10.16 Enco DAD™ Automation
[Custom Filter] (continued)
Telling Enco How to Start an Event
The Enco DAD system uses start codes to indicate how an event is to start. These start codes are:
In Enco
q SEGUE
q AUTOLOAD
q AUTOPLAY
q NORMAL
NL8 Log template Event Description
&Segue
&Load
&AutoPlay
&Normal
(See the Enco DAD manual for descriptions). The codes are set in the Natural Log Template Event
Description column as &SEGUE, &LOAD, &AUTOPLAY, and &NORMAL. The default start code assumed
by Natural Log is Segue in the absence of any other code entry.
Once the start code is set, Natural Log continues to send the start code on all subsequent events
until enter another start code in the NL8 Log Templates.
Manual Start Example - Events 0101 and 0103 shown below
You need to load a spot break but wait for a live announcer to start it. This will LOAD the first spot and wait for
the announcer (or satellite network) to start it. Because the &SEGUE is after the first spot in the break, it will
then segue through the break until it hits the End StopSet marker.
Natural Log User Manual
Page 10-51