Download IZAR@SET
Transcript
IZAR@SET Error table SHARKY 775 SHARKY 775 / SCYLAR INT 8 Error C-1 E1 E3 E4 E5 E6 E7 E8 E9 EA Eb EC Ed Error table SCYLAR INT 8 Error C-1 E1 E3 E5 E8 E9 EA Eb EC Ed -48- Error description Basic parameters saved in flash or RAM have been lost Temperature range exceeds (-9.9 °C ... 190 °C) Cause, Remedy Replace meter Error description Basic parameters saved in flash or RAM have been lost Temperature range exceeds (-9.9 °C ... 190 °C) Cause, Remedy Replace meter Sensor short-circuit, sensor break Replace sensor Forward and return sensor reversed Interchange forward and return sensor Hardware error Transducer defective or short-circuit Communication not possible Too frequent reading Increase interval for maximum values (see "Interval of maximum values" on page 35) Flow direction of flow meter incorrect Flow rate = 0 Check installation position and ensure correct installation No meaningful ultrasonic receive signal Air in the measuring path Defective primary voltage (only if mains Check primary voltage and enunit used) sure supply Supply from backup battery Battery nearly discharged Replace meter Leakage: Burst pipe detected Check pipes and connections, repair if necessary Leakage: Heat meter leak detected Check meter, replace if necessary Leakage: Leakage pulse input 1 Check pulse input 1 and repair leakage if necessary Leakage: Leakage pulse input 2 Check pulse input 2 and repair leakage if necessary Sensor short-circuit, sensor break Replace sensor Forward and return sensor reversed Interchange forward and return sensor Communication not possible Too frequent reading Increase interval for maximum values (see "Interval of maximum values" on page 35) Defective primary voltage (only if mains Check primary voltage and enunit used) Supply from backup battery sure supply Battery nearly discharged Replace meter Leakage: Burst pipe detected Check pipes and connections, repair if necessary Leakage: Heat meter leak detected Check meter, replace if necessary Leakage: Leakage pulse input 1 Check pulse input 1 and repair leakage if necessary Leakage: Leakage pulse input 2 Check pulse input 2 and repair leakage if necessary