The supervisory terminal lists each test as it is performed on the Network Module in the
following order:
NCL BOOT STARTUP TESTS
RAM - OK
PROM - OK
NCL STARTUP TESTS
UART - OK
ECP - OK
DATABASE - OK D2
RTC - OK
PLL - OK
NOTES: The "68020 - ERROR" message is displayed only if one of the 68020
CPU diagnostic tests fail.
The "DIP SWITCH 8 OFF" message is displayed only if DIP Switch
K1-8 on the Network Module is incorrectly set to the OFF/OPEN
position.
The "ERROR BATTERY" message is displayed only if one, or both,
batteries on the Network Module are defective or low in voltage.
●
If the Network Module self-test is satisfactory and passwords have been previously defined:
- Module comes online.
- Message, LINK/2 (or microLINK/2) Supervisory Port On-Line, appears on the supervisory
terminal.
- Password prompt (ENTER PASSWORD:) appears. See "Supervisory Port Log In"
paragraph.
After password is entered correctly:
- Time and date appear on the supervisory terminal.
- Prompt (Nxxxx>) appears. (xxxx is the local node number.)
●
If the Network Module self-test is satisfactory and passwords have not been previously
defined:
- Module comes online.
2-4