CONTINUOUS ROD EXTENSOMETER
Protective Cap
Anti Rotation Nut
Securing
Nut
O Ring
Head Tube
To fit the anchor head tube to the grout plate remove the protective cap and securing nut
from the head tube and lubricate the “O” ring with silicon grease.
Insert the threaded section of the head tube through the assigned hole position so that the
thread protrudes through to the side with the stamped positions.
Refit the securing nut and tighten into position using the 22mm socket while holding the
head tube by the anti rotation nut with the 22mm spanner
Do not tighten with excessive force as this may damage the
head tube.
Refit the protective cap.
Assemble the remaining anchors using the same procedure.