the like. In other locations, they shall be mounted at 300 mm from finished floor level, 75 mm from surface top measured from bottom of socket outlet or as specified. B4.4.2 Shaver Supply Unit The complete unit shall be enclosed in a galvanized metal box for flush mounting, or a galvanized cast iron or plastic surface box for surface mounting. B4.4.3 Socket Outlet at Hazardous Area The installation of socket outlets in hazardous areas should be avoided as far as possible. Where it is absolutely essential to install a socket outlet in such area, the socket outlet shall comply with IEC 60079-0:2007 and other associated parts of the standard and shall be controlled by a sparkless switch. The socket outlet shall be interlocked with the plug so that removal or insertion shall not be possible unless the controlling switch is in the OFF position. The plug shall have shrouded pins and the design of the pin contacts shall Section B4 Page 3 of 4 EE_GS 2012 Edition
Related documents
USER MANUAL - Websams Central Document Repository
Design and Applied Technology (Secondary 4 – 6)
Catalog - The Cary Company
Lighting Global Quality Assurance Protocols 3.0 - Global Off
Unión Fenosa
ACGS - HKFEMC
HARDWARE USER`S MANUAL
PACKAGING FILTRATION
USER MANUAL Financial Monitoring and Planning
Dell Venue 8 Pro User`s Manual (3G)
SUNNY ISLAND 8.0H / 6.0H - Installation Manual
Electrical Operational Procedure