Download Code 39 Set Length 1 - SC
Transcript
1D Symbologies Enter/Exit Programming Mode Code 39 Set Length 2 This feature specifies one of the bar code lengths for Code 39 Length Control on page 113. Length 2 is the maximum label length if in Variable Length on page 113 Mode, or the second fixed length if in Fixed Length on page 113 Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. Table 4 provides examples for setting Length 2. See page 243 for detailed instructions on setting this feature. Table 4. Code 39 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 2 Scan ENTER/EXIT PROGRAMMING MODE 3 Scan SELECT CODE 39 LENGTH 2 SETTING 4 Scan Two Characters From Appendix D, Keypad 5 Scan ENTER/EXIT PROGRAMMING .MODE 00 (Ignore This Length) ‘0’ and ‘0’ 07 Characters 15 Characters 50 Characters ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’ $CC3L2 Select Code 39 Length 2 Setting Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. ~ CANCEL DEFAULT Product Reference Guide 50 = Length 2 is 50 Characters 115