Download Infinitely Expandable MPDP

Transcript
Infinitely Expandable
OPM-4260 | OPM-4260R
4.4. Connection of Control Cable - In case of using the other control program
besides MSCS
※ If you use the other screen control program besides MSCS, the signal cable
must be connected via MFC (Multi- Function Controller) of ORION.
••Control signal transmission can be connected by 2 different methods. (RS-232C or Ethernet)
•• RS-232C and Ethernet connection cannot be used simultaneously.
4.4.2. Connection of Ethernet Cable
••If you want to control MPDP sets with Ethernet, PC and MFC can be connected with Ethernet
cable and between MFC and the first MPDP set and between the other MPDP sets should be
connected with RS-232C cable.
4.4.1. Connection of RS-232C Cable
••The RS-232C signal cable must be connected via MFC.
••Maximum use of RS-232C with Daisy Chain connection is 30 sets or less, if you need additional
connection, use RS-232C distributor.
ID 1
RS-232C
LAN
RS-232C
IN
ID 2
RS-232C
OUT
IN
ID 3
OUT
OUT
ID 5
RS-232C
IN
ID 6
OUT
ID 4
RS-232C
OUT
IN
OUT
ID 5
IN
ID 6
RS-232C
LAN
IN
OUT
IN
IN
ID 8
RS-232C
RS-232C
LAN
OUT
RS-232C
LAN
IN
OUT
IN
RS-232C
RS-232C
IN
OUT
IN
OUT
IN
OUT
LAN Cable
(Cross Cable)
New MFC
HUB or Router
(Wireless & Cable)
Ethernet control PC
RS-232C
New MFC
RS-232C control PC
- 26 -
OUT
ID 9
RS-232C
OUT
ID 9
RS-232C
OUT
RS-232C
IN
ID 8
RS-232C
OUT
LAN
ID 7
OUT
LAN
ID 7
IN
RS-232C
RS-232C
IN
RS-232C
ID 3
LAN
IN
LAN
ID 4
RS-232C
LAN
IN
ID 1
ID 2
LAN Cable
(Direct Cable)
- 27 -
OUT