Download PG-FP5 Flash Memory Programmer User`s Manual
Transcript
PG-FP5 APPENDIX A MESSAGES A.4 Error Messages Displayed in FP5 Message Display (1/3) No. 001 Message Invalid PRM data Error Condition Possible Workaround The parameter file may include invalid data, or the file may be Invalid PRM data <R> defective. Perform setting again by using the correct PR5 file. 002 Not connected 005 Not supported! No device connected to FP5 Issue a ‘con’ command before the command causing this error. The command issued is not supported on the device and thus cannot be used. 006 Command aborted! Command aborted The [Read] command has been canceled. 008 Parameter Error! PR5 file Error The parameter file may be damaged. 011 Read. Sig failed Device signature reading failed Check if the correct device is selected. 012 Check connection Connection check The FP5 cannot establish connection to the target device. The cause may be a wrong connection between the device and the FP5, bad socket contacts or the oscillator not operating. 013 Addr. Range err Address range error 014 RDY detect. fail Device does not send RDY signal. The address given in the command exceeds the device’s address range. Wrong connection between device and FP5 or bad socket contacts. Setting the Oscillator frequency Check if the oscillator frequency is allowed. If yes, contact failed. Renesas Electronics support desk. Setting the communication baud Unsupported baud rate specified. Please consult the device rate failed. manual. ID coe chk. err ID code does not match. Set the security ID specified for the target device. 020 Inv. Sig. ID Invalid signature ID Check if the correct device is selected. 021 Inv. Sig. Code Invalid signature code Check if the correct device is selected. 022 Inv. Sig. func. Invalid signature function Check if the correct device is selected. 023 Inv. Sig. addr. Invalid signature address Check if the correct device is selected. 024 Inv. device name Invalid device name Check if the correct device is selected. 025 Inv. Signature Invalid signature Check if the correct device is selected. 026 Inv Dev/Firm ver Invalid device firmware version Check if the correct device is selected. 027 Unkn. Signature Unknown Signature Check, if the correct PRM file is used. Inv. DeviceInfo Invalid device information Check if the correct device is selected. Prewrite Timeout Prewrite timed out A communication problem occurred between the FP5 and target 015 016 <R> 017 <R> 029 030 Freq. set failed Baudrt. set fail device. Try the operation again. 032 Prewrite failed Prewrite retry error The device may be damaged. 040 Erase Timeout Erase timed out A communication problem occurred between the FP5 and target 041 Erase failure Erase failed The device may be damaged. 042 Ers time exceed Erase timed out The device may be damaged. 043 Ers Timeset err Erase time setting error The PR5 file may contain invalid data. Contact Renesas device. Try the operation again. Electronics. R20UT0008EJ0500 Rev. 5.00 2011.12.26 Page 223 of 254