Concrete-Envelope – User Manual
Program Description
There is a disadvantage to enveloping as opposed to combining load cases. This
disadvantage is that the various stresses at a given location (direct, bending, etc.) are all
enveloped independently and will in general be derived from different constituent cases. It
is unlikely that this worst combination of loads will actually occur simultaneously. In the
concrete checks, however, all components of stress interact to form a single code check
which may therefore result from combinations of stresses which cannot occur at the same
time.
This problem is always present when enveloping load components but is acceptable
because of the considerable saving in cost against code-checking every load combination in
turn. Furthermore, the user always has the option of using CONCRETE-ENVELOPE to
produce simple combinations of load or envelopes of reduced complexity, to recheck areas
which fail the original conservative checks. The enveloping procedure may therefore be
considered to be a first-pass approach used to eliminate locations and regions of the
structure that are not critical. Locations failing these preliminary checks may then be
assessed in more detail. This multi-level checking procedure is generally much more
efficient in time and computer cost.
2.3
LOAD CASE INCLUSION TABLES
At the heart of the CONCRETE-ENVELOPE program are the load case inclusion tables
which define the logic by which individual FE analysis load cases are combined to form
envelopes of load for individual locations in the model.
Each inclusion table generates one envelope of load for each load component, for each
location selected. A number and title for these envelopes may be associated with each table
of inclusion data. For example, for an offshore structure, the following three envelopes may
be generated using three separate inclusion tables:
Envelope 1
Envelope 2
Envelope 3
`Calm Sea'
`Operating Wave'
`Storm Wave'
Each line of an inclusion table contains an instruction which defines how a particular load
case from the FE analysis is to be included in the envelope and provides factors to apply to
this load case for strength and serviceability analysis. Basic load case inclusion table
entries are as follows:
INCL
-
always include this load case whether it extends or reduces the
current envelope;
REVE
-
this load case is reversible. Include it in either direction to extend
both maximum and minimum values;
IFTA
-
include this load case only if it extends the envelope;
CHOO
-
choose a user-specified range of cases from the following list of
cases;
LOAD
-
load case in a CHOO list;
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates.