Transcript
Profibus 8.2.25 Module 24: Min/Max velocity Description The Min/Max velocity function monitors the velocity value and transfers the maximum and minimum value to the PROFIBUS master. Recording can be controlled via module 22 "Velocity measurement control". It is also possible to reset values to the initialization value via module 22. Parameter none Input Data Input Data Description Address Data Type Value Range Init Value Unit Minimum velocity Minimum velocity for detected period 0 UNSIGNED 32 0 … 10’000’000 0 scaled Maximum velocity Maximum velocity for detected period 4 UNSIGNED 32 0 … 10’000’000 0 scaled Table 8-39: Input data for module 24 Input data length: 8 bytes consistently Output Data none © TR-Electronic GmbH 2002, All Rights Reserved Page 62 of 67 Printed in the Federal Republic of Germany TR - E - BA - GB - 0025 - 07 02/16/2011