Download UM1080 - STMicroelectronics
Transcript
UM1080 4 On-the-fly Sensorless startup On-the-fly Sensorless startup The “On-the-fly” sensorless startup is a new algorithm able to detect if the motor is running before the startup and skip the acceleration phase if not necessary. If the motor runs with a speed that is above the allowed threshold, the firmware apply the FOC from the beginning, without need to stop it and re-start. This feature is particular useful for fan application. It is possible to enable this feature only when Sensor-less (Observer+PLL) or Sensor-less (Observer+Cordic) is selected in the Drive Management – Speed Position Feedback Management dialog. To enable this feature check the “startup on Fly” check box in the Drive management. Start-up parameters dialog like shown in Figure 5 and Figure 6. Figure 5. Enabling “On-the-fly” start-up with Basic profile DocID018802 Rev 6 15/53 52