Adding Modules
In general, adding a module requires the following activities:
●
If a module must be removed or relocated before the new module can be installed, use the DEL
command to delete database entries for the module being removed.
●
Use the RMV and INS commands to logically remove and insert modules.
●
Define database parameters for the modules that have been added or relocated:
- For Interlink Modules, define intermachine link parameters and routing tables. See Tables
6-4 and 6-5.
- For Integrated Trunk Modules, define DS-1/E-1 parameters, bundle configurations,
proprietary and nonproprietary bundle parameters, channel connections, D-channel
parameters, and routing tables. See Tables 6-4 and 6-5.
- For Voice Processors, define DS-1/E-1 parameters, quality parameters, DS-0 channel
parameters, and channel connections. See Tables 6-6, 6-7, and 6-12.
- For Channelized Services Processors, define DS-1/E-1 parameters, quality parameters,
master DS-0 channel parameters, bundle configuration, and channel connections. See
Tables 6-8, 6-9, 6-10, and 6-12.
- For Voice Server Modules, use the SET VSM command to define the module.
- For I/O modules, define channel connections and parameters. See Tables 6-11 and 6-12.
- For X.50 Server modules, use SET XSM command to define the module, then define
channel connections and parameters. See Table 6-18.
For more detailed information on adding modules to an existing LINK/2+ System, see Installing
Additional Modules chapter in the LINK/2+ Installation and Maintenance Manual, which provides
step-by-step procedures covering the physical installation as well as the programming activities
required for each type of module.
L2UG
6/30/94
6-15