SHARKTX & SHARKTXP MULTI-PARAMETER TRANSMITTER USER’S MANUAL Rev 2 AquaMetrix Inc. 1245 Maple Hill Ct., Unit 7 Newmarket, ON Canada, L3Y 9E8 Tel: (800) 742-1413 (905) 954-0841 Fax: (905) 954-0415 www.aquametrix.com MULTI-PARAMETER TRANSMITTER USER’S MANUAL Table of Contents Subject Page No. Introduction 1 Section 1 - Specifications 2 Section 2 - Installation 3-5 Section 3 - Electrical Connections & Setup Differential Probe connection & setup Combination Probe connection & setup Conductivity Cell (Contacting style) connection & setup Paddle Wheel Flow Sensor connection & setup 4-20mA Isolated Output Section 4 - Using the Transmitter in pH Mode LCD Menu Section 5 - Using the Transmitter in ORP Mode LCD Menu Section 6 - Using the Transmitter in Conductivity Mode LCD Menu Section 7 - Using the Transmitter in Flow Mode LCD Menu 6 - 11 7 8 9 10 11 12 13 - 28 29 30 - 44 45 46 - 62 63 64 - 78 Appendix A - Probe Configuration Table 79 Return Policy & Warranty Plan 80 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Introduction The SHARKTX & SHARKTXP multi-parameter transmitter is a microprocessor based transmitter capable of measuring one of the following parameters, pH, ORP, conductivity or flow. When shipped from the factory, the Shark is not set to measure any one parameter. When the Shark is powered up for the first time, it will display the meter selection screen where the meter type must be selected. (refer to section 4.5 Meter Selection) This meter selection screen will only be displayed when the Shark is powered up for the first time. After the user selects a meter type the Shark will remain set to that meter type until it is changed with the meter selection menu function in the Utilities menu. To return the Shark to its factory settings, the user must re-select the current meter type from the meter selection menu function. This will override all set-points and return all settings back to the factory settings. The Shark Users menu has been divided into five main categories - Calibration, used to calibrate the Shark with the selected sensor Utilities, used to manually control or override the outputs. Setup, used to configure the Sharks many options Diagnostics, used to troubleshoot problems with the Shark or sensor Outputs, used to configure the Shark’s 4 to 20mA output. SHARKTX is packaged in a rugged NEMA 4X polycarbonate enclosure with a universal mounting kit for surface, panel and pipe-mount applications. This enclosure is perfect for stand-alone or panel-mount operation. SHARKTXP enclosure is also polycarbonate with a NEMA 4X front panel. Panel mount, and DIN rail mounting hardware are supplied. Introduction Page 1 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Section I - Specifications Display Power Requirements Measuring Range Temperature Compensation Temperature Unit Temperature Sensor Calibration Modes Ambient Conditions Sensor to Transmitter Distance Analog Output Memory Back-up Mechanical Sensor Input Invalid Entries Manual Test Mode Output Hold Calibration Data Auto Return Display Damping Net Weight Approvals pH ORP 2 x 16 alpha-numeric LCD display 4 to 20mA, Loop Powered, 16 to 32 VDC Conductivity Flow Flow: 0 to 9999 with selectable flow rate units pH: 0.01 to 14.00 ORP: -1999 to +1999mV Volume: 0 - 999 with Auto Range (Dependent on sensor) Flow rate units: Gallons (GP), Cubic Temp: 0 to 100°C or Temp: 0 to 100°C or Feet (CF), Liters (LP), Cubic Meters 32° to +212°F 32° to +212°F (CM), custom by entering factor related to Gallons Time units: Seconds (S), Minutes (M) Temp: 0 to 100°C or 32° to +212°F Hours (H) Automatic or Manual Automatic or Manual User selectable temperature Not required Not required 0 - 100°C (32° to +212°F) compensation slope 0.0 to 10.0%/°C. 0 to 100°C (32° to +212°F) °C or °F Not required User selectable: 300Ω NTC Thermistor, 3000Ω NTC Thermistor or Pt. 1000 RTD Not required Auto-Calibration Dry Calibration Manual Calibration Manual Calibration Sample Calibration K factor Input Temperature Calibration Temperature Calibration Temperature Calibration Temperature: -20°C to +60°C or -4°F to +140°F Humidity: 0 to 90% RH (non-condensing) Differential Sensor: 3000 ft 300 ft 2000 ft Combination Sensor: 10 ft 4 to 20mA Isolated Output, Range expand 0 to 100% of full scale (min segment 10% of full scale), max. load 800Ω All user settings are retained indefinitely in memory (EEPROM) SHARKTX Enclosure: NEMA 4X, 1/4 DIN, polycarbonate enclosure with two 1/2” conduit holes SHARKTXP Enclosure: NEMA 4X front panel, 1/4 DIN, polycarbonate SHARKTX Mounting: Universal Mounting kit for surface, pipe and panel mount included SHARKTXP Mounting: Panel and DIN rail mount included Probe: -600 to +600mV Probe: -1999 to +1999mV Cell: 0 to 9999Ω Paddle: 0 to 2000Hz Temp. Sensor: 0 to 9999Ω Temp. Sensor: 0 to 9999Ω Temp. Sensor: 0 to 9999Ω Invalid entries cannot be stored Process value can be simulated with arrow keys to verify correct setup of output 4 to 20mA output is placed on hold when the transmitter is in Menu mode Recall data from last Recall data from last calibration, calibration mode, calibration, calibration buffer 1st & 2nd accepted buffer value and probe mV output, accepted value, and cell Recall store K factor. calibration temperature, calibration slope, and probe resistance, calibration efficiency temperature User selectable auto return if the transmitter is left in menu mode for more than 10 min. User can select rate at which the transmitter updates display. Enables display damping of unstable process SHARKTX: 0.71 lbs (0.32 kg) SHARKTXP: 0.25 lbs (0.12 kg) ULC (pending) Section I - Specifications MΩ/cm3 0 to 19.99 0 to 2.000 0 to 20.00 uS/cm3 0 to 200.0 0 to 5000 0 to 20.00 mS/cm3 0 to 200.0 0.01 0.01 0.1 0.1 1.0 10 50 Page 2 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Section 2 - Installation 2.1 Unpacking Save the shipping carton and packing material in case the instrument needs to be stored or returned. Inspect the instrument and packing material for shipping damage and report any problems immediately. 2.2 Location Locate the transmitter close to the sensor. The list below gives typical maximum distances for various sensors. Refer to the sensor specifications for exact information. • • • • Aquametrix Aquametrix Aquametrix Aquametrix Differential PH Probe Combination PH Probe Conductivity Probe Flow sensor 3000 ft (914 meters) 10 ft (3 meters) 300 ft (91 meters) 2000 ft (610 meters) 2.3 Mounting Fig 2.1 SHARKTX Transmitter dimensions Dwg# N106-128 Section 2 - Installation Page 3 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Section 2 - Installation Fig 2.2 SHARKTXP Transmitter dimensions Dwg# N106-129 Panel Mount – The transmitters can be panel mounted to a panel using the hardware kit provided. The panel cutout dimensions are shown in fig. 2.1 and 2.2. Figure 2.3 Panel Mount EXTERNAL PANEL GASKET QTY.1 PANEL (CUSTOMER SUPPLIED) UNIVERSAL MOUNTIN G BRACKET QTY.1 SCREW 10-24 X 1/2" QTY.4 UNIVERSAL MOUNTING CLAMP QTY.2 SCREW 1/4-20 X 2-1/2" QTY.4 EXTERNAL PANEL GASKET QTY.1 PANEL (CUSTOMER SUPPLIED) SCREW 4-40 X 3/4" QTY.4 NUT 4-40 QTY.4 NUT 1/4-20 QTY.4 Dwg# N105-101 & N105-104 Section 2 - Installation Page 4 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Section 2 - Installation Surface Mount – The SHARKTX can be surface mounted using the hardware kit provided with the unit. Figure 2.4 Surface Mount UNIVERSAL MOUN TING BRACKET QTY.1 Pipe Mount – The SHARKTX can be mounted to a horizontal or vertical pipe with: SCREW 10-24 X 1/2" QTY.4 • a minimum outside diameter of 1.30” (33mm) (for example 1” CPVC pipe) • and a maximum of 2.375” (60mm) (for example 2” CPVC pipe) HOLES Ø1/4" FOR MOUNTING SCREWS QTY.4 (CUSTOMER SUPPLIED) DIN Rail Mount – The SHARKTXP can be DIN rail mounted or panel mounted. See figure 2.3 & figure 2.7. Dwg# N105-101 Figure 2.6 Horizontal Pipe Mount Fig. 2.5 Vertical Pipe Mount MIN. PIPE DIA. 1" PIPE (NOMINAL) MAX. PIPE DIA. 2" PIPE (NOMINAL) MIN. PIPE DIA. 1" PIPE (NOMINAL) MAX. PIPE DIA. 2" PIPE (NOMINAL) UNIVERSAL MOUNTING BRACKET QTY.1 NUT 10-24 QTY.4 NUT 10-24 QTY.4 SCREW 10-24 X 3-1/2" QTY.4 Dwg# N105-101 Dwg# N105-101 SCREW 10-24 X 3-1/2" QTY.4 UNIVERSAL MOUNTING BRACKET QTY.1 Figure 2.7 DIN Rail Mount TS35 DIN RAIL MOUNT (CUSTOMER SUPPLIED) TS32 DIN RAIL MOUNT (CUSTOMER SUPPLIED) Dwg# N105-104 Section 2 - Installation Page 5 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Section 3 - Electrical Connections and Setup 3.1 Conduit Connections The SHARKTX has two 1/2” conduit holes at the bottom of the enclosure as shown on fig. 2.1. The unit is shipped with these holes plugged with liquid tight conduit seals. These must be left in unused holes to maintain the NEMA 4X integrity. Use approved conduit hubs to connect the conduit, connect these to the conduit before connecting to the enclosure. 3.2 Power Connections Figure 3.1 Connections Dwg# N104-41 Section 3 - Electrical Connections and Setup Page 6 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Section 3 - Electrical Connections and Setup 3.3 pH and ORP Differential Probe connections and setup The drawing shows the connections for the Aquametrix Differential (5 wire) probe. The cable should be run in a conduit separate from AC power wires, and via a separate conduit hole. Figure 3.2 Connections for Differential (5 wire) pH or ORP probe Dwg# N104-42 Once connected, step through the LCD menus to select the probe in the order shown. The first two steps may be skipped if the meter is already configured for pH or ORP and a Differential Probe. When using a pH probe, it is important to ensure that the transmitter is reading the probe temperature correctly for accurate temperature compensation. The ORP probe does not require temperature compensation, although the transmitter can display process temperature measured by the probe. The factory temperature calibration is usually accurate enough that no adjustments are necessary. Section 3 - Electrical Connections and Setup METER SELECTION SELECT pH SEC. 4.6 or ORP SEC. 5.5 (IF NECESSARY) PROBE SELECT SELECT DIFFERENTIAL PROBE pH SEC. 4.7 or ORP SEC. 5.6 (IF NECESSARY) MANUAL CAL PH MANUAL CALIBRATE pH PROBE SEC. 4.1 or ORP PROBE SEC. 5.1 7.15pH 25.0C RUN MODE Page 7 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Section 3 - Electrical Connections and Setup 3.4 pH or ORP Combination Probe connections and setup The drawing shows the connections for the Aquametrix Combination probe. The cable should be run in a conduit separate from AC power wires, and via a separate conduit hole. The cable length should not exceed 10 feet (3 meters). The 2 wire version has no temperature sensor and is connected via a coaxial wire. In a pH meter, the user should set the T COMP OVERRIDE menu to ON (Section 4.10) and adjust the temperature setting to the actual probe temperature. In an ORP meter, the user should set the T.DISP OVERRIDE to ON (Section 5.9) to blank the temperature reading on the display. Fig. 3.3 Connections for the 2 and 4 wire Combination Probe The 4 wire version has two additional wires for the probe internal temperature sensor. Ensure that the T COMP OVERRIDE or T.DISP OVERRIDE is OFF. Dwg# N104-43 Once connected, step through the LCD menus to select the probe in the order shown. The first two steps may be skipped if the meter is already configured for a Combination Probe. If a two wire pH probe is used, which has no temperature sensor, ensure that the Temp. Comp. Override is set to same temperature as the buffer before calibrating. If a two wire ORP probe is used, you can blank the Temp display with the T DISP OVERRIDE menu. pH ORP METER SELECTION SELECT PH METER SEC. 4.6 METER SELECTION SELECT ORP METER SEC. 5.5 PROBE SELECT SELECT COMBINATION PROBE SEC. 4.7 PROBE SELECT SELECT COMBINATION PROBE SEC. 5.8 TWO WIRE PROBE WITH NO TEMP SENSOR MANUAL CAL PH 7.15pH 25.0C MANUAL CALIBRATE PH PROBE SEC. 4.1 RUN MODE TWO WIRE PROBE WITH NO TEMP SENSOR T.COMP OVERRIDE MANUAL PROBE TEMPERATURE SETUP SEC 4.10 Section 3 - Electrical Connections and Setup MANUAL CAL PH 7.15pH 25.0C MANUAL CALIBRATE ORP PROBE SEC. 5.1 RUN MODE T.DISP OVERRIDE DISABLE TEMPERATURE DISPLAY SEC 5.10 Page 8 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Section 3 - Electrical Connections and Setup 3.5 Conductivity Cell (Contacting style) connections and setup The drawing shows the connections for the Aquametrix Conductivity Cells (Contacting style). The cable should be run in a conduit seperate from the AC power wires, and via a seperate conduit hole. The cell cable length should not exceed 300ft. (91 meters). Figure 3.4 Connections for Conductivity Cells Dwg# N104-44 Once connnected, step through the LCD menus to select the cell in the order shown. The TEMP COMP CURVE setup default is 1.8%/deg C. This is acceptable for most process applications. If your process is significantly different from this, change the setting in the TEMP COMP CURVE menu. METER SELECTION SELECT COND METER SEC. 6.6 COND RANGE SELECT CONDUCTIVITY RANGE SEC. 6.7 TEMP SENSOR ENSURE SENSOR IS CORRECT TYPE 3Kohm NTC (thermistor) 1Kohm RTD SEC 6.9 TEMP COMP CURVE SET TEMPERATURE COMPENSATION FOR PROCESS SEC. 6.13 OR MANUAL CAL COND CALIBRATE WITH REFERENCE SOLUTIONS SEC 6.1 1000uS RUN MODE Section 3 - Electrical Connections and Setup 25.0C DRY CAL COND CALIBRATE WITH FACTORY SPECIFIED CELL CONSTANT SEC 6.2 Page 9 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Section 3 - Electrical Connections and Setup 3.6 Paddle Wheel Flow Sensor connections and setup The drawing shows the connnections for a typical paddle wheel flow sensor. The cable to the sensor should not exceed 2000’ (600 meters). Figure 3.5 Connections for Flow Sensor Dwg# N104-45 Once connected, step through the LCD menus to select the sensor in the order shown. The Sensor K factor (pulses per U.S. Gallon) is usually printed on the side of the sensor or on a label attached to the sensor cable. Section 3 - Electrical Connections and Setup METER SELECTION SELECT FLOW METER SEC. 7.4 ENTER FLOW SENSOR CALIBRATION FACTOR SEC. 7.1 K FACTOR UNITS OF VOLUME SETUP OF UNITS OF VOLUME SEC 7.5 UNITS OF TIME SETUP OF UNITS OF TIME SEC. 7.6 TOTALIZER RESET RESET TOTALIZER TO ZERO SEC 7.0 TOTAL RUN MODE 0 Page 10 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Section 3 - Electrical Connections and Setup 3.10 MANUAL TEST MODE (LCD MENU SECTIONS - pH: 4.4, ORP: 5.3, Conductivity: 6.4, Flow: 7.2) The setup can be tested using Manual Test Mode to simulate process changes. MANUAL TEST MODE is used to simulate a process reading in order to verify the correct response of the output. 3.11 4-20 mA Isolated Output (LCD MENU SECTIONS - pH: 4.15, ORP: 5.14, Conductivity: 6.16, Flow: 7.14) The Transmitter has a single 4 to 20mA output, electrically isolated from the ground. The output can source current into a resistive load. Maximum resistance depends on supply voltage. Drawing on page 6 (Fig. 3.1) The output is dedicated to track the process and has fully independent and fully adjustable 4 & 20 mA output setpoints. This will enable the operator to span the output over the desired range. The output can be precisely trimmed through the LCD menu for precision applications. The drawing on page 6 (Fig. 3.1) shows the connections for the output. Wire Specification: 22 AWG 7/30, insulation 0.010” Section 3 - Electrical Connections and Setup Page 11 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Section 4 - Using the Transmitter in pH Mode 1/4" TURN SCREWS (FOR SHARKTX ONLY) 2 LINE, 16 CHARACTER LCD DISPLAY MAIN MENU INTERFACE SCREEN UNIT LABEL LABEL TO INDICATE UNIT OF MEASURE SHARK IS CONFIGURED FOR. SIMPLE THREE-BUTTON INTERFACE FOR FAST & EASY SETUP (REFER TO SECTIONS 4.0 TO 4.15) Section 4 - Using the Transmitter in pH Mode Page 12 MULTI-PARAMETER TRANSMITTER USER’S MANUAL pH - Menu Overview 4.0 RUN MODE 7.15pH 25.0C DOWN CALIBRATION DOWN MANUAL CAL pH UTILITIES DOWN DOWN AUTO CAL pH SETUP DOWN DOWN TEMP CALIBRATION DIAGNOSTICS DOWN DOWN MANUAL CALIBRATE pH PROBE SEC. 4.1 AUTO CALIBRATE pH PROBE SEC. 4.2 CALIBRATE TEMP. SENSOR IN pH PROBE SEC. 4.3 EXIT OUTPUT DOWN DOWN EXIT DOWN PROBE SELECT DOWN TEMP UNIT MANUAL TEST MODE SELECT TYPE OF pH PROBE SEC. 4.6 SELECT DEG C OR DEG F SEC 4.7 DOWN METER SELECTION DOWN DOWN TEMP SENSOR DOWN AUTO RETURN DOWN T.COMP OVERRIDE DOWN DISPLAY DAMPING DOWN SIMULATE PROCESS VERIFY OUTPUTS SEC. 4.4 SELECT TYPE OF METER SEC. 4.5 EXIT SELECT TYPE OF TEMP SENSOR SEC 4.8 DOWN ENABLE TIME OUT FROM MENU SEC. 4.9 TEMPERATURE SETUP FOR PROBE WITHOUT TEMP. SENSOR SEC 4.10 SETUP DISPLAY AND OUTPUT RESPONSE TIME SEC 4.11 EXIT DOWN FIRMWARE REV DOWN CALIBRATION DATA DOWN SENSOR INPUT DOWN DISPLAY FIRMWAVE REVISION SEC. 4.12 DISPLAY PREVIOUS CALIBRATION DATA SEC 4.13 DISPLAY UNCALIBRATED PROBE DATA SEC 4.14 EXIT DOWN 4-20mA DOWN SETUP 4-20 mA OUTPUT SEC 4.15 EXIT DOWN pH - Menu Overview 4.0 NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Page 13 MULTI-PARAMETER TRANSMITTER USER’S MANUAL pH - Calibration Menu - Manual Calibrate 4.1 7.15pH 25.0C RUN MODE DOWN CALIBRATION MANUAL CAL pH Place the probe in the first buffer solution, be sure to clean and rinse the Probe first with D.I. water and then insert it in the 7.00 buffer. IF BUFFER1 READY PRESS 'DOWN' Press DOWN RUNNING MANU CAL BUFFER1 WAIT... MANUAL CAL pH BUFFER1 UP 7.3 5 > DOWN MANUAL CAL pH BUFFER1 7.0 0 > MANUAL CAL pH BUFFER1 7.00 > DOWN This example shows a MANUAL calibration with buffers of 7pH & 4pH. Please wait for the controller to complete the measurement When complete, the controller will report the measured value Use the UP and DOWN keys to adjust the reading until it agrees with the actual buffer pH value Then press to move the cursor to the RH position Then press DOWN to store the value and move to BUFFER2 Place the probe in the second buffer. Be sure to clean and rinse the Probe first with D.I. water and then insert it in the 4.00 buffer. IF BUFFER2 READY PRESS 'DOWN' When performing a manual calibration, any two known buffer solutions can be used. DOWN The controller will read the pH value, averaging a number of results to get a stable calibration value. Press DOWN DOWN RUNNING MANU CAL BUFFER2 WAIT... MANUAL CAL pH BUFFER2 UP 4.4 0 > DOWN MANUAL CAL pH BUFFER2 4.0 0 > MANUAL CAL pH BUFFER2 4.00 > DOWN The controller will read the pH value, averaging a number of results to get a stable calibration value. Please wait for the controller to complete the measurement When complete, the controller will report the measured value Use the UP and DOWN keys to adjust the reading until it agrees with the actual buffer pH value Then press to move the cursor to the RH position Then press DOWN to store the value and complete the Manual Calibration After 5 seconds, the controller will compute the slope of the calibration, the estimated probe efficiency and the probe temperature. SLOPE 61.22MV/pH EFF 95% 24.8C If the calibration is OK, use the key to move the cursor over the Y text and press the down key. If the calibration did not appear to be correct, press the DOWN key which will return back to the Manual Cal menu. MANUAL CAL pH STORE? DOWN Y N MANUAL CAL pH STORE? Y N DOWN Press DOWN to store the calibration data and return back to the Manual Cal menu so the user can select another function. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE pH - Calibration Menu - Manual Calibrate 4.1 Page 14 MULTI-PARAMETER TRANSMITTER USER’S MANUAL pH - Calibration Menu - Auto Calibrate 4.2 7.15pH 25.0C RUN MODE DOWN CALIBRATION MANUAL CAL pH DOWN AUTO CAL pH Place the probe in the first buffer solution, be sure to clean and rinse the Probe first with D.I. water and then insert it in the 7.00 buffer. IF BUFFER1 READY PRESS 'DOWN' DOWN Press RUNNING AUTO CAL BUFFER1 WAIT... If an erros occurs, the controller will indicate a "BUFFER ERROR" alarm. This could be caused by - using a defective buffer - incorrect probe wiring - defective probe BUFFER ERROR CONTINUE Press to return to the Auto cal menu, try to correct the problem and calibrate again, or go to the diagnotics menus to test the probe see Section 4.16 AUTO CAL pH BUFFER1 This example shows an AUTO calibration with buffers of 7pH & 4pH. When performing an auto calibration, any two standard buffers of 4.00, 7.00 or 10.00 pH can be used. The buffers will be automatically recognized if the probe measures them within +/- 1 pH of their nominal value. DOWN The controller will read the pH value, averaging a number of results to get a stable calibration value. Please wait for the controller to complete the measurement 7.00 > When complete, the controller will report the measured value Press the DOWN > DOWN key to move to Buffer 2 Place the probe in the second buffer solution.Be sure to clean and rinse the Probe first with D.I. water and then insert it in the 4.00 buffer. Press the DOWN key IF BUFFER2 READY PRESS 'DOWN' DOWN The controller will read the pH value, averaging a number of results to get a stable calibration value. RUNNING AUTO CAL BUFFER2 WAIT... Please wait for the controller to complete the measurement If an erros occurs, the controller will indicate a "BUFFER ERROR" alarm. This could be caused by - using the same buffer twice - using a defective buffer - incorrect probe wiring - defective probe BUFFER ERROR CONTINUE Press to return to the Auto cal menu, try to correct the problem and calibrate again, or go to the diagnotics menus to test the probe AUTO CAL pH BUFFER2 4.00 > > When complete, the controller will report the measured value DOWN After 5 seconds, the controller will compute the slope of the calibration, the estimated probe efficiency and the probe temperature. SLOPE 61.22MV/pH EFF 95% 24.8C If the calibration is OK, use the key to move the cursor over the Y text and press the down key. If the calibration did not appear to be correct, press the DOWN key which will return back to the Auto cal menu. AUTO CAL pH STORE? DOWN Y N AUTO CAL pH STORE? DOWN Y N This will store the calibration data and return back to the Auto cal setup so the user can select another function. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE pH - Calibration Menu - Auto Calibrate 4.2 Page 15 MULTI-PARAMETER TRANSMITTER USER’S MANUAL pH - Calibration Menu - Temperature Calibration 4.3 7.15pH 25.0C RUN MODE DOWN CALIBRATION MANUAL CAL pH If the Temperature Compensation Override is set to ON (see section 4.11), the Shark cannot calibrate the temperature sensor. This display will appear to alert the user to the condition. DOWN AUTO CAL pH DOWN TEMP CALIBRATION TEMP CALIBRATION TEMP O/R ON > DOWN The controller displays the current probe temperature. If this incorrect, the controller can be adjusted to compensate. TEMP CALIBRATION 22.4C > DOWN TEMP CALIBRATION 22. 4 C UP Press the key once which will move the cursor over the least sign. digit of the temperature display. > Use the UP and DOWN to adjust the reading until it agrees with the known temperature of the probe DOWN TEMP CALIBRATION 25. 0 C > TEMP CALIBRATION 25.0C > Press the key once which will move the cursor back to the RH side of temperature display. Press the DOWN key to accept the reading and move to the store function DOWN T FACTOR SHIFTED If the calibration does not appear to be correct, press the DOWN key which will return back to the Temp Calibration menu. TEMP CALIBRATION STORE? Y N DOWN "T FACTOR SHIFTED" will be displayed for 5 seconds to indicate that the temperature sensor has been calibrated. The Shark will then move to the store function. TEMP CALIBRATION STORE? Y N DOWN This will store the calibration data and return back to the Temp Calibration setup so the user can select another function. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE pH - Calibration Menu - Temperature Calibration 4.3 Page 16 MULTI-PARAMETER TRANSMITTER USER’S MANUAL pH - Utilities Menu - Manual Test Mode 4.4 7.15pH 25.0C Manual Test Mode is used to simulate a process reading in order to verify the correct response of the output. When in the Manual Test Mode, the output IS no longer placed on hold as it is when in the rest of the menu. RUN MODE DOWN CALIBRATION DOWN UTILITIES MANUAL TEST MODE TEST 7.00 > 12.0mA Press the key once which will move the cursor over the least digit of the simulated process value. DOWN TEST 7.0 0 > 12.0mA UP Use the UP and DOWN keys to change the simulated process value. DOWN TEST 13.1 5 > 19.0mA The 4 to 20 mA output will follow the process value change. The 4-20 mA output will track the change in process value TEST 13.1 5 > 19.0mA TEST 13.15 > 19.0mA Press the key once to move the cursor to the RH side of the display Press the DOWN key to return to the MANUAL TEST MODE menu DOWN NOTE: When the user exits the Manual Test Mode, the 4-20mA output will remain in the Test Mode state until the operator enters the run mode. The output will then revert back to the previous On-line state. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE pH - Utilities Menu - Manual Test Mode 4.4 Page 17 MULTI-PARAMETER TRANSMITTER USER’S MANUAL pH - Utilities Menu - Meter Selection 4.5 7.15pH 25.0C RUN MODE The Meter Selection menu is used to select the meter type that the controller is configured for, either pH, ORP, Conductivity or FLow. Once selected, the controller will initialize itself for the selected meter's functionality and move to run mode. DOWN CALIBRATION DOWN UTILITIES MANUAL TEST MODE Press the key to initialize the controller as a pH meter. DOWN METER SELECTION PH ORP PH INITIALIZE? DOWN Y N DOWN Press the key to initialize the controller as an ORP meter ORP INITIALIZE? O RP CONDUCTIVITY DOWN To reset the controller back to all the factory default values, reselect the current meter type Y N DOWN Press the key to initialize the controller as a Conductivity meter CONDUCTIVITY INITIALIZE? C ONDUCTIVITY FLOW DOWN Y N DOWN Press the key to initialize the controller as a Flow meter FLOW INITIALIZE? F LOW EXIT DOWN Y N DOWN Press the key to Exit and return to the Utilities menu E XIT PH If you do not wish to initialize to this type of meter after all, then press DOWN key to return back to the Meter Selection menu DOWN If you do wish to initialize to this type of meter, press the key to highlight the Y character Then press DOWN The controller will initialize itself for a specific meter PH INITIALIZE? Y N DOWN NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE pH - Utilities Menu - Meter Selection 4.5 Page 18 MULTI-PARAMETER TRANSMITTER USER’S MANUAL pH - Setup Menu - Probe Select 4.6 7.15pH 25.0C RUN MODE DOWN CALIBRATION DOWN PROBE SELECT will allow the user to select whether the probe is a 2 or 4 wire combination probe, or a 5 wire differential probe. UTILITIES DOWN SETUP PROBE SELECT PROBE SELECT DIFFERENTIAL > DOWN Use the UP or DOWN keys to scroll through the probe types available. In this case, the user can select - the 2 or 4 wire combination probe - the 5 wire differential probe PROBE SELECT D IFFERENTIAL Note: If using the 2 wire Combination Probe (which doesn't have a temperature sensor), T COMP OVERRIDE must be set to ON, and the actual probe temperature set through the T COMP OVERRIDE menu. (see sec. 4.11) UP DOWN Once the correct probe type is selected, move to the store function to save the selection PROBE SELECT C OMBINATION Press the key once which will move the cursor back to the RH side of the display. PROBE SELECT COMBINATION > DOWN With "N" selected, pressing the DOWN key will NOT store the selection, but simply return to the PROBE SELECT PROBE SELECT Menu. This function is useful if you STORE? wish to view the current selection without making any changes. Not stored Press the key once which will move the cursor over the first character of the probe type. Or press the the Y character. Y N Press the DOWN key to accept the setting and move to the store function key to highlight PROBE SELECT STORE? Y N DOWN Stored Then press the DOWN key to store the selection and return to the PROBE SELECT Menu. Note: Refer to Appendix A - Probe Configuration Table NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE pH - Setup Menu - Probe Select 4.6 Page 19 MULTI-PARAMETER TRANSMITTER USER’S MANUAL pH - Setup Menu -Temp Unit 4.7 7.15pH 25.0C RUN MODE TEMP UNIT allows the user to select either Degrees Centigrade or Fahrenheit units for display DOWN CALIBRATION DOWN UTILITIES DOWN SETUP PROBE SELECT DOWN TEMP UNIT TEMP UNIT DEGREE C > TEMP UNIT DEGREE C UP Press the key once which will move the cursor over the unit type, C or F. > Use the DOWN TEMP UNIT DEGREE F > TEMP UNIT DEGREE F > DOWN or UP Y N to select C or F Press the key once which will move the cursor back to the RH side of the display. Press the DOWN key to accept the change and move to the store function Or press the the Y character. With "N" selected, pressing the DOWN TEMP UNIT key will NOT store the selection, but STORE? simply return to the TEMP UNIT DOWN Selection Menu. This function is useful if you wish to view the current selection Not stored without making any changes. DOWN key to highlight TEMP UNIT STORE? Y N DOWN Stored Then press the DOWN key to store the selection and return to the TEMP UNIT Selection Menu. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE pH - Setup Menu - Temp Unit 4.7 Page 20 MULTI-PARAMETER TRANSMITTER USER’S MANUAL pH - Setup Menu - Temp. Sensor 4.8 7.15pH 25.0C RUN MODE TEMP SENSOR allows the user to select the type of temperature sensor used the in the probe. DOWN CALIBRATION The factory default for pH is a 300 Ω NTC Thermistor. The user can also select a 3000 Ω NTC Thermistor or a 1000 RTD. DOWN UTILITIES DOWN SETUP PROBE SELECT DOWN TEMP UNIT TEMP SENSOR TEMP SENSOR 300 Ω NTC > Press the key once which will move the cursor over to the sensor type. Use the UP sensor type TEMP SENSOR 3 00 Ω NTC UP > DOWN TEMP SENSOR 1 000 Ω RTD UP or DOWN to select the Once the correct Sensor has been selected press the key once which will move the cursor back to the RH side of the display. > DOWN TEMP SENSOR 3 000 Ω NTC > TEMP SENSOR 300 Ω NTC > DOWN Press the DOWN key to accept the change and move to the store function Or press the the Y character. TEMP SENSOR With "N" selected, pressing the DOWN STORE? key will NOT store the selection, but DOWN simply return to the TEMP SENSOR Selection Menu. This function is useful if you wish to view the current selection Not stored without making any changes. Y N key to highlight TEMP SENSOR STORE? Y N DOWN Stored Then press the DOWN key to store the selection and return to the TEMP SENSOR Selection Menu. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE pH - Setup Menu - Temp. Sensor 4.8 Page 21 MULTI-PARAMETER TRANSMITTER USER’S MANUAL pH - Setup Menu - Auto Return 4.9 7.15pH 25.0C RUN MODE AUTO RETURN is used to select what conditions will cause the controller to time-out of the operations menu DOWN CALIBRATION DOWN UTILITIES DOWN SETUP MENU ON will cause the controller to exit the menu and revert back to the online run mode after 10 minutes with no buttons pressed. This feature ensures that if a user forgets to return back to run mode, the controller will not be left in an offline state. If for some reason, the user would like to remain in the menu mode for extended periods of time, the AUTO RETURN function can be set to "OFF". PROBE SELECTION DOWN TEMP UNIT DOWN TEMP SENSOR DOWN AUTO RETURN AUTO RETURN MENU ON To change the MENU RETURN setting, Press the key once which will move the cursor to the ON or OFF text > DOWN AUTO RETURN MENU O N UP > AUTO RETURN MENU O FF > AUTO RETURN MENU OFF > Or press the the Y character. AUTO RETURN STORE? DOWN Not stored Y N AUTO RETURN STORE? DOWN Stored Press the key once which will move the cursor back to the RH side of the display. Press the DOWN key to accept the change and move to the STORE function DOWN With "N" selected, pressing the DOWN key will NOT store the selection, but simply return to the AUTO RETURN Selection Menu. This function is useful if you wish to view the current selection without making any changes. Use the UP or DOWN keys to select either ON or OFF. DOWN key to highlight Y N Then press the DOWN key to store the selection and return to the Auto Return Selection Menu. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE pH - Setup Menu - Auto Return 4.9 Page 22 MULTI-PARAMETER TRANSMITTER USER’S MANUAL pH - Setup Menu - T.Comp Override 4.10 7.15pH 25.0C RUN MODE Temperature Compensation Override is used to manually set the actual probe or process temperature. This is useful if the probe does not have a temperature sensor or if the process temperature is constant. When the override is enabled, the controller will use the selected temperature when performing temperature compensation calculations. DOWN CALIBRATION DOWN UTILITIES DOWN SETUP PROBE SELECTION DOWN TEMP UNIT DOWN TEMP SENSOR DOWN AUTO RETURN Press the key once which will move the cursor to the ON or OFF text DOWN T.COMP OVERRIDE T.COMP OVERRIDE COMPENSATE OFF > DOWN T.COMP OVERRIDE COMPENSATE O FF > UP Use the UP or DOWN keys to select either ON or OFF. DOWN T.COMP OVERRIDE COMPENSATE O N > T.COMP OVERRIDE COMPENSATE O N > Press the key once which will move the cursor back to the RH side of the display. DOWN Press the DOWN key to accept the change and move to the Temperature Entry function The user can now enter the actual probe or process temperature T.COMP OVERRIDE TEMP 25.4C Press the key once which will move the cursor over the least significant digit of the temperature display. > DOWN T.COMP OVERRIDE TEMP 25. 4 C UP > Use the UP and DOWN to adjust the reading until it agrees with the known temperature of the probe or process DOWN NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Press the key once which will move the cursor back to the RH side of temperature display. T.COMP OVERRIDE TEMP 35. 7 C > T.COMP OVERRIDE TEMP 35.7C > DOWN Press the DOWN key to accept the reading and move to the store function If you wish to save the setting, press the key to highlight the Y character With "N" selected, pressing the DOWN key will NOT store the selection, but simply return to the T. Comp Override Menu. This function is useful if you wish to view the current selection without making any changes. T.COMP OVERRIDE STORE? Y N DOWN Not stored pH - Setup Menu - T.Comp Override 4.10 T.COMP OVERRIDE STORE? Y N DOWN Stored Then press the DOWN key to store the selection and return to the T. COMP OVERRIDE Menu. Page 23 MULTI-PARAMETER TRANSMITTER USER’S MANUAL pH - Setup Menu - Display Damping 4.11 7.15pH 25.0C RUN MODE DOWN CALIBRATION DOWN UTILITIES The Display Damping menu allows the user to adjust the rate at which the display and the output is updated. This allows the user to dampen out unstable process readings. The damping can be set from 0 seconds to 10 seconds. (default value is 0 sec.) DOWN SETUP PROBE SELECTION DOWN TEMP UNIT DOWN TEMP SENSOR DOWN AUTO RETURN DOWN T.COMP OVERRIDE Press the key once which will move the cursor over the seconds digit DOWN DISPLAY DAMPING DISPLAY DAMPING UPDATE 0SEC > DOWN DISPLAY DAMPING UPDATE 0 SEC UP > DOWN Use the UP and DOWN to adjust the damping time, the default setting is 0 seconds. The setting can be adjusted from 0 to 10 seconds. Press the key once which will move the cursor back to the RH side of the display. DISPLAY DAMPING UPDATE 1 0 SEC > DISPLAY DAMPING UPDATE 10 SEC > Press the DOWN key to accept the setting and move to the store function DOWN With "N" selected, pressing the DOWN DISPLAY DAMPING key will NOT store the selection, but STORE? Y N simply return to the Display Damping DOWN Menu. This function is useful if you wish to view the current selection without making any changes. If you wish to save the setting, press the key to highlight the Y character DISPLAY DAMPING STORE? Y N DOWN Not stored Stored Then press the DOWN key to store the selection and return to the Display Damping Menu. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE pH - Setup Menu - Display Damping 4.11 Page 24 MULTI-PARAMETER TRANSMITTER USER’S MANUAL pH - Diagnostics Menu - Firmware Rev 4.12 7.15pH 25.0C RUN MODE DOWN CALIBRATION The FIRMWARE REV menu allows the user to see what revision of the firmware is currently installed in the controller. This is a Read Only menu item. DOWN UTILITIES DOWN SETUP DOWN DIAGNOSTICS FIRMWARE REV. FIRMWARE REV. 1.00 DOWN pH - Diagnostics Menu - Firmware Rev 4.12 NOTE > PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Page 25 MULTI-PARAMETER TRANSMITTER USER’S MANUAL pH - Diagnostics Menu - Calibration Data 4.13 7.15pH 25.0C RUN MODE The Calibration Data menu is a series of read only screens which allow the user to view the data collected during the last calibration. DOWN CALIBRATION DOWN UTILITIES DOWN SETUP DOWN DIAGNOSTICS FIRMWARE REV. DOWN CALIBRATION DATA Press to view the first Calibration Data screen. CALIBRATION DATA MODE 2PT > Press DOWN to view the next Calibration Data screen. DOWN CALIBRATION DATA 1P 7.00/ -19 Calibration Mode 2 point calibration > 1st POINT PH = 7.00 INPUT FROM PROBE = - 19 mV > 2nd POINT PH = 4.00 INPUT FROM PROBE = + 143 mV > Probe Temperature at which calibration was performed = 19.4°C > Calculated slope based on 2 point calibration = 59.16 mV/pH > Calculated efficiency based on 2 point calibration = 91 % DOWN CALIBRATION DATA 2P 4.00/ 143 DOWN CALIBRATION DATA CAL TEMP 19.4C DOWN CAL SLOPE 59.16MV/PH DOWN CAL EFFICIENCY EFF 91% DOWN NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE pH - Diagnostics Menu - Calibration Data 4.13 Page 26 MULTI-PARAMETER TRANSMITTER USER’S MANUAL pH - Diagnostics Menu - Sensor Input 4.14 7.15pH 25.0C RUN MODE DOWN CALIBRATION DOWN The Sensor Input Menu allows the user to view real time, uncompensated process data from the probe. This is a Read only menu item. UTILITIES DOWN SETUP DOWN DIAGNOSTICS FIRMWARE REV. DOWN CALIBRATION DATA DOWN SENSOR INPUT Press to view the Sensor Input data. PROBE -18mV TEMP 331Ω The top line shows the mV input from the probe The bottom line shows the actual value of the temperature sensor in ohms. > DOWN NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Troubleshooting a pH probe using the sensor input Sensor input displays the uncompensated sensor input data. The pH probe values are displayed in mV (millivolts). The temperature sensor value is displayed in Ω (ohm). Connect the pH probe as per Probe Configuration Table in Appendix A. 1. Place the probe in buffer 7pH (allow temperature to stabilize) • Probe should read 0mV [±50mV] • Temperature should read 300Ω [±50Ω] @ 25°C • Record both of these numbers. 2. Place the probe in buffer 4pH • Probe should read +160mV more than probe value at 7pH • Temperature should read the same as in 7pH 3. Place the probe in buffer 10pH • Probe should read -160mV less then probe value at 7pH • Temperature should read the same as in 7pH pH - Diagnostics Menu - Sensor Input 4.14 Page 27 MULTI-PARAMETER TRANSMITTER USER’S MANUAL pH - Output Menu - 4-20mA Output 4.15 RUN MODE 7.15pH 25.0C The Transmitter has a single 4-20mA output, electrically isolated from the ground. The output can source current into a maximum of 800 ohms. See Section 3.9 for wiring diagram. The channel has a fully adjustable 4 & 20 mA output adjustments. This will enable the operator to span the output over the desired range. DOWN CALIBRATION DOWN UTILITIES DOWN SETUP DOWN DIAGNOSTICS The example below shows the 4-20 mA set to 4mA =7.00pH and 20mA = 14pH. The output would then span 4 to 20 mA for a pH swing of 7.0 to 14.0. Note that the span can reversed, in that 4 mA can be set to a high pH value, and 20 mA can be set to a low pH value, effectively reversing the control direction. DOWN OUTPUT 4-20mA If you wish to change the setting, press the key once which will move the cursor to the first character of the value to be changed 4-20mA PROC 4mA OUT 0.00 > DOWN 4-20mA PROC 4mA OUT 0.0 0 UP NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE > DOWN 4-20mA PROC 4mA OUT 7.0 0 > 4-20mA PROC 4mA OUT 7.00 > If you wish to change the setting, press the key once which will move the cursor to the first character of the value to be changed > 4-20mA PROC STORE? Not stored DOWN Stored 4-20mA PROC 20mA OUT 14.0 0 UP The TUNE value can be adjusted over the range from 0 to 1000, these are unitless numbers used for tuning purposes only. With "N" selected, pressing the DOWN key will NOT store the selection, but simply return to the OUTPUT Menu. This function is useful if you wish to view the current selection without making any changes. DOWN > DOWN 4-20mA PROC 20mA OUT 14.0 0 > 4-20mA PROC 20mA OUT 14.00 > Use the UP and DOWN keys to change the setting Press the key once which will move the cursor back to the RH side of the display. Press the DOWN key to accept the setting and move to the next setting DOWN If you wish to change the setting, press the key once which will move the cursor to the first character of the value to be changed 4-20mA PROC 20mA TUNE 512 DOWN Y N Or press the key to highlight the Y character > 4-20mA PROC 20mA TUNE 51 2 UP > DOWN 4-20mA PROC 20mA TUNE 54 0 > 4-20mA PROC 20mA TUNE 54 0 > DOWN 4-20mA PROC STORE? Press the key once which will move the cursor back to the RH side of the display. Press the DOWN key to accept the setting and move to the next setting DOWN The TUNE fuction allows the user to precisely adjust the 4-20 ma output to compensate for any errors in the output circuitry. Normally, fine tuning the 4-20mA output is not 4-20mA PROC necessary. 20mA OUT 14.00 To make the adjustment, place an accurate DOWN current meter in series with the 4-20 mA output, with the appropriate loads connected. When the TUNE menu is selected, the controller puts 20 mA out the terminals. Use the UP or DOWN keys to adjust the 20mA output to get exactly 20. Use the UP and DOWN keys to change the setting Use the UP and DOWN keys to change the setting Press the key once which will move the cursor back to the RH side of the display. Press the DOWN key to accept the setting and move to the next setting Y N Then press the DOWN key to store the selection and return to the OUTPUT menu pH - Output Menu - 4-20mA Output 4.15 Page 28 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Section 5 - Using the Transmitter in ORP Mode 1/4" TURN SCREWS (FOR SHARKTX ONLY) 2 LINE, 16 CHARACTER LCD DISPLAY MAIN MENU INTERFACE SCREEN UNIT LABEL LABEL TO INDICATE UNIT OF MEASURE SHARK IS CONFIGURED FOR. SIMPLE THREE-BUTTON INTERFACE FOR FAST & EASY SETUP (REFER TO SECTIONS 5.0 TO 5.13) Section 5 - Using the Transmitter in ORP Mode Page 29 MULTI-PARAMETER TRANSMITTER USER’S MANUAL ORP - Menu Overview 5.0 RUN MODE 500mV 25.0C DOWN CALIBRATION DOWN MANUAL CALIBRATE ORP PROBE SEC. 5.1 MANUAL CAL ORP UTILITIES DOWN DOWN TEMP CALIBRATION DOWN EXIT SETUP DOWN DIAGNOSTICS CALIBRATE TEMP. SENSOR IN ORP PROBE SEC. 5.2 DOWN DOWN OUTPUT DOWN MANUAL TEST MODE EXIT DOWN DOWN PROBE SELECT DOWN TEMP UNIT SELECT TYPE OF ORP PROBE SEC. 5.5 SELECT DEG C OR DEG F SEC 5.6 DOWN AUTO RETURN DOWN T. DISP OVERRIDE DOWN DISPLAY DAMPING DOWN SELECT TYPE OF METER SEC. 5.4 METER SELECTION DOWN EXIT DOWN DOWN TEMP SENSOR SIMULATE PROCESS VERIFY OUTPUTS SEC. 5.3 SELECT TYPE OF TEMP SENSOR SEC. 5.7 ENABLE TIME OUT FROM MENU SEC. 5.8 DISABLE TEMPERATURE DISPLAY ON LCD AND LED DISPLAYS SEC 5.9 SETUP DISPLAY AND OUTPUT RESPONSE TIME SEC 5.10 EXIT DOWN FIRMWARE REV DOWN CALIBRATION DATA DOWN SENSOR INPUT DOWN DISPLAY FIRMWAVE REVISION SEC. 5.11 DISPLAY PREVIOUS CALIBRATION DATA SEC 5.12 DISPLAY UNCALIBRATED PROBE DATA SEC 5.13 EXIT DOWN 4-20mA DOWN SETUP 4-20 mA OUTPUT SEC 5.14 EXIT NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE DOWN ORP - Menu Overview 5.0 Page 30 MULTI-PARAMETER TRANSMITTER USER’S MANUAL ORP - Calibration Menu - Manual Calibrate 5.1 500mV 25.0C RUN MODE DOWN CALIBRATION MANUAL CAL ORP Place the probe in the buffer solution, be sure to clean and rinse the Probe first with D.I. water and then insert it in the mV buffer. IF BUFFER READY PRESS ©DOWN© Press DOWN DOWN The controller will read the mV value, averaging a number of results to get a stable calibration value. RUNNING MANU CAL BUFFER WAIT... Please wait for the controller to complete the measurement MANUAL CAL ORP BUFFER 50 0 UP > DOWN Use the UP and DOWN keys to adjust the reading until it agrees with the actual buffer mV value MANUAL CAL ORP BUFFER 60 0 > MANUAL CAL ORP BUFFER 600 > DOWN BUFFER 600mV TEMP 25.0C When complete, the controller will report the measured value Then press to move the cursor to the RH position The controller will display the mV value and the probe temperature for 5 seconds. If the T.DISPLAY O/R is enabled, the display will show. TEMP O/R ON If the calibration is OK, use the key to move the cursor over the Y text and press the down key. If the calibration did not appear to be correct, press the DOWN key which will return back to the Manual Cal menu. MANUAL CAL ORP STORE? Y N DOWN MANUAL CAL ORP STORE? Y N DOWN Press DOWN to store the calibration data and return back to the Manual Cal menu so the user can select another function. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE ORP - Calibration Menu - Manual Calibrate 5.1 Page 31 MULTI-PARAMETER TRANSMITTER USER’S MANUAL ORP - Calibration Menu - Temp. Calibration 5.2 500mV 25.0C RUN MODE If the Temperature Display Override is set to ON (see section 5.10), the Shark cannot calibrate the temperature sensor. This display will appear to alert the user to the condition. DOWN CALIBRATION MANUAL CAL ORP DOWN TEMP CALIBRATION TEMP CALIBRATION TEMP O/R ON > DOWN The controller displays the current probe temperature. If this incorrect, the controller can be adjusted to compensate. TEMP CALIBRATION 22.4C > DOWN TEMP CALIBRATION 22. 4 C UP Press the key once which will move the cursor over the least sign. digit of the temperature display. > Use the UP and DOWN to adjust the reading until it agrees with the known temperature of the probe DOWN TEMP CALIBRATION 25. 0 C > TEMP CALIBRATION 25.0C > Press the key once which will move the cursor back to the RH side of temperature display. Press the DOWN key to accept the reading and move to the store function DOWN T FACTOR SHIFTED If the calibration did not appear to be correct, press the DOWN key which will return back to the Temp Calibration menu. TEMP CALIBRATION STORE? Y N DOWN "T FACTOR SHIFTED" will be displayed for 5 seconds to indicate that the temperature sensor has been calibrated. The Shark will then move to the store function. TEMP CALIBRATION STORE? Y N DOWN This will store the calibration data and return back to the Temp Calibration setup so the user can select another function. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE ORP - Calibration Menu - Temp. Calibration 5.2 Page 32 MULTI-PARAMETER TRANSMITTER USER’S MANUAL ORP - Utilities Menu - Manual Test Mode 5.3 500mV 25.0C Manual Test Mode is used to simulate a process reading in order to verify the correct response of the output. When in the Manual Test Mode, the outputs is no longer placed on hold as it is when in the rest of the menu. RUN MODE DOWN The range is 0 to +1000mV. CALIBRATION DOWN UTILITIES MANUAL TEST MODE TEST 500 > 12.0mA Press the key once which will move the cursor over the least digit of the simulated process value. DOWN TEST 50 0 > 12.0mA UP Use the UP and DOWN keys to change the simulated process value. DOWN TEST 80 0 > 16.8mA The 4-20 mA output will follow the process value change. The 4-20 mA output will track the change in process value TEST 50 0 > 12.0mA TEST 500 > 12.0mA Press the key once to move the cursor to the RH side of the display Press the DOWN key to return to the MANUAL TEST MODE menu DOWN NOTE: When the user exits the Manual Test Mode, the 4-20mA output will remain in the Test Mode state until the operator enters the run mode. The output will then revert back to the previous On-line state. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE ORP - Utilities Menu - Manual Test Mode 5.3 Page 33 MULTI-PARAMETER TRANSMITTER USER’S MANUAL ORP - Utilities Menu - Meter Selection 5.4 500mV 25.0C The Meter Selection menu is used to select the meter type that the controller is configured for, either pH, ORP, Conductivity or FLow. Once selected, the controller will initialize itself for the selected meter's functionality and move to run mode. RUN MODE DOWN CALIBRATION DOWN UTILITIES MANUAL TEST MODE Press the key to initialize the controller as a pH meter. DOWN METER SELECTION PH ORP PH INITIALIZE? DOWN Y N DOWN Press the key to initialize the controller as an ORP meter O RP CONDUCTIVITY ORP INITIALIZE? DOWN To reset the controller back to all the factory default values, reselect the current meter type Y N DOWN Press the key to initialize the controller as a Conductivity meter C ONDUCTIVITY FLOW CONDUCTIVITY INITIALIZE? DOWN Y N DOWN Press the key to initialize the controller as a Flow meter F LOW EXIT FLOW INITIALIZE? DOWN Y N DOWN Press the key to Exit and return to the Utilities menu E XIT PH If you do not wish to initialize to this type of meter after all, then press DOWN key to return back to the Meter Selection menu DOWN If you do wish to initialize to this type of meter, press the key to highlight the Y character Then press DOWN The controller will initialize itself for a specific meter ORP INITIALIZE? Y N DOWN NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE ORP - Utilities Menu - Meter Selection 5.4 Page 34 MULTI-PARAMETER TRANSMITTER USER’S MANUAL ORP - Setup Menu - Probe Select 5.5 500mV 25.0C RUN MODE DOWN CALIBRATION DOWN PROBE SELECT will allow the user to select whether the probe is a 2 or 4 wire combination probe, or a 5 wire differential probe. UTILITIES DOWN SETUP PROBE SELECT PROBE SELECT DIFFERENTIAL > DOWN Use the UP or DOWN keys to scroll through the probe styles available. In this case, the user can select - the 2 or 4 wire combination probe - the 5 wire differential probe PROBE SELECT D IFFERENTIAL Note: If using the 2 wire Combination Probe (which doesn't have a temperature sensor), T DISP OVERRIDE must be set to ON, and the actual probe temperature set through the T DISP OVERRIDE menu. (see sec. 5.10) UP DOWN Once the correct style probe is selected, move to the store function to save the selection PROBE SELECT C OMBINATION Press the key once which will move the cursor back to the RH side of the display. PROBE SELECT COMBINATION > DOWN With "N" selected, pressing the DOWN key will NOT store the selection, but simply return to the PROBE SELECT PROBE SELECT Menu. This function is useful if you STORE? wish to view the current selection without making any changes. Not stored Press the key once which will move the cursor over the first character of the probe type. Or press the the Y character. Y N Press the DOWN key to accept the setting and move to the store function key to highlight PROBE SELECT STORE? Y N DOWN Stored Then press the DOWN key to store the selection and return to the PROBE SELECT Menu. Note: Refer to Appendix A - Probe Configuration Table NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE ORP - Setup Menu - Probe Select 5.5 Page 35 MULTI-PARAMETER TRANSMITTER USER’S MANUAL ORP - Setup Menu - Temp. Unit 5.6 500mV 25.0C RUN MODE TEMP UNIT allows the user to select either Degrees Centigrade or Fahrenheit units for display DOWN CALIBRATION DOWN UTILITIES DOWN SETUP PROBE SELECT DOWN TEMP UNIT TEMP UNIT DEGREE C > TEMP UNIT DEGREE C UP Press the key once which will move the cursor over the unit type, C or F. > Use the DOWN TEMP UNIT DEGREE F > TEMP UNIT DEGREE F > DOWN or UP Y N to select C or F Press the key once which will move the cursor back to the RH side of the display. Press the DOWN key to accept the change and move to the store function Or press the the Y character. With "N" selected, pressing the DOWN TEMP UNIT key will NOT store the selection, but STORE? simply return to the TEMP UNIT DOWN Selection Menu. This function is useful if you wish to view the current selection Not stored without making any changes. DOWN key to highlight TEMP UNIT STORE? Y N DOWN Stored Then press the DOWN key to store the selection and return to the TEMP UNIT Selection Menu. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE ORP - Setup Menu - Temp. Unit 5.6 Page 36 MULTI-PARAMETER TRANSMITTER USER’S MANUAL ORP - Setup Menu - Temp. Sensor 5.7 500mV 25.0C RUN MODE TEMP SENSOR allows the user to select the type of temperature sensor used in the probe. DOWN CALIBRATION The factory default for ORP is a 300 NTC Thermistor. The user can also select a 3000 NTC Thermistor or a 1000 RTD. DOWN UTILITIES DOWN SETUP PROBE SELECT DOWN TEMP UNIT TEMP SENSOR TEMP SENSOR 300 NTC > Press the key once which will move the cursor over to the sensor type. Use the UP sensor type TEMP SENSOR 3 00 Ω NTC UP > DOWN TEMP SENSOR 1 000 Ω RTD UP or DOWN to select the Once the correct Sensor has been selected press the key once which will move the cursor back to the RH side of the display. > DOWN TEMP SENSOR 3 000 Ω NTC > TEMP SENSOR 300 NTC > DOWN Press the DOWN key to accept the change and move to the store function Or press the the Y character. TEMP SENSOR With "N" selected, pressing the DOWN STORE? key will NOT store the selection, but DOWN simply return to the TEMP SENSOR Selection Menu. This function is useful if you wish to view the current selection Not stored without making any changes. Y N key to highlight TEMP SENSOR STORE? Y N DOWN Stored Then press the DOWN key to store the selection and return to the TEMP SENSOR Selection Menu. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE ORP - Setup Menu - Temp. Sensor 5.7 Page 37 MULTI-PARAMETER TRANSMITTER USER’S MANUAL ORP - Setup Menu - Auto Return 5.8 500mV 25.0C RUN MODE DOWN AUTO RETURN is used to select what conditions will cause the controller to time-out of the operations menu CALIBRATION DOWN UTILITIES DOWN SETUP MENU ON will cause the controller to exit the menu and revert back to the online run mode after 10 minutes with no buttons pressed. This feature ensures that if a user forgets to return back to run mode, the controller will not be left in an offline state. If for some reason, the user would like to remain in the menu mode for extended periods of time, the AUTO RETURN function can be set to "OFF". PROBE SELECTION DOWN TEMP UNIT DOWN TEMP SENSOR DOWN AUTO RETURN AUTO RETURN MENU ON To change the MENU RETURN setting, Press the key once which will move the cursor to the ON or OFF text > DOWN AUTO RETURN MENU O N UP > DOWN AUTO RETURN MENU O FF > AUTO RETURN MENU OFF > With "N" selected, pressing the DOWN key will NOT store the selection, but simply return to the AUTO RETURN Selection Menu. This function is useful if you wish to view the current selection without making any changes. AUTO RETURN STORE? DOWN Not stored Y N AUTO RETURN STORE? DOWN Stored Press the key once which will move the cursor back to the RH side of the display. Press the DOWN key to accept the change and move to the STORE function DOWN Or press the the Y character. Use the UP or DOWN keys to select either ON or OFF. key to highlight Y N Then press the DOWN key to store the selection and return to the Auto Return Selection Menu. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE ORP - Setup Menu - Auto Return 5.8 Page 38 MULTI-PARAMETER TRANSMITTER USER’S MANUAL ORP - Setup Menu - Temp. Display Override 5.9 500mV 25.0C RUN MODE T. Display Override is used to blank the Temperature Display on the LCD menu and place 4 dots on the LED menu when Temp display is requested.This is to ensure the user isn't shown a temperature value that isn't valid. DOWN CALIBRATION DOWN UTILITIES DOWN SETUP PROBE SELECTION DOWN TEMP UNIT DOWN TEMP SENSOR DOWN AUTO RETURN Press the key once which will move the cursor to the ON or OFF text DOWN T. DISP OVERRIDE T. DISP OVERRIDE OVERRIDE OFF > DOWN T. DISP OVERRIDE OVERRIDE O FF UP > DOWN T. DISP OVERRIDE OVERRIDE ON > T. DISP OVERRIDE OVERRIDE ON > Use the UP or DOWN keys to select either ON or OFF. Press the key once which will move the cursor back to the RH side of the display. Press the DOWN key to accept the change and move to the store function DOWN If you wish to save the setting, press the key to highlight the Y character With "N" selected, pressing the DOWN key will NOT store the selection, but simply return to the T. Disp. Override Menu. This function is useful if you wish to view the current selection without making any changes. T.COMP OVERRIDE STORE? Y N DOWN Not stored T.COMP OVERRIDE STORE? Y N DOWN Stored Then press the DOWN key to store the selection and return to the T. DISP OVERRIDE Menu. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE ORP - Setup Menu - Temp. Display Override 5.9 Page 39 MULTI-PARAMETER TRANSMITTER USER’S MANUAL ORP - Setup Menu - Display Damping 5.10 500mV 25.0C RUN MODE DOWN CALIBRATION DOWN UTILITIES The Display Damping menu allows the user to adjust the rate at which the display and the output is updated. This allows the user to dampen out unstable process readings. The damping can be set from 0 seconds to 10 seconds. (default value is 0 sec.) DOWN SETUP PROBE SELECTION DOWN TEMP UNIT DOWN TEMP SENSOR DOWN AUTO RETURN DOWN T. DISP OVERRIDE Press the key once which will move the cursor over the seconds digit DOWN DISPLAY DAMPING DISPLAY DAMPING UPDATE 0SEC > DOWN DISPLAY DAMPING UPDATE 0 SEC UP > DOWN Use the UP and DOWN to adjust the damping time, the default setting is 0 seconds. The setting can be adjusted from 0 to 10 seconds. Press the key once which will move the cursor back to the RH side of the display. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE DISPLAY DAMPING UPDATE 1 0 SEC > DISPLAY DAMPING UPDATE 10 SEC > Press the DOWN key to accept the setting and move to the store function DOWN With "N" selected, pressing the DOWN DISPLAY DAMPING key will NOT store the selection, but STORE? Y N simply return to the Display Damping DOWN Menu. This function is useful if you wish to view the current selection without making any changes. If you wish to save the setting, press the key to highlight the Y character DISPLAY DAMPING STORE? Y N DOWN Not stored ORP - Setup Menu - Display Damping 5.10 Stored Then press the DOWN key to store the selection and return to the Display Damping Menu. Page 40 MULTI-PARAMETER TRANSMITTER USER’S MANUAL ORP - Diagnostics Menu - Firmware Rev 5.11 500mV 25.0C RUN MODE DOWN CALIBRATION The FIRMWARE REV menu allows the user to see what revision of the firmware is currently installed in the controller. This is a Read Only menu item. DOWN UTILITIES DOWN SETUP DOWN DIAGNOSTICS FIRMWARE REV. FIRMWARE REV. 1.00 DOWN ORP - Diagnostics Menu - Firmware Rev 5.11 NOTE > PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Page 41 MULTI-PARAMETER TRANSMITTER USER’S MANUAL ORP - Diagnostics Menu - Calibration Data 5.12 500mV 25.0C RUN MODE The Calibration Data menu is a series of read only screens which allow the user to view the data collected during the last calibration. DOWN CALIBRATION DOWN UTILITIES DOWN SETUP DOWN DIAGNOSTICS FIRMWARE REV. DOWN CALIBRATION DATA Press to view the first Calibration Data screen. CALIBRATION DATA MODE 1PT > Press DOWN to view the next Calibration Data screen. DOWN CALIBRATION DATA 600mV Calibration Mode 1 point calibration 1st POINT 600mV > DOWN CALIBRATION DATA CAL TEMP 19.4C > Probe Temperature at which calibration was performed = 19.4 C DOWN If the Temperature Display Override is ON (Section 5.10), the display will show CALIBRATION DATA TEMP O/R ON NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE ORP - Diagnostics Menu - Calibration Data 5.12 Page 42 MULTI-PARAMETER TRANSMITTER USER’S MANUAL ORP - Diagnostics Menu - Sensor Input 5.13 500mV 25.0C RUN MODE DOWN CALIBRATION DOWN The Sensor Input Menu allows the user to view real time, uncompensated process data from the probe. This is a Read only menu item. UTILITIES DOWN SETUP DOWN DIAGNOSTICS FIRMWARE REV. DOWN CALIBRATION DATA DOWN SENSOR INPUT Press to view the Sensor Input data. PROBE 500mV TEMP 331Ω > The top line shows the mV input from the probe The bottom line shows the actual value of the temperature sensor in ohms. DOWN If the Probe is not equiped with a Temperature Sensing Device, and Temperature Display Override is ON (Section 5.10), the display will show NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE PROBE 500mV TEMP O/R ON ORP - Diagnostics Menu - Sensor Input 5.13 Page 43 MULTI-PARAMETER TRANSMITTER USER’S MANUAL ORP - Output Menu - 4-20mA Output 5.14 RUN MODE 500mV 25.0C The Transmitter has a single 4-20mA output, electrically isolated from the ground. The output can source current into a maximum of 800 ohms. See Section 3.9 for wiring diagram. The channel has a fully adjustable 4 & 20 mA output adjustments. This will enable the operator to span the output over the desired range. DOWN CALIBRATION DOWN UTILITIES DOWN SETUP DOWN DIAGNOSTICS The example below shows the 4-20 mA set to 4mA =200mV and 20mA = 800mV. The output would then span 4 to 20 mA for a mV swing of 200mV to 800mV. Note that the span can be reversed, in that 4 mA can be set to a high mV value, and 20 mA can be set to a low mV value, effectively reversing the control direction. DOWN 4-20mA OUTPUT If you wish to change the setting, press the key once which will move the cursor to the first character of the value to be changed 4-20mA PROC 4mA OUT 0.00 > DOWN 4-20mA PROC 4mA OUT 0 UP NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE > DOWN 4-20mA PROC 4mA OUT 20 0 > 4-20mA PROC 4mA OUT 200 > If you wish to change the setting, press the key once which will move the cursor to the first character of the value to be changed > 4-20mA PROC STORE? Not stored DOWN Stored 4-20mA PROC 20mA OUT 100 0 UP The TUNE value can be adjusted over the range from 0 to 1000, these are unitless numbers used for tuning purposes only. With "N" selected, pressing the DOWN key will NOT store the selection, but simply return to the OUTPUT Menu. This function is useful if you wish to view the current selection without making any changes. DOWN > DOWN 4-20mA PROC 20mA OUT 80 0 > 4-20mA PROC 20mA OUT 800 > Use the UP and DOWN keys to change the setting Press the key once which will move the cursor back to the RH side of the display. Press the DOWN key to accept the setting and move to the next setting DOWN If you wish to change the setting, press the key once which will move the cursor to the first character of the value to be changed 4-20mA PROC 20mA TUNE 512 DOWN Y N Or press the key to highlight the Y character > 4-20mA PROC 20mA TUNE 51 2 UP > DOWN 4-20mA PROC 20mA TUNE 54 0 > 4-20mA PROC 20mA TUNE 54 0 > DOWN 4-20mA PROC STORE? Press the key once which will move the cursor back to the RH side of the display. Press the DOWN key to accept the setting and move to the next setting DOWN The TUNE fuction allows the user to precisely adjust the 4-20 ma output to compensate for any errors in the output circuitry. Normally, fine tuning the 4-20mA output is not 4-20mA PROC necessary. 20mA OUT 1000 To make the adjustment, place an accurate DOWN current meter in series with the 4-20 mA output, with the appropriate loads connected. When the TUNE menu is selected, the controller puts 20 mA out the terminals. Use the UP or DOWN keys to adjust the 20mA output to get exactly 20. Use the UP and DOWN keys to change the setting Use the UP and DOWN keys to change the setting Press the key once which will move the cursor back to the RH side of the display. Press the DOWN key to accept the setting and move to the next setting Y N Then press the DOWN key to store the selection and return to the OUTPUT menu ORP - Output Menu - 4-20mA Output 5.14 Page 44 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Section 6 - Using the Transmitter in Conductivity Mode 1/4" TURN SCREWS (FOR SHARKTX ONLY) 2 LINE, 16 CHARACTER LCD DISPLAY MAIN MENU INTERFACE SCREEN UNIT LABEL LABEL TO INDICATE UNIT OF MEASURE SHARK IS CONFIGURED FOR. SIMPLE THREE-BUTTON INTERFACE FOR FAST & EASY SETUP (REFER TO SECTIONS 6.0 TO 6.16) Section 6 - Using the Transmitter in Conductivity Mode Page 45 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Conductivity - Menu Overview 6.0 RUN MODE 1000uS 25.0C DOWN CALIBRATION DOWN MANUAL CAL COND UTILITIES DOWN DOWN DRY CAL COND DOWN TEMP CALIBRATION SETUP DOWN DIAGNOSTICS DOWN DOWN CALIBRATE PROBE WITH BUFFER SOL'N SEC. 6.1 CALIBRATE PROBE WITH MANUFACTURER'S DATA SEC. 6.2 CALIBRATE TEMP. SENSOR IN PROBE SEC. 6.3 EXIT OUTPUT DOWN DOWN EXIT COND. RANGE DOWN DOWN TEMP UNIT SELECT MEASURING RANGE SEC. 6.6 MANUAL TEST MODE SELECT DEG C OR DEG F SEC 6.7 METER SELECTION DOWN DOWN TEMP SENSOR DOWN AUTO RETURN DOWN T.COMP OVERRIDE DOWN DISPLAY DAMPING DOWN TEMP COMP CURVE DOWN SELECT TYPE OF METER SEC. 6.5 DOWN SELECT TYPE OF TEMP SENSOR SEC 6.8 ENABLE TIME OUT FROM MENU SEC. 6.9 SIMULATE PROCESS VERIFY OUTPUTS SEC. 6.4 EXIT DOWN TEMPERATURE SETUP FOR PROBE WITHOUT TEMP. SENSOR SEC 6.10 SETUP DISPLAY AND OUTPUT RESPONSE TIME SEC 6.11 SETUP TEMP COMPENSATION VALUE SEC 6.12 EXIT DOWN FIRMWARE REV DOWN CALIBRATION DATA DOWN SENSOR INPUT DOWN DISPLAY FIRMWAVE REVISION SEC. 6.13 DISPLAY PREVIOUS CALIBRATION DATA SEC 6.14 DISPLAY UNCALIBRATED PROBE DATA SEC 6.15 EXIT DOWN 4-20mA DOWN SETUP 4-20 mA OUTPUT SEC 6.16 EXIT NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE DOWN Conductivity - Menu Overview 6.0 Page 46 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Conductivity - Calibration Menu - Manual Calibrate 6.1 Manual Calibration is used to "wet calibrate the cell". This can be done with the cell installed in the process, or with the cell suspended in a known buffer solution. When calibrated "In Process", the actual conductivity is determined with a grab sample or a hand held meter, and the value entered in the display. When calibrated with buffers, the cell is placed in a known buffer solution, and the value of the buffer entered on the display. In both cases, make sure the cell has time to stabilize both in temperature and conductivity before entering any data. 1000uS 25.0C Place the cell in the buffer solution The controller will read the Conductivity value, averaging a number of results to get a stable calibration value. RUN MODE DOWN CALIBRATION MANUAL CAL COND MANUAL CAL COND 967 uS > Press the key once which will move the cursor over the least sign. digit of the display. MANUAL CAL COND 96 7 uS > Use the UP and DOWN keys to adjust the reading until it agrees with the actual buffer conductivity value MANUAL CAL COND 100 0 uS > Then press to move the cursor to the RH position MANUAL CAL COND 1000 uS > UP DOWN If the calibration is OK, use the key to move the cursor over the Y text and press the down key. If the calibration did not appear to be correct, press the DOWN key which will return back to the Manual Cal Cond menu. MANUAL CAL COND STORE? Y N DOWN MANUAL CAL COND STORE? Y N DOWN Press DOWN to store the calibration data and return back to the Manual Cal Cond menu so the user can select another function. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Conductivity - Calibration Menu - Manual Calibrate 6.1 Page 47 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Conductivity - Calibration Menu - Dry Cal Cond 6.2 1000uS 25.0C Dry Calibration eliminates the need for conductivity reference solutions, the user inputs the Cell K factor supplied by the factory. RUN MODE DOWN CALIBRATION MANUAL CAL COND If the conductivity cell has a tag attached to it, specifying the exact cell constant, the user is prompted to enter this value. DOWN DRY CAL COND NOTE: ACCELERATOR KEYS Pressing the UP or DOWN key once will change the value by the smallest digit. Holding the key down will cause the value to change at an increasing rate until the key is released. Pressing the key again will cause the value to start changing at it's slowest rate again. This allows the user to get to the new multiplier value quickly. DRY CALIBRATION K FACTOR 1.0000 > DRY CALIBRATION K FACTOR 1.000 0 UP > DOWN DRY CALIBRATION K FACTOR 10.00 0 > DRY CALIBRATION K FACTOR 10.000 > Press the key once which will move the cursor over the least sign. digit of the display. Use the UP and DOWN keys to adjust the value to the K factor specified on the probe tag Then press to move the cursor to the RH position If the setting is OK, use the key to move the cursor over the Y text and press the down key. If the calibration did not appear to be correct, press the DOWN key which will return back to the Manual Cal Cond menu. DRY CALIBRATION STORE? Y N DOWN DRY CALIBRATION STORE? DOWN Y N Press DOWN to store the calibration data and return back to the Dry Cal Cond menu so the user can select another function. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Conductivity - Calibration Menu - Dry Cal Cond 6.2 Page 48 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Conductivity - Calibration Menu - Temp. Calibration 6.3 Temperature Calibration In most cases, the factory temperature calibration is accurate enough to ensure correct temperature readings. However, in some circumstances, the user may wish to ensure the temperature sensor is calibrated accurately, especially when operating at the extreme end of the conductivity cell temperature operating range, or where the temperature compensation is critical to correct process readings. This menu allows the user to calibrate the temperature anywhere within it's range. Be aware, that the conductivity reading is affected by the temperature reading (due to the temperature compensation) so accurate temperature calibration is vital to obtaining accurate conductivity readings. If the user is unsure of the calibration test fixture, then it would be best to leave the temperature calibration at it's factory setting. Be sure to allow the temperature of the cell to stabilize before attempting to calibrate the temperature sensor, this may take a significant amount of time as the sensor is buried behind a protective layer of epoxy which will cause some delay. 1000uS 25.0C RUN MODE DOWN CALIBRATION If the Temperature Compensation Override is set to ON (see section 6.11), the Shark cannot calibrate the temperature sensor. This display will appear to alert the user to the condition. MANUAL CAL COND DOWN DRY CAL COND DOWN TEMP CALIBRATION TEMP O/R ON TEMP CALIBRATION TEMP CALIBRATION 22.4C DOWN The controller displays the current probe temperature. If this incorrect, the controller can be adjusted to compensate. > DOWN Press the key once which will move the cursor over the least significant digit of the temperature display. TEMP CALIBRATION 22. 4 C UP > > Use the UP and DOWN to adjust the reading until it agrees with the known temperature of the probe DOWN TEMP CALIBRATION 25. 0 C > TEMP CALIBRATION 25.0C > Press the key once which will move the cursor back to the RH side of temperature display. Press the DOWN key to accept the reading and move to the store function DOWN T FACTOR SHIFTED If the calibration did not appear to be correct, press the DOWN key which will return back to the Temp Calibration menu. TEMP CALIBRATION STORE? Y N DOWN "T FACTOR SHIFTED" will be displayed for 5 seconds to indicate that the temperature sensor has been calibrated. The Shark will then move to the store function. TEMP CALIBRATION STORE? Y N DOWN This will store the calibration data and return back to the Temp Calibration setup so the user can select another function. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Conductivity - Calibration Menu - Temp. Calibration 6.3 Page 49 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Conductivity - Utilities Menu - Manual Test Mode 6.4 1000uS 25.0C Manual Test Mode is used to simulate a process reading in order to verify the correct response of the output. When in the Manual Test Mode, the output is no longer placed on hold as it is when in the rest of the menu. RUN MODE DOWN CALIBRATION DOWN UTILITIES MANUAL TEST MODE TEST 1000 > 12.0mA DOWN TEST 100 0 > 12.0mA UP Press the key once which will move the cursor over the least digit of the simulated process value. Use the UP and DOWN keys to change the simulated process value. DOWN TEST 131 0 > 14.4mA The 4-20 mA output will follow the process value change. The 4-20 mA output will track the change in process value TEST 131 0 > 14.4mA TEST 1310 > 14.4mA Press the key once to move the cursor to the RH side of the display Press the DOWN key to return to the MANUAL TEST MODE menu DOWN NOTE: When the user exits the Manual Test Mode, the 4-20mA output will remain in the Test Mode state until the operator enters the run mode. The output will then revert back to the previous On-line state. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Conductivity - Utilities Menu - Manual Test Mode 6.4 Page 50 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Conductivity - Utilities Menu - Meter Selection 6.5 1000uS 25.0C RUN MODE The Meter Selection menu is used to select the meter type that the controller is configured for, either pH, ORP, Conductivity or Flow. Once selected, the controller will initialize itself for the selected meter's functionality and move to run mode. DOWN CALIBRATION DOWN UTILITIES Press the key to initialize the controller as a pH meter. MANUAL TEST MODE DOWN METER SELECTION PH ORP PH INITIALIZE? DOWN Y N DOWN Press the key to initialize the controller as an ORP meter O RP EXIT ORP INITIALIZE? DOWN Y N DOWN Press the key to initialize the controller as a Conductivity meter To reset the controller back to all the factory default values, reselect the current meter type C ONDUCTIVITY FLOW CONDUCTIVITY INITIALIZE? DOWN Y N DOWN Press the key to initialize the controller as a Flow meter F LOW EXIT FLOW INITIALIZE? DOWN Y N DOWN Press the key to Exit and return to the Utilities menu E XIT PH If you do not wish to initialize to this type of meter after all, then press DOWN key to return back to the Meter Selection menu DOWN If you do wish to initialize to this type of meter, press the key to highlight the Y character CONDUCTIVITY INITIALIZE? DOWN Y N Then press DOWN The controller will initialize itself for a specific meter NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Conductivity - Utilities Menu - Meter Selection 6.5 Page 51 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Conductivity - Setup Menu - Conductivity Range 6.6 1000uS 25.0C RUN MODE DOWN CALIBRATION DOWN UTILITIES DOWN SETUP COND. RANGE Conductivity Range will allow the user to select the measuring range of the instrument. The ranges can be selected from any of the following: 200 mS/cm - cell constant 50 20 mS/cm - cell constant 10 5000 uS/cm - cell constant 1 200 uS/cm - cell constant 0.1 20 uS/cm - cell constant 0.1 2 uS/cm - cell constant 0.01 - cell constant 0.01 19.99 MΩ COND. RANGE 5000uS/cm > COND. RANGE 500 0 uS/cm > UP Use the UP or DOWN keys to scroll through the available ranges DOWN COND. RANGE 200. 0 uS/cm UP > DOWN COND. RANGE 20.0 0 uS/cm UP > DOWN COND. RANGE 2.0 0 uS/cm UP > DOWN COND. RANGE 19.9 9 Mo/cm UP > DOWN COND. RANGE 200. 0 mS/cm UP > DOWN COND. RANGE 20.0 0 mS/cm > COND. RANGE 20.00mS/cm > Once the correct range is selected, move to the store function to save the selection Press the key once which will move the cursor back to the RH side of the display. Press the DOWN key to accept the setting and move to the store function DOWN With "N" selected, pressing the DOWN key will NOT store the selection, but simply return to the COND RANGE Menu. This function is useful if you wish to view the current selection without making any changes. Press the key once which will move the cursor over the last character of the range. Or press the the Y character. COND. RANGE STORE? Y N key to highlight COND. RANGE STORE? Y N DOWN Not stored Stored Then press the DOWN key to store the selection and return to the COND RANGE Menu. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Conductivity - Setup Menu - Conductivity Range 6.6 Page 52 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Conductivity - Setup Menu - Temp. Unit 6.7 1000uS 25.0C RUN MODE TEMP UNIT allows the user to select either Degrees Centigrade or Fahrenheit units for display DOWN CALIBRATION DOWN UTILITIES DOWN SETUP COND RANGE DOWN TEMP UNIT TEMP UNIT DEG C > TEMP UNIT DEG C Press the key once which will move the cursor over the unit type, C or F. > UP Use the DOWN TEMP UNIT DEG F TEMP UNIT DEG F DOWN Y N DOWN to select C or F > Press the key once which will move the cursor back to the RH side of the display. > Press the DOWN key to accept the change and move to the store function Or press the the Y character. With "N" selected, pressing the DOWN TEMP UNIT key will NOT store the selection, but STORE? simply return to the TEMP UNIT DOWN Selection Menu. This function is useful if you wish to view the current selection Not stored without making any changes. or UP key to highlight TEMP UNIT STORE? Y N DOWN Stored Then press the DOWN key to store the selection and return to the TEMP UNIT Selection Menu. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Conductivity - Setup Menu - Temp. Unit 6.7 Page 53 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Conductivity - Setup Menu - Temp. Sensor 6.8 1000uS 25.0C RUN MODE TEMP SENSOR allows the user to select the type of temperature sensor used the in the probe. The factory default for Conductivity is a 3000 Ω NTC thermistor. The user can also select a 300 Ω NTC thermistor or a Pt. 1000 RTD. DOWN CALIBRATION DOWN UTILITIES DOWN SETUP COND RANGE DOWN TEMP UNIT TEMP SENSOR TEMP SENSOR 3000 Ω NTC > Press the key once which will move the cursor over to the sensor type. Use the UP or the sensor type TEMP SENSOR 3 000 Ω NTC UP > DOWN TEMP SENSOR 3 00 Ω NTC UP > DOWN to select Once the correct Sensor has been selected press the key once which will move the cursor back to the RH side of the display. DOWN TEMP SENSOR 1 000 Ω RTD > TEMP SENSOR 3000 Ω NTC > DOWN Press the DOWN key to accept the change and move to the store function Or press the the Y character. With "N" selected, pressing the DOWN TEMP SENSOR key will NOT store the selection, but STORE? simply return to the TEMP SENSOR DOWN Selection Menu. This function is useful if you wish to view the current selection without making any changes. Not stored Y N key to highlight TEMP SENSOR STORE? Y N DOWN Stored Then press the DOWN key to store the selection and return to the TEMP SENSOR Selection Menu. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Conductivity - Setup Menu - Temp. Sensor 6.8 Page 54 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Conductivity - Setup Menu - Auto Return 6.9 1000uS 25.0C RUN MODE AUTO RETURN is used to select what conditions will cause the controller to time-out of the operations menu DOWN CALIBRATION DOWN UTILITIES MENU ON will cause the controller to exit the menu and revert back to the online run mode after 10 minutes with no buttons pressed. This feature ensures that if a user forgets to return back to run mode, the controller will not be left in an offline state. If for some reason, the user would like to remain in the menu mode for extended periods of time, the AUTO RETURN function can be set to "OFF". DOWN SETUP COND RANGE DOWN TEMP UNIT DOWN TEMP SENSOR To change the MENU RETURN setting, Press the key once which will move the cursor to the ON or OFF text DOWN AUTO RETURN AUTO RETURN MENU ON > DOWN AUTO RETURN MENU ON UP > DOWN AUTO RETURN MENU O FF > AUTO RETURN MENU OFF > Use the UP or DOWN keys to select either ON or OFF. Press the key once which will move the cursor back to the RH side of the display. DOWN Or press the the Y character. With "N" selected, pressing the DOWN key will NOT store the selection, but simply return to the AUTO RETURN Selection Menu. This function is useful if you wish to view the current selection without making any changes. AUTO RETURN STORE? DOWN Not stored Y N AUTO RETURN STORE? DOWN Stored key to highlight Press the DOWN key to accept the change and move to the STORE function Y N Then press the DOWN key to store the selection and return to the Auto Return Selection Menu. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Conductivity - Setup Menu - Auto Return 6.9 Page 55 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Conductivity - Setup Menu - T. Comp Override 6.10 1000uS 25.0C RUN MODE Temperature Compensation Override is used to manually set the actual probe or process temperature. This is useful if the probe does not have a temperature sensor or if the process temperature is constant. When the override is enabled, the controller will use the selected temperature when performing temperature compensation calculations. DOWN CALIBRATION DOWN UTILITIES DOWN SETUP COND RANGE DOWN TEMP UNIT DOWN TEMP SENSOR DOWN AUTO RETURN Press the key once which will move the cursor to the ON or OFF text DOWN T.COMP OVERRIDE T.COMP OVERRIDE COMPENSATE OFF DOWN > T.COMP OVERRIDE COMPENSATE O FF > UP DOWN T.COMP OVERRIDE COMPENSATE O N > T.COMP OVERRIDE COMPENSATE ON > DOWN Use the UP or DOWN keys to select either ON or OFF. Press the key once which will move the cursor back to the RH side of the Press the DOWN key to accept the change and move to the Temperature Entry function The user can now enter the actual probe or process temperature T.COMP OVERRIDE TEMP 25.4C Press the key once which will move the cursor over the least significant digit of the temperature display. > DOWN NOTE T.COMP OVERRIDE TEMP 25. 4 C PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE UP > DOWN T.COMP OVERRIDE TEMP 35. 7 C > T.COMP OVERRIDE TEMP 35.7C > DOWN Use the UP and DOWN to adjust the reading until it agrees with the known temperature of the probe or process Press the key once which will move the cursor back to the RH side of temperature display. Press the DOWN key to accept the reading and move to the store function If you wish to save the setting, press the key to highlight the Y character With "N" selected, pressing the DOWN key will NOT store the selection, but simply return to the T. Comp Override Menu. This function is useful if you wish to view the current selection without making any changes. T.COMP OVERRIDE STORE? Y N DOWN Not stored Conductivity - Setup Menu - T. Comp Override 6.10 T.COMP OVERRIDE STORE? Y N DOWN Stored Then press the DOWN key to store the selection and return to the T. COMP OVERRIDE Menu. Page 56 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Conductivity - Setup Menu - Display Damping 6.11 1000uS 25.0C RUN MODE DOWN CALIBRATION DOWN UTILITIES The Display Damping menu allows the user to adjust the rate at which the display and the output is updated. This allows the user to dampen out unstable process readings. The damping can be set from 0 seconds to 10 seconds. (default value is 0 sec.) DOWN SETUP COND RANGE DOWN TEMP UNIT DOWN TEMP SENSOR DOWN AUTO RETURN DOWN Press the key once which will move the cursor over the seconds digit T.COMP OVERRIDE DOWN DISPLAY DAMPING DISPLAY DAMPING UPDATE 0 SEC > DOWN DISPLAY DAMPING UPDATE 0 SEC UP > DOWN Press the key once which will move the cursor back to the RH side of the display. DISPLAY DAMPING UPDATE 1 0 SEC > DISPLAY DAMPING UPDATE 10 SEC > DOWN Use the UP and DOWN to adjust the damping time, the default setting is 0 seconds. The setting can be adjusted from 0 to 10 seconds. Press the DOWN key to accept the setting and move to the store function If you wish to save the setting, press the key to highlight the Y character With "N" selected, pressing the DOWN key will NOT store the selection, but simply return to the Display Damping Menu. This function is useful if you wish to view the current selection without making any changes. DISPLAY DAMPING STORE? Y N DOWN DISPLAY DAMPING STORE? Y N DOWN Not stored Stored Then press the DOWN key to store the selection and return to the Display Damping Menu. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Conductivity - Setup Menu - Display Damping 6.11 Page 57 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Conductivity - Setup Menu - Temp. Comp. Curve 6.12 1000uS 25.0C The Temperature Compensation Curve setting allows the user to select the temperature compensation to match a specific process. The variation of Conductivity versus Temperature is dependent on the type of solids and liquids in water, so no fixed compensation value will accurately compensate every process. This setting allows the user to fine tune the compensation to their specific process. Estimates of the correct compensation for certain chemicals are available and can be preset via this menu, otherwise the user will need to set the compensation to 0%/C, measure the effect of temperature for a specific process, calculate the actual compensation required and enter it through this menu. The Compensation can be varied from 0%/C to 10%/C. RUN MODE DOWN CALIBRATION DOWN UTILITIES DOWN SETUP COND RANGE DOWN TEMP UNIT DOWN TEMP SENSOR DOWN AUTO RETURN DOWN T.COMP OVERRIDE DOWN DISPLAY DAMPING DOWN TEMP COMP CURVE Press the key once which will move the cursor over the least digit TEMP COMP CURVE 2.0%/C > TEMP COMP CURVE 2. 0 %/C > Use the UP and DOWN to adjust the percent compensation. The setting can be changed from 0%/C to 10%/C TEMP COMP CURVE 2. 5 %/C > TEMP COMP CURVE 2.5%/C Press the key once which will move the cursor back to the RH side of the display. > UP DOWN Press the DOWN key to accept the setting and move to the store function DOWN With "N" selected, pressing the key will NOT store the selection, but simply return to the Temp Cond Curve setting menu. This function is useful if you wish to view the current selection without making any changes. DOWN If you wish to save the setting, press the key to highlight the Y character TEMP COMP CURVE STORE? Y N DOWN TEMP COMP CURVE STORE? Y N DOWN Not stored Stored Then press the DOWN key to store the selection and return to Temp Cond Curve settting menu. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Conductivity - Setup Menu - Temp. Comp. Curve 6.12 Page 58 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Conductivity - Diagnostics Menu - Firmware Rev. 6.13 1000uS 25.0C RUN MODE DOWN The FIRMWARE REV menu allows the user to see what revision of the firmware is currently installed in the controller. This is a Read Only menu item. CALIBRATION DOWN UTILITIES DOWN SETUP DOWN DIAGNOSTICS FIRMWARE REV. FIRMWARE REV. 1.00 DOWN Conductivity - Diagnostics Menu - Firmware Rev. 6.13 NOTE > PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Page 59 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Conductivity - Diagnostics Menu - Calibration Data 6.14 1000uS 25.0C RUN MODE The Calibration Data menu is a series of read only screens which allow the user to view the data collected during the last calibration. DOWN CALIBRATION DOWN UTILITIES DOWN SETUP DOWN DIAGNOSTICS FIRMWARE REV. DOWN Press to view the first Calibration Data screen. CALIBRATION DATA TYPICAL DISPLAYS FOR MANUAL CAL CALIBRATION DATA MODE 1PT > Press DOWN to view the next Calibration Data screen. DOWN CALIBRATION DATA 1P 1000/1000 Ω Calibration Mode 1 point calibration > DOWN > Calculated Cell Constant CALIBRATION DATA K FACTOR 1.0000 Calibration Mode Dry Cal Press DOWN to view the next Calibration Data screen. DOWN CALIBRATION DATA 1P - - - - > No Buffer used in this Calibration Mode DOWN > DOWN CALIBRATION DATA CAL TEMP 25.2C CALIBRATION DATA MODE DRY Conductivity of Buffer/ Input Resistance DOWN CALIBRATION DATA K FACTOR 0.9774 TYPCIAL DISPLAYS FOR DRY CAL Cell Constant Setting > DOWN > Probe Temperature at which calibration was performed = 25.2° C CALIBRATION DATA CAL TEMP - - - DOWN > Dry Cal does not use a buffer, so Probe Temperature was not recorded NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Conductivity - Diagnostics Menu - Calibration Data 6.14 Page 60 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Conductivity - Diagnostics Menu - Sensor Input 6.15 1000uS 25.0C RUN MODE DOWN CALIBRATION DOWN The Sensor Input Menu allows the user to view real time, uncompensated process data from the conductivity cell. This is a Read only menu item. This "Live Data" screen is useful for trouble shooting purposes when diagnosing cell or process problems. UTILITIES DOWN SETUP DOWN DIAGNOSTICS FIRMWARE REV. DOWN CALIBRATION DATA DOWN SENSOR INPUT Press to view the Sensor Input data. CELL 966 TEMP 2953 Ω Ω > The top line shows the resistance of the cell, The bottom line shows the actual value of the temperature sensor in ohms. DOWN NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Conductivity - Diagnostics Menu - Sensor Input 6.15 Page 61 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Conductivity - Output Menu - 4-20mA Output 6.16 RUN MODE 1000uS 25.0C The Transmitter has a single 4-20mA output, electrically isolated from the ground. The output can source current into a maximum of 800 ohms. See Section 3.9 for wiring diagram. The channel has a fully adjustable 4 & 20 mA output adjustments. This will enable the operator to span the output over the desired range. DOWN CALIBRATION DOWN UTILITIES DOWN SETUP The example below shows the 4-20 mA set to 4mA =400 uS and 20mA = 1800 uS. The output would then span 4 to 20 mA for a conductivity swing of 400 to 1800. Note that the span can reversed, in that 4 mA can be set to a high conductivity value, and 20 mA can be set to a low conducivity value, effectively reversing the control direction. DOWN DIAGNOSTICS DOWN 4-20mA OUTPUT If you wish to change the setting, press the key once which will move the cursor to the first character of the value to be changed 4-20mA PROC 4mA OUT 0 > DOWN UP NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE The TUNE fuction allows the user to precisely adjust the 4-20 mA output to compensate for any errors in the output circuitry. Normally, fine tuning the 4-20mA output is not necessary. 4-20mA PROC The make the adjustment, place an 20mA OUT 2000 accurate current meter in series with the 4-20 mA output, with the appropriate loads DOWN connected. When the TUNE menu is selected, the controller puts 20 mA out the terminals. Use the UP or DOWN keys to adjust the 20mA output to get exactly 20. The TUNE value can be adjusted over the range from 0 to 1000, these are unitless numbers used for tuning purposes only. With "N" selected, pressing the DOWN key will NOT store the selection, but simply return to the OUTPUT Menu. This function is useful if you wish to view the current selection without making any changes. Not stored > DOWN > 4-20mA PROC 4mA OUT 400 > 4-20mA PROC 20mA OUT 200 0 UP > DOWN 4-20mA PROC 20mA OUT 180 0 > 4-20mA PROC 20mA OUT 1800 > DOWN Press the key once which will move the cursor back to the RH side of the display. Press the DOWN key to accept the setting and move to the next setting Use the UP and DOWN keys to change the setting Press the key once which will move the cursor back to the RH side of the display. Press the DOWN key to accept the setting and move to the next setting If you wish to change the setting, press the key once which will move the cursor to the first character of the value to be changed 4-20mA PROC 20mA TUNE 512 > Or press the key to highlight the Y character Stored 4-20mA PROC STORE? 4-20mA PROC 4mA OUT 40 0 Use the UP and DOWN keys to change the setting If you wish to change the setting, press the key once which will move the cursor to the first character of the value to be changed Y N DOWN > DOWN DOWN DOWN 4-20mA PROC STORE? 4-20mA PROC 4mA OUT 0 4-20mA PROC 20mA TUNE 51 2 UP > DOWN 4-20mA PROC 20mA TUNE 54 0 > 4-20mA PROC 20mA TUNE 540 > DOWN Use the UP and DOWN keys to change the setting Press the key once which will move the cursor back to the RH side of the display. Press the DOWN key to accept the setting and move to the next setting Y N Then press the DOWN key to store the selection and return to the OUTPUT menu Conductivity - Output Menu - 4-20mA Output 6.16 Page 62 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Section 7 - Using the Transmitter in Flow Mode 1/4" TURN SCREWS (FOR SHARKTX ONLY) 2 LINE, 16 CHARACTER LCD DISPLAY MAIN MENU INTERFACE SCREEN UNIT LABEL LABEL TO INDICATE UNIT OF MEASURE SHARK IS CONFIGURED FOR. SIMPLE THREE-BUTTON INTERFACE FOR FAST & EASY SETUP (REFER TO SECTIONS 7.0 TO 7.14) Section 7 - Using the Transmitter in Flow Mode Page 63 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Flow - Menu Overview 7.0 RUN MODE TOTAL 0 DOWN CALIBRATION DOWN K FACTOR UTILITIES DOWN DOWN ENTER FLOW SENSOR CALIBRATION FACTOR SEC. 7.1 EXIT SETUP DOWN DOWN DIAGNOSTICS DOWN OUTPUT MANUAL TEST MODE DOWN DOWN EXIT METER SELECTION DOWN DOWN UNITS OF VOLUME DOWN UNITS OF TIME DOWN AUTO RETURN DOWN DISPLAY DAMPING DOWN TOTALIZER RESET DOWN SETUP OF UNITS OF VOLUME SEC. 7.4 SETUP OF UNITS OF TIME SEC. 7.5 ENABLE TIME OUT FROM MENU SEC. 7.6 SETUP DISPLAY AND OUTPUT RESPONSE TIME SEC 7.7 RESET TOTALIZER TO ZERO SEC 7.8 SIMULATE PROCESS VERIFY OUTPUTS SEC. 7.2 SELECT TYPE OF METER SEC. 7.3 EXIT DOWN EXIT DOWN FIRMWARE REV DOWN CALIBRATION DATA DOWN SENSOR INPUT DOWN PERMANENT TOTAL DOWN TOTAL ROLLOVER DOWN DISPLAY FIRMWAVE REVISION SEC 7.9 DISPLAY PREVIOUS CALIBRATION DATA SEC 7.10 DISPLAY UNCALIBRATED SENSOR INPUT SEC 7.11 DISPLAY PERMANENT TOTALIZER SEC 7.12 DISPLAY TOTALIZER ROLLOVERS TO DATE SEC 7.13 EXIT DOWN 4-20mA DOWN SETUP 4-20 mA OUTPUT SEC 7.14 EXIT DOWN Flow - Menu Overview 7.0 NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Page 64 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Flow - Calibration Menu - K Factor 7.1 The K Factor menu is used to enter the flow sensor calibration factor. The K Factor represents the number of pulses per U.S. Gallon, generated by the combination of sensor and flow fitting. It is normally stamped on the flow fitting or attached to a tag on the cable. Typical K factors range between 0.5000 to 1500.0. TOTAL 0 To enter the K factor, use the DOWN key to enter the Calibration menu and then the key to select the K Factor menu. RUN MODE DOWN CALIBRATION K FACTOR K FACTOR 100.00 > DOWN Press the key once which will move the cursor over the least sign. digit of the display. If you just wish to view the current K Factor without changing it, press the DOWN key which will move to the store function NOTE: ACCELERATOR KEYS Pressing the UP or DOWN key once will change the value by the smallest digit. Holding the key down will cause the to value change at an increasing rate until the key is released. Pressing the key again will cause the value to start changing at it's slowest rate again. This allows the user to get to the new K Factor value quickly. K FACTOR 100.0 0 > UP DOWN K FACTOR 125.0 0 > K FACTOR 125.00 The K Factor can be set anywhere from 0.5000 pulses per U.S.Gallon to 1500.0 pulses per U.S.Gallon Then press to move the cursor to the RH position > DOWN If the calibration did not appear to be correct, press the DOWN key which will return back to the K Factor menu without storing the value. Use the UP and DOWN keys to adjust the reading until it agrees with the actual K Factor as specified on the sensor Press the DOWN key to accept the change and move to the store function If the K Factor setting is OK, use the key to move the cursor over the Y text and press the down key. K FACTOR STORE? Y N DOWN K FACTOR STORE? Y N DOWN Press DOWN to store the calibration data and return back to the menu so the user can select another function. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Flow - Calibration Menu - K Factor 7.1 Page 65 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Flow - Utilities Menu - Manual Test Mode 7.2 TOTAL 0 Manual Test Mode is used to simulate a process reading in order to verify the correct response of the output. When in the Manual Test Mode, the output is no longer placed on hold as it is when in the rest of the menu. RUN MODE DOWN CALIBRATION DOWN UTILITIES MANUAL TEST MODE TEST 50.00 GPM > 12.0mA DOWN TEST 50.0 0 GPM > 12.0mA UP TEST Press the key once which will move the cursor over the least digit of the simulated process value. Use the UP and DOWN keys to change the simulated process value. DOWN 65.0 0 GPM > 14.4mA The 4-20 mA output will follow the process value change. The 4-20 mA output will track the change in process value TEST 65.0 0 GPM > 14.4mA TEST 65.00 GPM > 14.4mA Press the key once to move the cursor to the RH side of the display Press the DOWN key to return to the MANUAL TEST MODE menu DOWN NOTE: When the user exits the Manual Test Mode, the 4-20mA output will remain in the Test Mode state until the operator enters the run mode. The output will then revert back to the previous On-line state. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Flow - Utilities Menu - Manual Test Mode 7.2 Page 66 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Flow - Utilities Menu - Meter Selection 7.3 TOTAL 0 RUN MODE The Meter Selection menu is used to select the meter type that the controller is configured for, either pH, ORP, Conductivity or FLow. Once selected, the controller will initialize itself for the selected meter's functionality and move to run mode. DOWN CALIBRATION DOWN UTILITIES MANUAL TEST MODE Press the key to initialize the controller as a pH meter. DOWN METER SELECTION PH ORP PH INITIALIZE? DOWN Y N DOWN Press the key to initialize the controller as an ORP meter O RP CONDUCTIVITY ORP INITIALIZE? DOWN To reset the controller back to all the factory default values, reselect the current meter type Y N DOWN Press the key to initialize the controller as a Conductivity meter C ONDUCTIVITY FLOW CONDUCTIVITY INITIALIZE? DOWN Y N DOWN Press the key to initialize the controller as a Flow meter F LOW EXIT FLOW INITIALIZE? DOWN Y N DOWN Press the key to Exit and return to the Utilities menu E XIT PH If you do not wish to initialize to this type of meter after all, then press DOWN key to return back to the Meter Selection menu DOWN If you do wish to initialize to this type of meter, press the key to highlight the Y character Then press DOWN The controller will initialize itself for a specific meter FLOW INITIALIZE? Y N DOWN NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Flow - Utilities Menu - Meter Selection 7.3 Page 67 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Flow - Setup Menu - Units of Volume 7.4 The Units of Measurement is broken into two variables, UNITS OF VOLUME and UNITS OF TIME. The two variables are then combined to display the desired units of measure. For example, if units of Volume is to set Cubic Meters (CM) and Units of Time is set for Seconds (S), the controller will display flow as Cubic Meters per Second on the front LED display. TOTAL UNITS OF VOLUME The user can select from four predefined units of Volume, or create their own custom value. The four predefined units are US Gallons GP Cubic Feet CF Liters LP Cubic Meters CM The user can also select any two custom characters to represent units from AA to ZZ and an input multiplier which will numerically relate the custom unit of measure to US Gallons. The input multiplier can be set at any value between 0.0001 and 10000. RUN MODE 0 DOWN CALIBRATION DOWN UTILITIES DOWN SETUP UNITS OF VOLUME US GALLONS GP UNITS OF VOLUME UNITS OF VOLUME US GALLONS GP W A R N I N G UP > DOWN Changing the units of Volume with an accumulated flow total will reset the flow total to zero. UNITS OF VOLUME CUBIC FEET CF Example: If the controller has been running in GPM mode and has a totalized flow, changing from GPM to another unit will reset the totalizer to zero. UNITS OF VOLUME LITERS LP UP Use the UP or DOWN keys to scroll through the available ranges To select a specific predefined unit, press the key once which will move the cursor back to the RH side of the display. UNITS OF VOLUME CUBIC FEET CF > DOWN UP Press the key once which will move the cursor over the last character of the volume unit setting. > > Press the DOWN key to accept the setting and move to the store function DOWN > DOWN UNITS OF VOLUME CUBIC METER CM UP > DOWN UNITS OF VOLUME CUSTOM ?? To select custom units, press the, press the key, then the DOWN key, which will move the cursor back to the right hand digit of the custom unit character. UNITS OF VOLUME CUSTOM ?? > In this example, the units will be changed to ML (milliliters), and the multiplier changed to 3785.4 since one U.S. Gallon equals 3785.4 milliliters. > DOWN NOTE: ACCELERATOR KEYS Pressing the UP or DOWN key once will change the value by the smallest digit. Holding the key down will cause the value to change at an increasing rate until the key is released. Pressing the key again will cause the value to start changing at it's slowest rate again. This allows the user to get to the new multiplier value quickly. UNITS OF VOLUME CUSTOM ?? UP Use the or DOWN appropriate text character, then press the key to move to the left hand text character DOWN UNITS OF VOLUME CUSTOM ?L UP > keys to select the > UNITS OF VOLUME CUSTOM ?? UP UNITS OF VOLUME CUSTOM ML UNITS OF VOLUME CUSTOM ML > > DOWN Press the key once which will move the cursor over the smallest digit of the custom multiplier. UNITS OF VOLUME CUSTOM 1.0000 > UNITS OF VOLUME CUSTOM 1.000 0 > DOWN UNITS OF VOLUME CUSTOM 3785. 4 NOTE PRESS THE AND KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE DOWN DOWN Press the DOWN key to accept the setting and move to the custom multiplier setting. UP UP Again, use the UP or DOWN keys to select the appropriate text character, then press the key to move the cursor to the RH position. > With "N" selected, pressing the DOWN key will NOT store the selection, but simply return to the UNITS OF VOLUME Menu. This function is useful if you UNITS OF VOLUME wish to view the current STORE? Y N selection without making any changes. Not stored Flow - Setup Menu - Units of Volume 7.4 > Use the UP or DOWN keys to select the correct multiplier. When complete, press the key to Setting the custom move the cursor to the RH position. Units of Volume and Multiplier is now UNITS OF VOLUME complete, press the CUSTOM 3785.4 > DOWN key to accept DOWN the setting and move to the store function Or press the the Y character. key to highlight UNITS OF VOLUME STORE? Y N Stored DOWN Then press the DOWN key to store the selection and return to the UNITS OF VOLUME menu. Page 68 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Flow - Setup Menu - Units of Time 7.5 TOTAL 0 DOWN CALIBRATION DOWN UTILITIES RUN MODE The Units of Measurement is broken into two variables, UNITS OF VOLUME and UNITS OF TIME. The two variables are then combined to display the desired units of measure. For example, if units of Volume is to set Cubic Meters (CM) and Units of Time is set for Seconds (S), the controller will display flow as Cubic Meters per Second on the front LED display. UNITS OF TIME The user can select from four predefined Units of Time, Seconds, Minutes, Hours, Days. DOWN SETUP UNITS OF VOLUME DOWN UNITS OF TIME UNITS OF TIME SECONDS S > UNITS OF TIME SECONDS S > UP Press the key once which will move the cursor over the last character of the time unit setting. Use the UP or DOWN keys to scroll through the available ranges DOWN UNITS OF TIME MINUTES M UP > UNITS OF TIME MINUTES M DOWN Press the DOWN key to accept the setting and move to the store function UNITS OF TIME HOURS H UP > DOWN UNITS OF TIME DAYS D UP > DOWN Or press the the Y character. With "N" selected, pressing the DOWN key will NOT store the selection, but simply return to the UNITS OF TIME Selection Menu. This function is useful if you wish to view the current selection without making any changes. > DOWN UNITS OF TIME STORE? DOWN Not stored Y N key to highlight UNITS OF TIME STORE? Y N DOWN Stored Then press the DOWN key to store the selection and return to the UNITS OF TIME Selection Menu. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Flow - Setup Menu - Units of Time 7.5 Page 69 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Flow - Setup Menu - Auto Return 7.6 TOTAL 0 RUN MODE AUTO RETURN is used to select what conditions will cause the controller to time-out of the operations menu DOWN CALIBRATION DOWN MENU ON will cause the controller to exit the menu and revert back to the online run mode after 10 minutes with no buttons pressed. This feature ensures that if a user forgets to return back to run mode, the controller will not be left in an offline state. If for some reason, the user would like to remain in the menu mode for extended periods of time, the AUTO RETURN function can be set to "OFF". UTILITIES DOWN SETUP UNITS OF VOLUME DOWN UNITS OF TIME To change the MENU RETURN setting, Press the key once which will move the cursor to the ON or OFF text DOWN AUTO RETURN AUTO RETURN MENU ON > DOWN AUTO RETURN MENU O N UP AUTO RETURN MENU O FF > AUTO RETURN MENU OFF > DOWN Or press the the Y character. With "N" selected, pressing the DOWN key will NOT store the selection, but simply return to the AUTO RETURN Selection Menu. This function is useful if you wish to view the current selection without making any changes. AUTO RETURN STORE? DOWN Not stored Y N > DOWN AUTO RETURN STORE? DOWN Stored Use the UP or DOWN keys to select either ON or OFF. Press the key once which will move the cursor back to the RH side of the display. Press the DOWN key to accept the change and move to the STORE function key to highlight Y N Then press the DOWN key to store the selection and return to the Auto Return Selection Menu. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Flow - Setup Menu - Auto Return 7.6 Page 70 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Flow - Setup Menu - Display Damping 7.7 TOTAL 0 RUN MODE DOWN CALIBRATION DOWN UTILITIES The Display Damping menu allows the user to adjust the rate at which the display and the output is updated. This allows the user to dampen out unstable process readings. The damping can be set from 0 seconds to 10 seconds. (default value is 0 sec.) DOWN SETUP UNITS OF VOLUME DOWN UNITS OF TIME DOWN AUTO RETURN DOWN DISPLAY DAMPING DISPLAY DAMPING UPDATE 0 SEC Press the key once which will move the cursor over the seconds digit > DOWN DISPLAY DAMPING UPDATE 0 SEC UP > DOWN Use the UP and DOWN to adjust the damping time, the default setting is 0 seconds. The setting can be adjusted from 0 to 10 seconds. Press the key once which will move the cursor back to the RH side of the display. DISPLAY DAMPING UPDATE 1 0 SEC > DISPLAY DAMPING UPDATE 10 SEC > DOWN With "N" selected, pressing the DOWN key will NOT store the selection, but simply return to the Display Damping Menu. This function is useful if you wish to view the current selection without making any changes. Press the DOWN key to accept the setting and move to the store function If you wish to save the setting, press the key to highlight the Y character DISPLAY DAMPING STORE? Y N DOWN DISPLAY DAMPING STORE? Y N DOWN Not stored Stored Then press the DOWN key to store the selection and return to the Display Damping Menu. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Flow - Setup Menu - Display Damping 7.7 Page 71 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Flow - Setup Menu - Totalizer Reset 7.8 TOTAL 0 RUN MODE Totalizer Reset is used to reset the Flow totalizer to zero. DOWN Note that once complete, this action cannot be reversed. The accumulated total will be erased permanently. CALIBRATION DOWN UTILITIES DOWN SETUP UNITS OF VOLUME DOWN UNITS OF TIME DOWN AUTO RETURN DOWN DISPLAY DAMPING DOWN TOTALIZER RESET TOTALIZER RESET RESET? If you wish to reset the totalizer, press the key to highlight the Y character Y N DOWN TOTALIZER RESET RESET? If you do not wish to reset the totalizer, Press the DOWN key which will return back to the Totalizer Reset menu DOWN TOTALIZER RESET CONFIRM If you do not wish to reset the totalizer, Press the DOWN key which will return back to the Totalizer Reset menu Y N then Press the the action. DOWN key to confirm The controller will ask once more, If you wish to reset the totalizer, press the key to highlight the Y character Y N DOWN TOTALIZER RESET CONFIRM DOWN Y N then Press the the action. DOWN key to complete TOTALIZER RESET TO 0 The controller will confirm the action and return back to the Totalizer Reset menu. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Flow - Setup Menu - Totalizer Reset 7.8 Page 72 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Flow - Diagnostics Menu - Firmware Rev 7.9 TOTAL 0 RUN MODE DOWN CALIBRATION The FIRMWARE REV menu allows the user to see what revision of the firmware is currently installed in the controller. This is a Read Only menu item. DOWN UTILITIES DOWN SETUP DOWN DIAGNOSTICS FIRMWARE REV. FIRMWARE REV. 1.00 > DOWN NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Flow - Diagnostics Menu - Firmware Rev 7.9 Page 73 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Flow - Diagnostics Menu - Calibration Data 7.10 TOTAL 0 RUN MODE The Calibration Data menu is a read only screen which allow the user to view the K factor entered during the last calibration. DOWN CALIBRATION DOWN UTILITIES DOWN SETUP DOWN DIAGNOSTICS FIRMWARE REV. DOWN CALIBRATION DATA Press to view the first Calibration Data screen. CALIBRATION DATA K FACTOR 125.00 DOWN This screen shows the K factor entered during calibration. > Press DOWN to return to the Calibration Data menu. NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Flow - Diagnostics Menu - Calibration Data 7.10 Page 74 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Flow - Diagnostics Menu - Sensor Input 7.11 TOTAL 0 RUN MODE The Sensor Input Menu allows the user to view real time signals from the probe. The display will show the current input pulse rate in Hz (pulses per second). DOWN CALIBRATION DOWN UTILITIES DOWN SETUP DOWN DIAGNOSTICS FIRMWARE REV. DOWN CALIBRATION DATA DOWN SENSOR INPUT Press to view the Sensor Input data. FREQ 101 Hz Press menu. DOWN to return to the DOWN NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Flow - Diagnostics Menu - Sensor Input 7.11 Page 75 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Flow - Diagnostics Menu - Permanent Total 7.12 TOTAL 0 RUN MODE The Permanent Total is a running total of all the volume units that have been accumulated by the controller. It starts at zero when new, and can only be set to zero at the factory. DOWN CALIBRATION DOWN This is a read only screen. UTILITIES DOWN SETUP DOWN DIAGNOSTICS FIRMWARE REV. DOWN CALIBRATION DATA DOWN SENSOR INPUT DOWN PERMANENT TOTAL Press to view the Total Life Flow to date. TOTAL LIFE FLOW 7421413 > Press menu. DOWN to return to the DOWN NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Flow - Diagnostics Menu - Permanent Total 7.12 Page 76 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Flow - Diagnostics Menu - Total Rollover 7.13 TOTAL 0 RUN MODE The Total Rollover menu is another read only screen. It is used to indicate how many times the Permanent and Resetable Totalizers have rolled over during the life of the controller. DOWN CALIBRATION DOWN UTILITIES DOWN SETUP DOWN DIAGNOSTICS FIRMWARE REV. DOWN CALIBRATION DATA PER indicate the number of times the Permanent Totalizer has rolled over. DOWN SENSOR INPUT RST indicates the number of times the Resetable Totalizer has rolled over. DOWN PERMANENT TOTAL DOWN TOTAL ROLLOVER Press to view the Totalizer Rollovers to date. TOTAL ROLLOVER PER 0 RST 0 > Press menu. DOWN to return to the DOWN NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE Flow - Diagnostics Menu - Total Rollover 7.13 Page 77 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Flow - Output Menu - 4-20mA Output 7.14 TOTAL RUN MODE 0 The Transmitter has a single 4-20mA output, electrically isolated from the ground. The output can source current into a maximum of 800 ohms. See Section 3.9 for wiring diagram. The channel has a fully adjustable 4 & 20 mA output adjustments. This will enable the operator to span the output over the desired range. DOWN CALIBRATION DOWN UTILITIES DOWN The example below shows the 4-20 mA set to 4mA = 20 and 20mA = 90. The output would then span 4 to 20 mA for a flow swing of 20 to 90. Note that the span can reversed, in that 4 mA can be set to a high flow value and 20 mA can be set to a low flow value, effectively reversing the control direction. SETUP DOWN DIAGNOSTICS DOWN 4-20mA OUTPUT If you wish to change the setting, press the key once which will move the cursor to the first character of the value to be changed 4-20mA PROC 4mA OUT 0.00 DOWN NOTE PRESS THE UP AND DOWN KEYS TOGETHER TO GO IMMEDIATELY BACK TO RUN MODE > 4-20mA PROC 4mA OUT 0.0 0 UP > DOWN 4-20mA PROC 4mA OUT 20.0 0 > 4-20mA PROC 4mA OUT 20.00 > DOWN The TUNE fuction allows the user to If you wish to change the setting, press the precisely adjust the 4-20 mA output to key once which will move the cursor to the first compensate for any errors in the output character of the value to be changed circuitry. Normally, fine tuning the 4-20mA output is not necessary. 4-20mA PROC 4-20mA PROC The make the adjustment, place an 20mA OUT 100.00 > 20mA OUT 100.0 0 accurate current meter in series with the DOWN UP DOWN 4-20 mA output, with the appropriate loads connected. When the TUNE menu 4-20mA PROC is selected, the controller puts 20 mA out 20mA OUT 90.0 0 the terminals. Use the UP or DOWN keys to adjust the 20mA output to get 4-20mA PROC exactly 20. 20mA OUT 90.00 The TUNE value can be adjusted over the range from 0 to 1000, these are unitless DOWN numbers used for tuning purposes only. If you wish to change the setting, press the With "N" selected, pressing the DOWN key once which will move the cursor to the first key will NOT store the selection, but character of the value to be changed simply return to the OUTPUT Menu. This 4-20mA PROC function is useful if you wish to view the 4-20mA PROC 20mA TUNE 512 > 20mA TUNE 51 2 current selection without making any changes. DOWN UP DOWN 4-20mA PROC STORE? Not stored Y N Or press the key to highlight Stored the Y character > > DOWN Press the DOWN key to accept the setting and move to the next setting Use the UP and DOWN keys to change the setting Press the key once which will move the cursor back to the RH side of the display. Press the DOWN key to accept the setting and move to the next setting > > 4-20mA PROC 20mA TUNE 540 > DOWN 4-20mA PROC STORE? Press the key once which will move the cursor back to the RH side of the display. > 4-20mA PROC 20mA TUNE 54 0 DOWN Use the UP and DOWN keys to change the setting Use the UP and DOWN keys to change the setting Press the key once which will move the cursor back to the RH side of the display. Press the DOWN key to accept the setting and move to the next setting Y N Then press the DOWN key to store the selection and return to the OUTPUT menu Flow - Output Menu - 4-20mA Output 7.14 Page 78 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Appendix A - Probe Configuration Table Model# Probe Select Temp. Sensor Model# Probe Select Temp. Sensor P60C-4 DIFFERENTIAL 300Ω R60C-4 DIFFERENTIAL 300Ω P60C-4-A DIFFERENTIAL 300Ω R60C-4-H DIFFERENTIAL 300Ω P60C-4-H DIFFERENTIAL 300Ω R60C-4-G DIFFERENTIAL 300Ω P60C-6 DIFFERENTIAL 300Ω R60C-6 DIFFERENTIAL 300Ω P60C-6-H DIFFERENTIAL 300Ω R60C-6-H DIFFERENTIAL 300Ω P60C-6-F DIFFERENTIAL 300Ω R60C-6-G DIFFERENTIAL 300Ω P60C-7 DIFFERENTIAL 300Ω R60C-7 DIFFERENTIAL 300Ω P60C-7-H DIFFERENTIAL 300Ω R60C-7-H DIFFERENTIAL 300Ω P60C-7-F DIFFERENTIAL 300Ω R60C-7-G DIFFERENTIAL 300Ω P60C-8 DIFFERENTIAL 300Ω R60C-8 DIFFERENTIAL 300Ω P60C-8-A DIFFERENTIAL 300Ω R60C-8-H DIFFERENTIAL 300Ω P60C-8-H DIFFERENTIAL 300Ω R60C-8-G DIFFERENTIAL 300Ω P60C-S DIFFERENTIAL 300Ω R60C-S DIFFERENTIAL 300Ω P60C-S-F DIFFERENTIAL 300Ω R60C-S-F DIFFERENTIAL 300Ω AM6010-PO DIFFERENTIAL 300Ω AM2010-RO DIFFERENTIAL 300Ω AM6070-PO DIFFERENTIAL 300Ω AM2070-RO DIFFERENTIAL 300Ω P525 COMBINATION no. temp. sensor AM2010-R1 DIFFERENTIAL 300Ω P525-BNC COMBINATION no. temp. sensor AM2070-R1 DIFFERENTIAL 300Ω P575 COMBINATION no. temp. sensor R525 COMBINATION no. temp. sensor P575K-1 COMBINATION Pt. 1000 RTD R525-BNC COMBINATION no. temp. sensor P575K-2 COMBINATION 300Ω R575 COMBINATION no. temp. sensor P575-BNC COMBINATION no. temp. sensor R575-BNC COMBINATION no. temp. sensor P585 COMBINATION no. temp. sensor R585 COMBINATION no. temp. sensor P585K-1 COMBINATION Pt. 1000 RTD R585-BNC COMBINATION no. temp. sensor P585K-2 COMBINATION 300Ω R565 COMBINATION no. temp. sensor P585-BNC COMBINATION no. temp. sensor R565L COMBINATION no. temp. sensor P565 COMBINATION no. temp. sensor P565L COMBINATION no. temp. sensor Appendix A - Probe Configuration Table Page 79 MULTI-PARAMETER TRANSMITTER USER’S MANUAL Return Policy & Warranty Plan AQUAMETRIX, INC. RETURN POLICY 1. Contact Aquametrix for a “Return Material Authorization” (RMA) form & number. This RMA number is required for all returns or they will not be accepted. 2. The RMA number must be written on the outside of the box for proper identification. 3. A copy of the RMA form along with a description of the problem, model & serial number must be attached with the returning item(s). 4. All C.O.D. & freight collect shipments will be refused unless authorized by AquaMetrix. 5. Shipping documents must indicate "RETURNING FOR REPAIR ONLY, NO COMMERCIAL VALUE". 12-MONTH AQUAMETRIX WARRANTY REPLACEMENT PLAN AquaMetrix, Inc. will replace or repair any AquaMetrix SHARKTX or SHARKTXP transmitter that fails due to defects in material or workmanship for a period of up to 12 months from the date of shipment from our facility. A warranty claim will not be honored if defects are not reported within the warranty period, or if AquaMetrix determines that defects or damages are due to normal wear, misapplication, lack of maintenance, abuse, improper installation, alteration, or abnormal conditions. AquaMetrix’s obligation under this warranty shall be limited to, at its option, replacement or repair of this product. The product must be returned to AquaMetrix Inc, freight prepaid, for examination. The product must be accompanied with an MSDS for all the process chemicals used, must be thoroughly cleaned and any process chemicals removed before it will be accepted for replacement or repair. AquaMetrix liability shall not exceed the cost of the product. Under no circumstances will AquaMetrix be liable for any incidental or consequential damages, whether to person or property. AquaMetrix will not be liable for any other loss, damage or expense of any kind, including loss of profits, resulting from the installation, use, or inability to use this product. Return Policy & Warranty Plan Page 80