Download K. Fowler (CRC, 2008) BBS - Web server administration
Transcript
Programmer for Implanted Stimulators 319 TABLE 13.4 Example Portion from a Survey for the Usability of the Programmer User Test Survey—Summary Example Patient Tutorial Questions Yes No Will these instructions be clear to your patient population? Will pressing the buttons be easy for your patients? Do you think the function of the OFF button will be obvious to your patients? Will drawing on the body maps be easy for your patients? Do you think the use of the front and back body maps will be obvious to your patients? Do you think the Right and Left labels on the body maps will be effective with your patients? Will marking the rating scales be easy for your patients? Do you think your patients will be able to adjust the stimulation amplitude easily? Do you think showing this tutorial to your patients will improve their comfort level with neurostimulation? 7 8 4 1 0 4 7 4 1 4 6 2 8 8 0 0 8 0 Average 6.7 1.3 Std. Dev. 1.7 1.7 83% 17% % Agreement Comments Have a way to stop and then resume the tutorial Voice was pleasant Several commented on how well worded it was One physician thought graphics were ‘‘too Mickey Mouse’’ One physician wants branded styluses—one with Alabama, the other with Auburn Patient Tab Questions Yes No Does the Patient Tab provide the basic information you need? Do the buttons on the right side of the Patient Tab make sense to you? Is the Leads information on the Patient Tab clear to you? Does the automated Read Implant function make sense to you? Are you likely to use the Remarks section? 6 1 8 0 8 8 0 0 8 0 Average 7.6 0.2 Std. Dev. 0.9 % Agreement 97% 0.4 3% Comments Undo Changes button was not intuitive Training is a concern. If staff is to use programmer then they must be trained Consider have more information collection: male/female selection, age, diagnosis field (could use Remarks section) with boxes to check like radicularopathy, CRPS, spinal stenosis, and so forth, suggested CPT codes Read Implant button is not intuitive. Use ‘‘Read Serial Number’’ instead or consider ‘‘Read Generator’’ Use ‘‘Exit’’ instead of ‘‘LogOff’’ for button (Continued)
Related documents
Embedded Systems - Chess - Center for Hybrid and Embedded
HIFI Observers` Manual
apply object-oriented programming
Operation Manual-Traffic Measurement
- Owl Security Services
Fluctuat C - User manual
A-7D/E User`s Manual
Thermo PAL User Guide Version C
The “How To” of “How To`s”: Writing Procedures Like a Pro
User Manual For
Woman in Guiyu, China, about to smash the cathode ray tube (CRT
Implementation of an Underwater Digital Acoustic Telemetry Receiver