Download PG-FP5 Flash Memory Programmer User`s Manual

Transcript
PG-FP5
CHAPTER 8 USAGE COMMUNICATION COMMANDS
8.4.14 pwr_off command
Turns off the FP5 power supply.
Input format
'pwr_off' ('now' | 'auto' ('off' | <time [minutes]>))
Description of the function
Turns off the FP5 power supply. Adjusts the off timing by designating the options. If options are not used, then the user
can see if automatic power supply off is enabled or disabled.
now: Turns off the power supply immediately.
auto: After the designated time has elapsed, automatic power supply off is enabled. Once this is designated, even
if the automatic power supply turns off, it will still be enabled if set to ON.
off:
After the designated time has elapsed, automatic power supply off is disabled.
time: Designates the automatic power supply off time. The time can be 1 to 35791394 (in minutes). Note that 1 to
4 are set to 5 minutes.
Example of usage
Command
pwr_off
Screen output
AutoPowerOff is disabled
pwr_off now
PG-FP5 Power will be switched OFF now....
pwr_off auto 10
AutoPowerOff is enabled, time is 10 min.
R20UT0008EJ0500 Rev. 5.00
2011.12.26