Download PG-FP5 Flash Memory Programmer User`s Manual

Transcript
PG-FP5
APPENDIX A MESSAGES
A.4 Error Messages Displayed in FP5 Message Display
(1/3)
No.
001
Message
Invalid PRM data
Error Condition
Possible Workaround
The parameter file may include invalid data, or the file may be
Invalid PRM data
<R>
defective. Perform setting again by using the correct PR5 file.
002
Not connected
005
Not supported!
No device connected to FP5

Issue a ‘con’ command before the command causing this error.
The command issued is not supported on the device and thus
cannot be used.
006
Command aborted!
Command aborted
The [Read] command has been canceled.
008
Parameter Error!
PR5 file Error
The parameter file may be damaged.
011
Read. Sig failed
Device signature reading failed
Check if the correct device is selected.
012
Check connection
Connection check
The FP5 cannot establish connection to the target device.
The cause may be a wrong connection between the device and
the FP5, bad socket contacts or the oscillator not operating.
013
Addr. Range err
Address range error
014
RDY detect. fail
Device does not send RDY signal.
The address given in the command exceeds the device’s
address range.
Wrong connection between device and FP5 or bad socket
contacts.
Setting the Oscillator frequency
Check if the oscillator frequency is allowed. If yes, contact
failed.
Renesas Electronics support desk.
Setting the communication baud
Unsupported baud rate specified. Please consult the device
rate failed.
manual.
ID coe chk. err
ID code does not match.
Set the security ID specified for the target device.
020
Inv. Sig. ID
Invalid signature ID
Check if the correct device is selected.
021
Inv. Sig. Code
Invalid signature code
Check if the correct device is selected.
022
Inv. Sig. func.
Invalid signature function
Check if the correct device is selected.
023
Inv. Sig. addr.
Invalid signature address
Check if the correct device is selected.
024
Inv. device name
Invalid device name
Check if the correct device is selected.
025
Inv. Signature
Invalid signature
Check if the correct device is selected.
026
Inv Dev/Firm ver
Invalid device firmware version
Check if the correct device is selected.
027
Unkn. Signature
Unknown Signature
Check, if the correct PRM file is used.
Inv. DeviceInfo
Invalid device information
Check if the correct device is selected.
Prewrite Timeout
Prewrite timed out
A communication problem occurred between the FP5 and target
015
016
<R> 017
<R> 029
030
Freq. set failed
Baudrt. set fail
device. Try the operation again.
032
Prewrite failed
Prewrite retry error
The device may be damaged.
040
Erase Timeout
Erase timed out
A communication problem occurred between the FP5 and target
041
Erase failure
Erase failed
The device may be damaged.
042
Ers time exceed
Erase timed out
The device may be damaged.
043
Ers Timeset err
Erase time setting error
The PR5 file may contain invalid data. Contact Renesas
device. Try the operation again.
Electronics.
R20UT0008EJ0500 Rev. 5.00
2011.12.26